Brand Name:icchipcn.com
Condition:New
Type:Logic ICs
No.:ZL-524
Color classification:0-20MA,4-20MA,0-5V ,0-10V
Decoration and construction content:Hydropower project
1, RS485/RS232 dual serial analog input acquisition; 2, the original TI 16 bit AD chip, the accuracy higher than 0.1% (1/1000); 3, 3000V 4, with isolation voltage isolation; 24V voltage output two-wire, three wire output are available.
Please Choose : 0-20ma ,4-20mA , 0-5V , 0-10v.default is 0-10V.
ZL-524Is a four analog signal acquisition transmitter module.
1And the second generation of Mornsun 3000V isolation voltage module, better performance. Isolation voltage 3000V, more secure;
2Super high speed optical coupling chip, meet the communication requirements of high baud rate;
3Dual serial port circuit, the use of multi-level protection cascade (TVS+RC filter), all for the design of industrial environment;
4General guide rail housing, the use of more convenient;
5+7~32V DC voltage supply input, anti - Anti - ground protection;
6Output, perfect protection simulation, 1000V anti intrusion protection, anti surge plus 600W tube TVS;
7Standard MODBUS-RTU interface, to adapt to all the PLC module connection;
8Imported original 4 ADC 16 bit TI chip;
9Baud rate range: 300 ~ 115200bps (also more special requirements please);
10, all industrial design, to ensure that the use of new imported chips; temperature range: -40 degrees to 85;
11Optional OLED, LCD screen, display the address, baud rate, data bits, stop bits, parity bit,4 channel acquisition value;
1224V DC output, convenient for the second line, three wire transmitter power supply.
13, the power indicator lamp, communication indicator light.
Power supply voltage | VDC +7~32 |
communication interface | RS485/RS232 (MODBUS-RTUAgreement) |
baud rate | 300-115200(can be set) |
Postal address | 1-250(can be set) |
Input signal | 4-20mA0-20mA, 0-5V, 0-10V (optional) |
output signal | RS485With RS232 |
Equipment operating temperature | -20~60C |

input | transportenterRange | Resolution power | Accuracy | Explain |
Electric current | 0.000~22.000mA | 0.001mA | .0.005 mA | Sampling resistance 100 ohm |
Voltage | 0.000~-12.000V | 0.001V | .0.005V | Impedance 100K |
Port name | Connection content | Port name | Connection content |
VCC | Module power supply positive pole | 24V+ | 24VDirect current |
GND | Module power supply negative pole | 24V+ | 24VDirect current |
485- | RX485Negative end B- | AI1- | Channel 1 input negative |
485+ | RX485Positive end A+ | AI1+ | Channel 1 input positive |
GND | RX485land | AI2- | Channel 2 input negative |
RXD | RX232receiving end | AI2+ | Channel 2 input positive |
TXD | RX232Sending end | AI3- | Channel 3 input negative |
GND | RX232land | AI3+ | Channel 3 input positive |
GND | Reset terminal | AI4- | Channel 4 input negative |
CFG | Reset terminal | AI4+ | Channel 4 input positive |
ZL-5xType analog signal transmitter supports MODBUS-RTU function code 03 and two 06 kinds of function code.
For example, channel 1 of the channel 1 analog output, that is, write the register 4x0000, the order is as follows:
01 | 06 | 0001 | 01 F4 | D8 1D |
Equipment number | Write function | Register address | Register value | check |
Among them, the set of analog data is 1388, that is, 0x1388, decimal number is 5000, then the output value of I=5000/1000 = 5; 84 9C is 16 Decimal value,
CRC-16 (BISYNCH, polynomial is x16 + x15 + x2 + 1 shield word for 0A001H)
Cyclic redundancy algorithm is obtained. Please refer to the MODBUS for further information about the algorithm.
The returned data should be:
01 | 06 | 0001 | 01 F4 | D8 1D |
Equipment number | Write function | Register address | Register value | check |
lRead register --03
Read 2 device channel 1 and channel 2 of the current input value, 0x0005, 0x0006 two Register commands are as follows:
02 | 03 | 0005 | 0002 | D4 39 |
Equipment number | Read function | Register address | Register number | check |
Return data:
02 | 03 | 04 | 013202 2A | E9 BF |
Equipment number | Read function | Number of bytes | data | check |
Among them, the channel 0132 is the value of 1 0x0132, decimal number is 306, then the input value is 306/1000 = 0.306, the same calculation method,
Can calculate the channel 2 input values.