2088 passive 2-wire meter head 4-20mA temperature and pressure tabs display table header Percent Display
2088 passive 2-wire meter head 4-20mA temperature and pressure tabs display table header Percent Display
2088 passive 2-wire meter head 4-20mA temperature and pressure tabs display table header Percent Display

2088 passive 2-wire meter head 4-20mA temperature and pressure tabs display table header Percent Display

Price:   $23.29

  • Model: ic0A939
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)

Please Choose:

  • PCR032038 20x40
  • PCR64324 40x40
  • PCR064270 40x40
  • PCR064200 40x40
  • PCR064088 40x40
  • PCR064141 40x40
  • PCR064076 40x40
  • PCR064257 30x30
  • CR0064152 30x30
  • PCR064115 30x30
  • PCR064165 25x25
(complete orders today,deliverd around 25/04/2025)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    DC CC 9A 150W 300W Step Down Buck Converter 5-40V To 1.2-35V Power module
    $3.10
    Four Channel 4 Channel Way Route MOSFET Button IRF540 V4.0+ MOSFET Switch Module For Arduino DC Motor Drive Dmimmer Relay Board
    $2.20
    1set 2 DOF Short Pan And Tilt Servos Bracket Sensor Mount Kit For Compatible MG995 Wholesale Retail
    $2.15
    Industrial-grade semiconductor refrigeration film hot and cold module TEC 12x12 beauty instrument chip refrigeration diy
    $22.69
    • Details
    • Reviews
    • Tags
    • FAQ
    Condition:New
    Type:Logic ICs
    Model Number:2088
    Model:PD2088
    Item:1
    Color Classification:2088 with a silicone rubber shell mask with 10cm lead bare boards 0.56
    Renovation and construction content:Hydropower Engineering

    1, the two -line intelligentLEDHeader specification (4-20mA)

    Outline

    Two -line intelligentLEDHeader, microprocessor andTwenty fourPositionADAchieve high-precision instruments. Two lines4-20mACurrent input ,4Bit HighlightLEDShow that the accuracy of plus or minus0.2%.The meter does not need to reprovision the power supply , only by the transmitter ( pressure , weight, temperature, etc. ) output4-20mASignal inputs can be displayed directly ;

    By two programming buttons , can be achieved4-20mAEnter the correspondingLEDDisplay , in-1999To9999Scope any adjustments.

    Widely used inSuch as: pressure transmitter, power transmitter, temperature transmitters, etc. , can also be used in instrumentation, teaching equipment , power electronics, industrial automation and control equipment, medical equipment , AC-DC power supply, teaching equipment , etc., as DC parameter display components , improve product quality , for the pointer instrument replacement product .

    Meter can determine its own variety of units : Temperature (), the percent sign ( % ) , pressure (KPa,MPa) ;

    Small Dimensions :PCBBoard positioning hole .

    Connection is simple : the first two lines of the table directly with the pressure, temperature , humidity and other output lines of the transmitter can be connected in series .

    Can be customizedOrange, blue , emerald greenDigital pipe ;

    Technical parameters

    1 .Power supply:DC4-20mASignal source , the pressure drop is inserted<3.5V2.Drift :50PPM(Custom made25PPM,5PPM)

    3.Display range:-1999-99994.Accuracy : ± (0.2% FS + 1Words)

    5 .Working current:1mA - 24mA6.Working temperature :-20prefix = St1 -70

    7 .Humidity : ≤85% RH8 .Display character height :0.36,0.56InchLED

    9.Dimensions: see below .prefix = o

    10 .Two alarm points, below the lower limit or above the upper limit alarm, flashing display(Alarm switch= ON)( Comments1).

    11 .Automatic range switching function : automatically move the decimal point position data can be displayed with the most digits , similar to multimeter automatic shift .

    For example:

    A decimal , enter 1.234 , can be displayed as " 1.234 " ( decimal point automatic range switching = ON) or " 1.2" ( decimal point automatic range switching = OFF).
    Two decimal places, enter 1.234 , can be displayed as " 1.234 " ( decimal point automatic range switching = ON) or " 1.23 " ( decimal point automatic range switching = OFF).



    2088Bare board price :30;

    2088Band shell beltPVCFilm Price:33

    Dimensions

    2088Transmitters withHirschmann connector with transmitterCabinet table with the mounting panel

    Display character height :0.36InchDisplay character height :0.36InchDisplay character height :0.36Inch



    Dimensions

    For 2088 transmitter Display word height: 0.36 inch Panel size: diameter 38mm Chassis size: diameter 48mm Fixing method: screw fixing the chassis




    Description :( Comments1) , Under the independent power of three-wire mode , the alarm can be customized with two actual product output pin , the output optocoupler or relay.








    Parameter Description

    1: Zero setting : "ZERO" Range-1999-99992: Full scale setting: "FULL" Range-1999-9999

    3: Decimal point position: "DOT ",Value "--- ." , "--.-" , "-.-" , ".---"

    4: Filtering parameters : "DAP "Scope0-165: Alarm switch : "HILO" Value "ON ""OFF"

    6: Lower limit alarm point : "STPL" Range-1999-99997: Limit alarm point : "STPH" Range-1999-9999

    8: Lower limit alarm direction : "LDIR"Value "DN" , "UP"9: Limit alarm direction : "HDIR"Value "DN" , "UP"10: Alarm output delay: "DELA" Range0-25011: Automatic range switching: "AUTO" Value "ON ""OFF"

    Note:If the user does not specify , does not offer this feature.Alarm direction ,"DN"Is the index value is less than alarm , alarm ."UP" Index value is greater than the alarm point , alarm.





    2 ,3: DC4-20mAThree -line header,75mVOr othermVLevel full-scale voltage meter head

    If the user has can provide power to the header , or need to measure other large, small value of current or voltage , then mining

    With a three -wire connection .There are two practical customizable alarm pin products , optocoupler or relay output .

    If the user input signal is very small , such as75mVFull scale ( pressure sensors, etc.) , the first table using a precision op amp amplifies ensure a high enough resolution.

    Outline

    Reference"Two Line SmartLEDHeader . "

    Technical parameters

    Power supply:DC2.7V-5VHigherLEDThe brighter , not to exceed5.2V.2.7VCurrent work is about7mA,5VAbout31mA,If you have requirements for power, need to explain .

    Other Reference "Two -line intelligentLEDHeader"

    Common specifications

    4-20mAMeasurement ;0-5VMeasurement ;0-10VMeasurement ;0-36VMeasurement ;0-150VMeasurement ;0-75mVMeasurement.



    4: Two-wire DC voltmeter(3V-30V,12V-150VEnter)

    The header part of the "two -line intelligentLEDHeader "derivative products , the use of voltage inputConstant current power supply to the meter . This product is different from the low-cost market3Bit products displayed .

    The voltmeter wiring simple, just connect the two lines in the table there is reversal protection , reverse does not burn .

    The voltmeter can be used for motorcycles, cars and other monitoring battery voltage , battery status grasp . Can also be used for other voltage measurement purposes .

    Outline

    Reference"Two Line SmartLEDHeader . "

    Technical parameters

    Electrical workSource:DC3V-30V,12V-150VBoth , constant current7mAPowered by.

    Other Reference "Two -line intelligentLEDHeader"




    5 ,6,7: AC two wire voltmeter , ammeter head

    The header part of the "two -line intelligentLEDHeader " derivative products, use a capacitor step-down principle to solve the supply , because the higher the frequency the smaller the impedance of the capacitor , it is not suitable for use in high-frequency electronic speed control, or other high-frequency components of the occasion, or easy to burn!!!.

    Outline

    Reference"Two Line SmartLEDHeader . "

    Technical parameters

    Electrical workSource:AC75V-300V,AC100V-500VBoth.

    Other Reference "Two -line intelligentLEDHeader"

    Measuring range : Measuring Voltage is working power ;

    Measuring current is divided into:0-15.00A,0-50.00A,0-120.0A,0-250.0A, Mandrel transformer access .



    User manual

    Principle:

    The display value (Y) of the header is actually the process of linear conversion between the AD sampling (X) value and the display value (Y).

    The table header is calculated according to the formula: y=k*x + b.

    Two points are needed to determine k, b. These two points are (zero AD, zero display ZERO), (full scale AD, full scale display FULL).

    Therefore, the use of the meter header is divided into two steps: one is calibration, and the other is display setting


    The first step: the calibration of the meter head is to save "zero AD" and "full scale AD".

    Taking the 4mA-20mA meter head as an example, the calibration method is as follows:

    1: The meter head is connected to 20.000mA (4mA) stable current, press S1+S2 keys at the same time to enter the main menu.

    2: Press the S1 key, "20NA" ("4NA") appears, and then press the S1+S2 key at the same time to enter the calibration menu.

    3: Enter the password "<?xml:namespace prefix = st1 />1234", and press the S1+S2 keys at the same time.

    4: The LED display value is one-sixteenth of the current AD sampling value. When the display is very stable, press S1+S2 keys at the same time to save the 20mA (4mA) AD value and exit the calibration menu.

    5: 20.000mA corresponds to the "20NA" menu; 4mA corresponds to the "4NA" menu.


    Step 2: The display settings are to save "ZERO display at zero" and "FULL display at full scale".

    For example: 4mA shows -50.0, 20mA shows 150.0

    1: The meter head is connected to 20.000mA stable current, press S1+S2 keys at the same time to enter the main menu.

    2: Press the S1 key, "ZERO" ("FULL") appears, and then press the S1+S2 key at the same time to enter the setting menu.

    3: Press the S1 and S2 keys (the digit to be set is flashing) to set the value to "-50.0" ("150.0"), then press S1+S2 at the same time to save and exit the setting menu.

    4: "ZERO display at zero" corresponds to "ZERO" menu; "Full scale display FULL" corresponds to "FULL" menu.


    The first step has been calibrated at the factory, and the second step needs to be set by the user. By default, 4 and 20 are displayed, which is the current value.


    Other settings

    Decimal point position: "DOT", value "---.", "--.-", "-.—", ".---"

    Filter parameter: "DAP", the range is 0-16, if the value jumps too much, increase the value appropriately, the data will be smooth.

    Automatic range switching: "AUTO", the value is "ON", "OFF"