Type:Logic ICs
Condition:New
Note: There is no constant temperature crystal oscillator (OCXO) in this distribution amplifier.
10M Frequency Distributor, Distributed Amplifier, 8-way Output,
10MHz Distribution amplifier, 8 port output
Power supply: DC11.7-12.9V, maximum 6W
POWER: DC11.7-12.9V, MAX: 6W
Input: 10M, 0.1Vpp-5Vpp
INPUT: 10M, 0.1Vpp-5Vpp
Output: 8 channels, all 1VRMS (13dBm)
OUTPUT: 8 PORT 1Vrms (13dBm)
Direction: PWR. Power Direction
EXT 10M: External 10M Output Indicator
ERROR: Light on, no output
LED: PWR: POWER
EXT 10M: extern 10M input
ERROR: not output
Annex: AC110-220V-DC12V/1.0A power adapter
Accessory: AC110-220V-DC12V/1.0A
Size: W*H*L=100*55*120 (including BNC part)
SIZE: W * H * L = 100 * 55 * 120 (include BNC connect)
Weight: Net weight 400 grams (excluding packaging), 600 grams (including transformers, including packaging)
Weight: 600g (net weight), 800g (include adapter, package)
Questions and Answers to Frequent Questions:
FAQ.
1. Question: What is a frequency divider, a distributed amplifier?
A: What is this
Answer: Frequency distributor divides a frequency into several frequencies. Distributed amplifier amplifies weak and small signals. Its main purpose is to use the whole way.
Frequency amplification with low signal amplitude is divided into multi-channel frequency output.
Q: This is a frequency distribution amplifiler and a OCXO frequency standard. input extern 10M
Then output 8 ports 10MHz
2. Question: Where is the main application?
A: any application
Answer: For example, there is a 10M benchmark, to provide a benchmark for five instruments, how to do, here you can use the amplifier.
Q: suc as there is a 10MHz frequency standard 1 port, but there is five equipment, how to do.
Used this distribution amplifiler
3. Question: What's the use of all three lights?
A: LED inductor
Answer: One is the PWR, which is the power indicator lamp. Once the power is connected, the lamp will turn on to check whether the power supply is good or not.
EXT 10M indicator light, which is on, indicates that the output is an external input signal.
ERROR lamp, the light is on, indicating no signal output or equipment failure, power on within 3 seconds, and power off within 3 seconds is not counted.
Q: PWR: power on,
EXT 10M: if input extern 10MHz, this LED on.
ERROR: if not output, this led on,