Price:   $46.89

  • Model: ic0A232
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)
(complete orders today,deliverd around 18/04/2025)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    10pcslot IRGP20B60PD GP20B60PD IGBT 600V 20A TO247 Free shipping
    $11.10
    100% test DDR6 K4ZAF325BM-HC14 K4ZAF325BM-HC16 K4Z80325BC-HC14 K4Z80325BC-HC16 D8BGX D8BGW D8BWW D9WCW D9WGB D9WZX BGA Chipset
    $15.66
    5PCS MAX5980GTJ+T MAX5980G 5980G QFN32
    $16.90
    (5piece)100% New IT8528E AXA AXS EXA EXS FXA FXS QFP-128
    $10.88
    • Details
    • Reviews
    • Tags
    • FAQ
    Brand Name:icchipcn.com
    Condition:New
    Type:Logic ICs
    Model Number:32DI

    Chapter product introduction

    1、 Product overview

    MBSL32DIThe module is a 32-channel digital quantity isolation input module, which is output through RS485 interface. The module adopts standard Modbus RTU communication, which can be directly adaptedVariousupper computer configuration software, PLC, DCS, etc. The modular power supply adopts industrial design standards, which effectively inhibits all kinds of serial mode and common mode interference, and at the same time ensures the stable and reliable operation of the module.

    1,Adopting RS485 MODBUS RTU standard communication, it can be networked with upper computer configuration software, PLC, industrial touch screen, etc,with communication status indicator light

    2, signal control, power supply, RS485 communication electrical signals are isolated from each other.3, communication circuit adopts lightning protection, anti-interference design,power polarity protection.

    4, RS485 communication signal output interface adopts overvoltage and overcurrent dual protection.

    5Can be widely used for signal acquisition and control of industrial field equipment.

    6. Communication format can be set by software.

    II. Main technical indicators

    project

    technical indicators

    signal input/output

    1. Input channel: 32 digital input channels

    communication output

    1. Communication protocol: MODBUS-RTU

    2. Interface type: isolating RS485 communication, the output interface adopts overvoltage and overcurrent dual protection

    3. Baud rate: 4800bps, 9600bps, 19200bps, 38400bps, 57600bps, 115200 bps

    4. Check bit: no check, even check, odd check

    5. Setting mode: module address, baud rate and parity can all be set by software

    6. Communication distance: @ 9600bps 1200 m

    module size and installation method

    1. installation method: Standard DIN rail installation or screw installation

    Two. Overall dimensions: 125 × 90 × 43mm

    working environment

    temperature:-10~+60humidity: 35~85%(No condensation)

    working power supply

    1. Electric voltage: 12V ~ 30V wide range, with power polarity protection

    2. Power consumption: less than 5W

    III. Interface Definition

    terminal name

    Explain

    terminal name

    Explain

    PW+

    external power input positive end

    485A

    RS485signal A +

    PW-

    external power input negative terminal

    485B

    RS485signal B-

    I00

    digital quantity input channel1

    I20

    digital quantity input channel17

    I01

    digital quantity input channel2

    i21

    digital quantity input channel18

    I02

    digital quantity input channel3

    I22

    digital quantity input channel19

    I03

    digital quantity input channel4

    i23

    digital quantity input channel20

    I04

    digital quantity input channel5

    i24

    digital quantity input channel21

    I05

    digital quantity input channel6

    i25

    digital quantity input channel22

    I06

    digital quantity input channel7

    I26

    digital quantity input channel23

    I07

    digital quantity input channel8

    i27

    digital quantity input channel24

    I10

    digital quantity input channel9

    I30

    digital quantity input channel25

    I11

    digital quantity input channel10

    I31

    digital quantity input channel26

    I12

    digital quantity input channel11

    I32

    digital quantity input channel27

    I13

    digital quantity input channel12

    I33

    digital quantity input channel28

    I14

    digital quantity input channel13

    I34

    digital quantity input channel29

    I15

    digital quantity input channel14

    I35

    digital quantity input channel30

    i16

    digital quantity input channel15

    I36

    digital quantity input channel31

    I17

    digital quantity input channel16

    I37

    digital quantity input channel32

    com

    public Terminal+

    com

    public Terminal+





    • schematic diagram of module wiring


    chapter IIModbusregister and communication protocol description

    I.MODBUS function code and address range of the module

    1. MODBUS function code of the module

    register type

    address range

    function Code

    function Code description

    operation

    hold register

    40001-40016


    0x03H

    read multiple hold registers

    read the values of one or more hold registers

    0x 06H

    write a single hold register

    write a data into the hold register

    0x 10H

    write multiple hold registers

    write one or more data into the hold register

    input digital quantity

    10001-10032

    0x02H

    read input discrete quantity

    discrete input register

    II. Register definition description

    1.Hold register (function code:0x03H,0x06H,0x10H)

    address

    parameter

    length?

    read/write

    minimum value

    value

    Explain

    40001

    di(1~16)

    2

    read-only

    0

    0xffff

    read the status of the 16-digit input

    40002

    di(17~32)

    2

    read-only

    0

    0xffff

    read the status of the 16-digit input

    40003

    device address

    2

    read/write

    1

    255

    1(default)

    40004

    Baud rate

    2

    read/write

    1

    5

    1(4800) 2(9600)default3(19200) 4(38400) 5(57600) 6(115200)

    40005

    check digit

    2

    read/write

    1

    3

    1 (no verification).default?2 (odd check) 3 (even check)

    40006

    spare

    2

    read/write

    0

    1


    40007

    product Version

    2

    read-only

    0

    --

    year?+Month+day

    40009

    spare

    2

    read/write

    0

    0xffff


    400010

    spare

    2

    read/write

    0

    0xffff