16 channelSwitch input and output IO module digital input and output modules switch module RS485 MODUBS
16 channelSwitch input and output IO module digital input and output modules switch module RS485 MODUBS
16 channelSwitch input and output IO module digital input and output modules switch module RS485 MODUBS

16 channelSwitch input and output IO module digital input and output modules switch module RS485 MODUBS

Price:  

  • Model: ic0A4522
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)
(complete orders today,deliverd around 26/04/2025)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    25184 7 Inch IPS LCD Capacitive Touch Screen LCD Module 7 Inch 1024*600 Raspberry Pi LCD Display
    $44.80
    25182 Cheap Price Snm01 High-Fidelity Studio Microphone Professional Condenser Mic For Recording
    $388.00
    25181 Low Price Good Quality High-Performance Live Broadcast Sound Card Sns01 Professional Audio Interface For Streaming 
    $300.00
    25183 Cheap Made in China Open on Ear Air Conduction Neckband Sport Blue Tooth Wireless Earbuds
    $59.80
    • Details
    • Reviews
    • Tags
    • FAQ
    Condition:New
    Type:Logic ICs
    Model:IOMxxxx
    Item:1
    Color Classification:4 switch into four switch 4 analog inputs 8 inputs , 8 outputs NPN 8 i
    Renovation and construction content:Hydropower Engineering



    1Outline

    IOMSeries Main Features

    Based onRS485Interface ,ModbusSwitch input and output control protocol module .

    IsolationRS485Interface, supportModbus-RTUAgreement.

    2: Wide operating voltage :DC8V-30VPower reverse does not work. Using original MC34063A 38V switching power supply can work within , the power consumption is less than0.5W.


    Using standard35mmRail mounting .


    Dimensions:88 * 72* 59

    Working temperature :-35~+50.

    Applications: HVAC , switch monitoring areas , digital output control , automatic control, remote telemetry .



    PDSeries main features ( listed only differs fromIOMPart of a series )

    10A 250VRelay outputs, each providing a normally open contact output. Output delay function can be set .

    Switch input for relay control . Switching mode can be set to move the type switching .

    Non-IsolatedRS485Interface, supportModbus-RTUAgreement.

    Power supply: DC12V,24VStatic power consumption of less than0.05W, Each relay power0.4W.


    2 Common product pictures and interfaces

    Models Pictures and the interface is as follows:

    A:RS485Serial CommunicationsA

    B:RS485Serial CommunicationsB

    Power supplyV +: DC power positive

    Power supplyGND: DC power supply negative common


    2.1 IOM1600:16Switch input

    IN1-IN16Is opto switch input , active low , the internal structure is as follows :




    2.2 IOM0016:16Switching outputs, NPN / MOSOutput Output tube model 2SC3647 SOT89 package

    DO1-DO16A switch output terminal ,NPN / MOSOutput, the output capacity of 2A 100V. Internal structure is as follows :

    Diode P6KE50A, may not be welded .







    2.3 IOM0804:8Switch input ,4Relay output

    DO1-DO2A switch output terminal , normally open relay contact output , output capacity3A250V AC.




    2.4 IOM0808:8Switch input ,8RoadNPN / MOSExport




    2.5 PD8055:5Opto-isolated switch inputs ,5Road 10A 250VNormally open relay output


    2.6 IOM0404-4AI: 4 digital inputs , 4 digital outputs , 4 analog inputs


    3RegisterInformation tables and function code

    3.1Function code03H( Read)06H( Write )

    ParametersSetting registerInformation Sheet


    Word Address

    Byte

    Location

    Description

    Parameter Description

    Property

    10H

    Low8Position

    Communication Configuration



    Initial value:00

    BIT<7:5> Retention

    BIT<4:3>00 =No parity01 =Even parity10 =Odd parity (11 =Odd parity )

    BIT<2:0>000 = 9600001 = 1200010 = 2400011 = 4800100 = 9600

    101 = 14400110 = 19200Other combinations are not defined , in accordance with9600Deal with

    RW


    High8Position

    Mailing Address

    Initial value:01

    Setpoint range= 1To 250

    Address0Broadcast address(If the value set for the communication program0Equivalent to1)

    RW

    11H

    Low8Position

    Round objects enable significant


    Initial value:255

    Alternately display enable bit correspondence :

    BIT0:KIN1VersusOUT1BIT 1:KIN2VersusOUT2

    BIT 2:KIN3VersusOUT3BIT 3:KIN4VersusOUT4

    BIT 4:KIN5VersusOUT5BIT 5:KIN6VersusOUT6

    BIT 6:KIN7VersusOUT7BIT 7:KIN8VersusOUT8

    BITBits1Displayed when the corresponding value ;0When not displaying

    If set to00H, Then withFFHEquivalent .

    RW

    High8Position

    Round display switching interval

    Initial value:05

    Setpoint range= 0To255( Sec )

    If set to00H, Then with01HEquivalent .

    RW

    12H

    Low8Position

    Article1Switch input control mode

    Initial value:00

    See Note


    RW

    High8Position

    Retention


    RW

    13H


    Article2Switch input control mode

    Ditto

    RW

    14H


    Article3Switch input control mode

    Ditto

    RW

    15H


    Article4Switch input control mode

    Ditto

    RW

    16H


    Article5Switch input control mode

    Ditto

    RW

    17H


    Article6Switch input control mode

    Ditto