4816 channel K thermocouple acquisition board, input module, thermocouple temperature transmitter, MODBUS protocol, RS485
4816 channel K thermocouple acquisition board, input module, thermocouple temperature transmitter, MODBUS protocol, RS485
4816 channel K thermocouple acquisition board, input module, thermocouple temperature transmitter, MODBUS protocol, RS485
4816 channel K thermocouple acquisition board, input module, thermocouple temperature transmitter, MODBUS protocol, RS485

4816 channel K thermocouple acquisition board, input module, thermocouple temperature transmitter, MODBUS protocol, RS485

Price:   $102.65

  • Model: ic0A182
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)

Please Choose:

  • orange
  • Red
(complete orders today,deliverd around 26/04/2025)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    2pcs Soil temperature and humidity sensor SHT10 SHT20 greenhouse flower nursery
    $35.68
    DC-DC SX1308 Step-UP Adjustable Power Module Boost Converter
    $0.32
    SHT30 Shield for D1 mini SHT30 I2C digital temperature and humidity sensor module
    $1.08
    Brand new Double Side 5x7 cm Prototype Glass Fiber Thin PCB Board
    $0.67
    • Details
    • Reviews
    • Tags
    • FAQ
    Type:Logic ICs
    Condition:New
    Model Number:PK9022
    Model:PK9019
    Color classification:8 Channel,4 channel

    I. main performance profiles:

    The module can measure 4/8/16 way K graduation (or J, T, E, R, S, B, etc.) thermocouple signals, modules can be applied to temperature measurement system. Its output is 485 bus mode, MODBUS-RTU communication protocol, which is convenient for PLC and configuration software applications.

    Two, module main parameters

    Operating voltage: DC8 to 24V, with power polarity protection, maximum 1200mW

    Communication interface: RS-485 interface, two-wire system, + 15KV ESD protection

    Communication speed: 1200 ~ 19200bps, software settings

    Communication format: 1 bit start bit, 8 bit data bit, 1 bit stop bit, no parity bit

    Transmission distance: <1200M (19200bps)

    Module address: 00 ~ 255 software settings

    Input signal: 8 way K graduation (or J, T, E, R, S, B) and other thermocouple signals

    Measuring accuracy: 0.5

    Measuring range: J:0 to 1200 DEG C; K:0 to 1300 DEG C; T:0 to 400; E:0 to 1000; R:0 to 1700; S:0 to 1768; B:0 to 1800 DEG c;

    Input isolation: signal input and communication interface output isolation, isolation voltage 1000VDC

    Sampling rate: 0.15S per channel, 8 channel cycle measurement

    Overall size: * * width * height = 122*72*43 unit: mm

    Installation: 35mm DIN rail clamping

    Working conditions: -20, ~70, 35%~85%RH, no condensation

    Three, module RS-485 communication instructions

    The 1. module uses standard MODBUS-RTU protocol to facilitate the connection of PLC and configuration software.

    2. the bits of each byte in the protocol: 1 start bits, 8 data bits, no parity bits, and 1 bit stop bits. Using CRC-16 check.

    3. function code 04H: read hold register, read measurement data

    Data start address range: 0100H to 010FH

    Data Description: read 32 bit data, low word in front, high word in back.

    Temperature data format description: one temperature data for 4 bytes, a total of 32bit (here 16 high, 0 has been), the actual temperature = reading measurement value /65536* range, the unit is: temperature