4-96S Strings Battery Protection Board LiFePO4Lithium TernaryLithium Titanate Battery Manage System BMS
4-96S Strings Battery Protection Board LiFePO4Lithium TernaryLithium Titanate Battery Manage System BMS
4-96S Strings Battery Protection Board LiFePO4Lithium TernaryLithium Titanate Battery Manage System BMS
4-96S Strings Battery Protection Board LiFePO4Lithium TernaryLithium Titanate Battery Manage System BMS
4-96S Strings Battery Protection Board LiFePO4Lithium TernaryLithium Titanate Battery Manage System BMS

4-96S Strings Battery Protection Board LiFePO4Lithium TernaryLithium Titanate Battery Manage System BMS

Price:   $402.95

  • Model: ic0A1594
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)
(complete orders today,deliverd around 11/07/2024)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    4PCS SW601 601 Power Light Board Extension 5V Colorful Power LED Strip Light Board for F722S RC Drone
    $8.85
    CH341A 24 25 Series EEPROM Flash BIOS USB Programmer Module + SOP8 Test Clip +1.8V adapter + SOIC8 SOP16 to DIP8 adapter DIY KIT
    $12.52
    USB3300 USB HS Board Host OTG PHY Low Pin ULPI Evaluation Development Module Kit
    $9.03
    ZVS induction heating machine quenching melting crucible melting DC30-75v high power 1-2Kw electromagnetic high frequency 220V
    $122.48
    • Details
    • Reviews
    • Tags
    • FAQ
    Brand Name:icchipcn.com
    Condition:New
    Type:Logic ICs

    Our solution is very flexible for the number of strings, and we can increase or decrease it ourselves;

    The system runs independently and is a passive system, the host does not need to move, the number of acquisition modules is automatically identified, and it cannot communicate with other inverters;

    Every time there are more than 12 strings, an acquisition module can be added, and all protection parameters can be set freely. As long as the battery voltage is within 5V, it can be used;

    There is no limit to the battery type, and different protection parameters can be modified to match different types of batteries;

    Flexibility is very high;



    Shipping List on the pciture is option: ?Host*1pcs, ?Acquisition Module*7pcs

    (Different option has with correcspondent cables and Cureent transfer)

    Each acquisition module can be connected to a maximum of 12 strings, 12x8=96 strings, as long as the total voltage is within 1000v, it can be extended in series.

    1. Real-time monitoring of 4-96 series single-cell voltage, which can be cascaded infinitely. At present, the host only supports 8 modules. Modularization is adopted. , so the total voltage of the batteries connected in series with a single module cannot be less than 11v. If the battery is less than 12 strings, the redundant detection channels must be connected in parallel to the positive pole of the highest battery of the module), and the total voltage of a single module input in series shall not be higher than 75v, the detection range of a single channel is 0--5v, and the input voltage of the host control part should not exceed 60v.

    2. Monitor the total voltage, charge and discharge current, power, temperature of the battery pack in real time and count the actual charge and discharge capacity in ah. The host has a temperature detection to monitor the temperature of the mos tube, and each module comes with a temperature detection, a total of 9 temperature detections.

    3. With overshoot, over-discharge, over-current, over-temperature protection.

    4. Display the percentage of remaining capacity in real time and display it with a progress bar.

    5. High voltage 200V rated long-term working current is 30A, instantaneous short-time 60A, low-voltage rated continuous working current is 70A, instantaneous short-time 100A, high voltage and current can use relay scheme, details can be discussed in detail, long-term constant high current The work needs to strengthen the heat dissipation of the mos tube.

    6. Running flashing indication, prompting the system running status, 3.5-inch IPS color display, ultra-wide viewing angle, the working status is clear at a glance.

    7. With the current manual calibration function, because the voltage measurement error is 1.2mv total measurement error, so no calibration is required.

    8. The charging and discharging are designed with the same port to reduce the connection line.

    9. The number of connection strings is expanded by module cascade connection, which can theoretically be expanded infinitely. Two-core cat5 twisted pair is used to connect the host and the module, and the communication between the module and the module, and the cable length can reach 40 meters (this length is the laboratory The effective length of the actual test in the environment, if the field interference is large or the wire selection is not suitable, the communication distance should be shortened accordingly).

    10. After the host is turned off, the module automatically goes to sleep, and the power consumption is only 4ua. The modularization can also shorten the length of the balance line, so that the host and the module, and between the module and the module can be placed at a long distance.

    11. The module has an automatic balancing function, which is balanced until the voltage drop stops at 0.001v, and the balancing current is 200ma. This function must be turned on after the battery is fully charged. Balanced discharge will generate a lot of heat, so you need to pay attention to the heat dissipation of the module.

    12. Fully isolated design, all interfaces can be hot-swapped, and the temperature sensor can be disconnected if it is not used.

    13. If you think the alarm buzzer sound is small, you can tear off the sticker on the surface, and the sound will be loud.

    The two-layer board of the main board is superimposed, the size is 135x57mm, and the thickness of the stack is 45mm, excluding the size of the radiator.

    Module size 82x72mm, stack thickness 13.8mm

    14. Using Bluetooth 4.0 to connect with the mobile APP, all parameters are clear at a glance, and the host parameters can be modified through the mobile phone

    15、After the input terminal is connected to the charger, it will automatically enter
    the charging state, and count the actual capacity, and display the charging current
    and power at the same time. With the increase of the charging capacity, the
    originally used capacity will gradually reduce, and the progress bar will act
    synchronously with the change of capacity.

    16、The BMS supports mobile app, which monitors and controls any status and
    parameters of the host through Bluetooth. When protection occurs, the mobile
    phone has the query of protection history, and the reason for the last protection can
    be queried.

    17、At present, the host has 14 tube version, 28 tube version and relay
    version. The relay version supports two connection methods of the same
    port and the separate port, and supports the use of Hall current sensor。

    18、The BMS has automatic control function of charge and discharge.
    After charging protection, as long as the discharge current is detected to
    be greater than 200mA, the charging port will be opened automatically
    to prepare for the next charging. After discharging protection, if the
    current of charging equipment is detected to be greater than 200mA, the
    discharge channel will be opened automatically, and the whole process
    will be completed automatically. In case of safety problems such as
    over-current protection, over-temperature protection and wrong

    number of battery strings, The charge and discharge MOS tube is closed
    at the same time. At this time, the channel must be opened manually
    after troubleshooting.

    19、The host instrument displays the current supported range, the
    maximum current is 999.9a, the maximum capacity is 6500ah, and the

    maximum power is 65000w







    1. Setting column, setting the minimum discharge protection voltage, the
    maximum charge discharge current, the total capacity of the battery and
    the number of battery strings

    2. Set charging cut-off protection voltage and protection temperature

    3. The system operation flashes, and the opening of the charge discharge

    channel is yellow, and the closing is red

    4. Temperature detection of 8 modules

    5. Indicator bar and percentage of remaining power

    6. Actual remaining capacity

    7. Actual charging capacity

    8. Host MOS tube temperature

    9. Function status and Protection Tips








    Note 1:When the battery pack is 16, the spare ports must all be short
    circuited to the positive pole of the last battery of the module, the

    specific connection is as follows:


    Note2:When the number of battery cells is 13, 14, 15, 25, 26, 27, 37, 38,
    39, the power supply voltage of a single module must be 11V. For lithium
    iron phosphate and lithium ternary, it must be up to 4 to make the
    Host power input 8-60v
    Charge discharge
    input and output

    module work normally, and all channels not used by each module must
    be parallel connected to the positive pole of the last battery of the

    module, The wiring diagram is as follows:


    In addition to the above special cases, other combinations can be
    connected from low position to high position successively



    Attention: Relayand the High-power Diode module in the picture are Not included. This should be purchased by yourself according to the current and withstand voltage.




    Mobile Phone APP Interface: