8 channel isolated 4-20mA0-5V0-10V±5V±10V analog output module RS485 MODBUS

8 channel isolated 4-20mA0-5V0-10V±5V±10V analog output module RS485 MODBUS

Price:   $77.87

  • Model: ic0A354
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)
(complete orders today,deliverd around 23/04/2025)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    icchipcn@hotmail.com
  • New Products
    New Arrival Portable 7 Port USB Hub High Speed USB 2.0 Dual Chip Splitter Adapter With AC Power Adapters For PC Laptop
    $11.76
    GEV new energy high voltage DC contactor coil 1224V relay 900V250A with auxiliary signal GEV250H-AANS
    $45.72
    NEW ORIGINAL SCII HIGH VOLTAGE DC RELAY CONTACTOR LEV100-12HD WITH ASSISTANT CONTACT
    $55.25
    USB 3.0 Switch Selector KVM Switch 5Gbps 2 In 1 Out USB Switch USB 3.0 Two-Way Sharer For Printer Keyboard Mouse Sharing
    $12.35
    • Details
    • Reviews
    • Tags
    • FAQ
    Condition:New
    Type:Logic ICs
    Model Number:MB8AO+


    O1CN01YTltum1j4ITVDgjCl_!!52134494



    I. Overview



    MB8AO +8the analog output module can output 8 analog signals of 0-20mA, 4-20mA, 0-5V, 0-10V, ± 5V and ± 10V, the output signals of each channel can be configured separately, which is very suitable for industrial sites with complex signal specifications; 8 analog output channels can be controlled through the isolation RS485 interface; The module adopts Modbus-RTU communication, it can be directly adapted to PLC, DCS and various domestic configuration software, etc.



    Signal output and power supply are isolated from RS485 communication electrical signals, which effectively suppress all kinds of serial mode and common mode interference, ensure the degree of data and ensure the reliable operation of the module at the same time.



    II. Characteristics




    1. standard Modbus-RTU protocol is adopted.


    2. According to their own needs, the output signal type of each channel can be set through configuration software.。


    3. The signal output type adopts non-jumper design, which can be set by testing software without opening the shell to set jumper, which is very convenient for users to use.。


    4. Unique AO analog output working mode



















    module function mode




    functional Features




    power-on load preset value mode




    analog outputAOthe initial power-on value can be set to load a value, which is loaded by default0value. It is mainly used in some occasions that a preset value is required for power-on, for example, a certain opening degree is required for the valve after power-on.




    Power-on load power-down value mode




    uninterruptedly monitor the power condition of the module. When the power failure of the module is detected, record and save the currentAOthe output value of the channel. When the module is powered on again, the analog outputAOload the value before the last power failure. It is mainly used for sudden power failure on site and automatic maintenance of on-site use after calling.







      1. Safety: signal output and power supply are isolated from RS485 communication electrical signals.


      2. Communication protection: RS485 communication signal output interface adopts overvoltage and overcurrent dual protection.


      3. The output signal type and communication format can be set by software.


      4. Power polarity protection and overcurrent protection.





    III. Technical indicators



































    project




    parameter




    AO



    signal output




    1. Output channel: 8-channel isolation analog output



    2. Output signal type: 0-20mA, 4-20mA, 0-5V, 0-10V, ± 0-10 five analog signals



    3. Sampling rate: 8 channels can be updated once for 5mS



    4. DAC output resolution: 12 bit



    5.accuracy: voltage 0.2% current 0.3%



    6. 20mAcurrent output load resistance: 500 Ou Mu (value)



    Sevenvoltage output load: 10V @ 5mA (value)




    RS485



    communication output




    1. Communication protocol: MODBUS-RTU



    2. Interface type: isolating RS485 communication, the output interface adopts overvoltage and overcurrent dual protection



    3. Baud rate: 1200bps, 2400bps, 4800bps, 9600bps, 19200bps



    4. Check bit: no check, even check, odd check



    5. Setting mode: module address, baud rate and parity can all be set by software



    Sixisolation voltage protection: 1000V




    module size




    A.size of individual module: 104mm * 72mm * 26mm



    b.size of box with terminal and guide rail: 124mm * 72mm * 45mm




    installation method




    standard DIN rail installation (35mm rail or high and low rail)




    working environment




    temperature:-10 ~ + 55℃ humidity: 35 ~ 85% (no condensation)




    working power supply




    1. Electric voltage: 18V ~ 30V wide range of electricity.



    TwoWith power polarity protection and overcurrent protection.



    3. Power consumption: less than 5W




    IV. Product appearance, terminal definition and status indication




    1. Product appearance







    1. terminal definition





































































































































    terminal




    name




    Explain








    terminal




    name




    Explain




    1




    AO5I




    channel 5 current output








    14




    AO0I




    channel 0 current output




    2




    AO5V




    channel 5 voltage output








    15




    AO0V




    channel 0 voltage output




    3




    AOGND




    analog output public ground








    16




    AOGND




    analog output public ground




    4




    AO6I




    channel 6 current output








    17




    AO1I




    channel 1 current output




    5




    AO6V




    channel 6 voltage output








    18




    AO1V




    channel 1 voltage output




    6




    AOGND




    analog output public ground








    19




    AO2I




    channel 2 current output




    7




    AO5I




    channel 7 current output








    20




    AO2V




    channel 2 voltage output




    8




    AO5V




    channel 7 voltage output








    21




    AOGND




    analog output public ground




    9




    AOGND




    analog output public ground








    22




    AO3I




    channel 3 current output




    10




    DATA+




    RS485 Acommunication +








    23




    AO3V




    channel 3 voltage output




    11




    DATA-




    RS485 Bcommunication-








    24




    AO4I




    channel 4 Current output




    12




    +Vs




    power input +








    25




    AO4V




    channel 4 voltage output




    13




    GND




    power input-








    26




    AOGND




    analog output public ground




    4. Module indicator light and switch function description



    1) module indicator light description



    A. POW/SET;module working status refersshown



    B.green light: The module is working in the running state.



    C.Red light: If the configuration parameters of the module have been written, the module will automatically reset.



    2)TXD/RXD:communication status indication



    A.Green light shining: Communication receives data



    B. red light is flashing: The module is sending data



    C.green light Chang Liang: the communication RS485 line connected to DATA + and DATA-is connected reversely or the wiring is disconnected.



    5.Reset switch on the right side of module



    1)when the communication parameters (module address, baud rate, parity) are not known or the communication parameters are incorrectly set, the connection with the module communication cannot be established, the solution is to reset the communication parameters; we press and hold the reset switch with the pin and do not let it go. After 5 seconds, the red indicator light of the module [POW/SET] will be on and the reset switch will be let go. At this time, the communication parameters will be reset automatically.



    2)Communication parameters after reset: Address: 1, baud rate: 9600bps, parity bit: none.



    V. Typical application wiring diagram






    VI. Principle block diagram









    VII. MODBUSregister description



    1. MODBUS function code of the module
































    Code




    Meaning




    operation




    0x03H




    read multiple hold registers




    read the values of one or more hold registers




    0x 06H




    write a single hold register




    write a data into the hold register




    0x 04H




    read multiple input registers




    read the values of one or more input registers




    0x 10H




    write multiple hold registers




    write one or more data into the hold register




    2. Register definition description



    hold register (function code:0x03H、0x06H、0x10H)































































    Modbus



    address




    parameter




    read/Write




    minimum value




    value




    Explain




    40049




    AO0




    read and write




    0




    4095




    analog output channel 0 DA output control value




    40050




    AO1




    read and write




    0




    4095




    analog output channel 1 DA output control value




    40051




    AO2




    read and write




    0




    4095




    analog output channel 2 DA output control value




    40052




    AO3




    read and write




    0




    4095




    analog output channel 3 DA output control value




    40053




    AO4




    read and write




    0




    4095




    analog output Channel 4 DA output control value




    40054




    AO5




    read and write




    0




    4095




    analog output channel 5 DA output control value


    <
    Loading...