0-20mA 0-10V analog output current and voltage generator 485 MODBUS isolation
0-20mA 0-10V analog output current and voltage generator 485 MODBUS isolation

0-20mA 0-10V analog output current and voltage generator 485 MODBUS isolation

Price:   $50.00

  • Model: ic0A852
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)
(complete orders today,deliverd around 26/04/2025)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    Aierwill Pure Sine Wave Inverter 12v 220v Dc To Ac 8000W 6000W 3000W 1600W Car Inverter Auto Power Converter For All Car home
    $643.92
    Pure Sine Inverter Automotive Inverter 12V To 220V, 1000w1600w2200w3000w LED Display Camping Emergency Inverter Conveter Tool
    $161.64
    Three phase fully isolated AC phase shift voltage regulator module 150A power regulator LSA-TH3P150
    $142.65
    Pure Sine Wave Inverter 1000W 2000W 3000W 4000W 5000W Power DC 12V To AC 220V Voltage 50HZ Converter for Home Car Inverters
    $530.20
    • Details
    • Reviews
    • Tags
    • FAQ
    Type:Logic ICs
    Condition:New
    Model:PD305X
    Item:1
    Color Classification:Key subtraction output 0-10V inputs with switches with switch 0-5V 0-1
    Renovation and construction content:Installation Engineering

    This link includes three kinds of modules: each with basic and enhanced , please take the time to explain
    1: 0-20mA 24V output load resistance of not more than 910 Euro
    2: 0-5V output , 0-10V output current is less than 7mA

    3: Key subtraction output

    1 Overview

    Based onRS485 Interface ,Modbus Analog output protocol control module.

    IsolationRS485Interface, supportModbus-RTU Agreement.

    2: Wide operating voltage :DC8V-30VPower reverse does not work. Using original MC34063A 38V switching power supply can work within , the power consumption is less than0.5W.

    Current output type:0-20mA (21mA MAX), The output voltage 12V, 24V.

    Voltage output type :0-5V,0-10V, ( can be customized 0-21V)

    OutputAccuracy : Standard12PositionDA, the error does not exceed 5 per thousand standard value .

    Optional DisplayLED:4Position0.36Inch red , direct display output value

    Dimensions:88 * 72 * 59

    Working temperature :-35~+50.

    Using standard35mmRail mounting .

    Application: analog output control, automatic control .

    Can be customized for a controlled waveform generator.

    Enhanced : Optional belt1-6Switch inputs and emergency preset settings.The state of the digital inputs can be used "IOModule communication tool " read.The basic model no such function .

    Key operation can type :INprefix = st1 1 IN2As the output of the key changes in the use of, IN3Rapid buttons.prefix = o

    Pressed aloneIN1OrIN2, Decrease or increase the output value0.01 (mA,V); Has been pressed2Seconds will change continuously.

    In caseIN3Press , then pressIN1OrIN2, Decrease or increase the output value1.00 (mA,V);

    Output value increased up to the maximum output capacity is no longer increased.

    Output value is reduced to0So far.

    Key connection as follows :


    Output through software correction , if you set the output value exceeds the maximum output capacity of the module , the maximum output value flashes .

    2 Common Interface Model Pictures and

    Models Pictures and the interface is as follows:

    A:RS485 Serial Communications A

    B:RS485 Serial CommunicationsB

    Power supplyV +: DC power positive

    Power supplyGND: DC power supply negative common

    +,-: Current or voltage output terminal

    DIx: Switch input forGNDShort said the switch is closed and the internal structure is as follows :


    3 Register information table and function code

    3.1 Function Code03H( Read)06H( Write )

    ParametersSetting registerInformation Sheet

    Word Address

    Byte

    Location

    Description

    Parameter Description

    Property

    10H

    Low8Position

    Communication Configuration

    Initial value:00

    BIT<7:5> Retention

    BIT<4:3>00 =No parity 01 =Even parity10 =Odd parity (11 =Odd parity )

    BIT<2:0>000 = 9600 001 = 1200 010 = 2400 011 = 4800 100 = 9600

    101 = 14400110 = 19200Other combinations are not defined , in accordance with9600Deal with

    RW

    High8Position

    Mailing Address

    Initial value:01

    Setpoint range= 1To 250

    Address0Broadcast address(If the value set for the communication program0Equivalent to1)

    RW

    11H

    Current output value

    Initial value:00

    Module current voltage or current output value , after the module power output will follow this value .

    The value is2Whether the sign -byte integerThe unit is :uA,mV.

    RW

    12H

    Low8Position

    Retention

    RW

    High8Position

    Retention

    RW

    13H

    Switch1Corresponding output preset value

    Initial value:00

    The value is2Whether the sign -byte integerThe unit is :uA,mV.

    For example:1285H = 4741d = 4741 (uA,mV) = 4.741 (mA,V)

    Description: The preset is set up after the occurrence of the input when the switch is closed , the output value will be forced to default immediately . If the value is0Is prohibited linkage between the switch and the output.

    Priority: When multiple input switch is closed , the switch has a higher number of high priority.

    When forced to lift output , will be restored to11HMeans the set value .

    Digital input status can be read "Running Status Register" get .

    RW

    14H

    Switch2Corresponding output preset value

    RW

    15H

    Switch3Corresponding output preset value

    RW

    16H

    Switch4Corresponding output preset value

    RW

    17H

    Switch5Corresponding output preset value

    RW

    18H

    Switch6Corresponding output preset value

    RW

    3.2 Function Code03H( Reading )

    The current operating statusRegisterInformation Sheet

    For word

    Site