Ammonia sensor transmitter detector alarm NH3 VO:0~2.5V, 5V, 10V AO:4~20mA MODBUS RTU RS485
Ammonia sensor transmitter detector alarm NH3 VO:0~2.5V, 5V, 10V AO:4~20mA MODBUS RTU RS485
Ammonia sensor transmitter detector alarm NH3 VO:0~2.5V, 5V, 10V AO:4~20mA MODBUS RTU RS485

Ammonia sensor transmitter detector alarm NH3 VO:0~2.5V, 5V, 10V AO:4~20mA MODBUS RTU RS485

Price:   $181.23

  • Model: ic0A4342
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)
(complete orders today,deliverd around 26/04/2025)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    Inverter 12v 220v Modified Sine Wave Inverter DC 12v To AC 220V 3000W 4000W 6000W Portable Power Bank Converter Solar Inverter
    $271.16
    NI-210 2-channel ASA VI curve tester circuit board online maintenance tool Analog Signature Analysis
    $207.32
    Analog glow tube clock LED creative glow clock DIY parts Full color led imitation glow tube clock as like IN14 clock
    $76.68
    1500W2000W2600W Power Inverter Modified Sine Wave DC 12V To AC 220V Solar 2 USB Car Transformer Convert LCD Display
    $177.44
    • Details
    • Reviews
    • Tags
    • FAQ
    Type:Logic ICs
    Condition:New

    AmmoniaTransmitter

    Product introduction

    This transmitterBuilt in lightning protection, anti reverse, overcurrent and other multiple protection.Complete interchangeability.Be used foraccuratemeasureAmmonia concentration.The transmitter is used as slave station through industrial common interface.RS485 will air pressure.TransformationOutput.Software completeaccording tostandardMODBUS RTUserialcommunication protocolDevelopment.canVery good compatibility.WINCC,Kingview,Force control, Kunlun state, touch screen,PLCAnd other host configuration software.And hardwareAnd the third party according to the standard.The software or hardware developed by MODBUS RTU protocol.andLCD screen can be displayed on-site to display measurement data.,The functions of buzzer sound alarm prompt after exceeding the limit, alarm relay driving alarm equipment action after exceeding the limit, etc.. This paragraphTransmitter power supply and communicationOnly need1 4 core communication cables can transmit sensor data remotely.canIn constructionscenesaveOf large numberCable, the price advantage is very obvious.

    Two.technical parameter

    Detection gas: ammonia (NH3)
    Range: 0~50ppm
    Maximum measurement limit: 200ppm
    Sensitivity: (0.10±0.05) uA/ppm
    Resolution: 0.5ppm
    Response time (T90): ≤90s
    Bias: 0mV
    Load resistance (recommended): 10Ω

    ammonia

    worktemperature:-20~60Centigrade5~95%RH

    storagetemperature:-25~80Centigrade

    Power supply voltage:DC7~24VRecommend:DC12V

    Maximum power consumption:100mA12V, with liquid crystal (0802)

    Display mode:LED indicator orLCD LCD screen

    LCD screen specifications:LCD08028 character *2 line

    Communication interface:RS485

    Communication protocol:MODBUS RTU

    Communication rate: Software settings2400, 4800, 9600, 19200, 38400, 115200etc.. default9600bps

    Data format:default8N1(1 bit start bits, 8 bit data bits, 1 bit stops,nothingCheck)

    Communication mode:TransmitterAs a resultMODBUS RTU slave station, master station (touch screen, PLC, host computer, etc.) uses master-slave polling mode to query the real-time data of the transmitter.

    Node address:1~255Dial switch or soft switchPart setting

    Number of nodes:Theoretically, the same bus is the most.128 transmitters, the actual application of up to 1/2~2/3

    Transmission distance:1000 meters (RS485 communication special cable)

    Before sending out the transmitteralreadyAfter three protection, ensure high temperature and humidity special.soilLong term use.

    Installation: wall mounted

    Product size:115*80*40Mm

    Product specification selection form:

    Serial number

    Name

    Specifications

    Remarks

    1

    Ammonia transmitter

    IS-TM-485-O2-1-DC

    2

    Ammonia transmitter

    IS-TM-485-O2-1-LED-DC

    With LED indicator light

    3

    Ammonia transmitter

    IS-TM-485-O2-1-LCD-DC

    LCD with LCD (0802)

    4

    Ammonia transmitter

    IS-TM-485-O2-1-LED-B1-DC

    With LED indicator, 1 alarm.

    5

    Ammonia transmitter

    IS-TM-485-O2-1-LED-B2-DC

    With LED indicator, 2 alarm.

    6

    Ammonia transmitter

    IS-TM-485-O2-1-LCD-B1-DC

    With LCD indicator, 1 alarm.

    7

    Ammonia transmitter

    IS-TM-485-O2-1-LCD-B2-DC

    With LCD indicator, 2 alarm.

    8

    High range ammonia transmitter

    IS-TM-485-O2-2-DC

    9

    High rangeAmmonia transmitter

    IS-TM-485-O2-2-LED-DC

    With LED indicator light

    10

    High rangeAmmonia transmitter

    IS-TM-485-O2-2-LCD-DC

    LCD with LCD (0802)

    11

    High rangeAmmonia transmitter

    IS-TM-485-O2-2-LED-B1-DC

    With LED indicator, 1 alarm.

    12

    High rangeAmmonia transmitter

    IS-TM-485-O2-2-LED-B2-DC

    With LED indicator, 2 alarm.

    13

    High rangeAmmonia transmitter

    IS-TM-485-O2-2-LCD-B1-DC

    With LCD indicator, 1 alarm.

    14

    High rangeAmmonia transmitter

    IS-TM-485-O2-2-LCD-B2-DC

    With LCD indicator, 2 alarm.

    15

    16

    Customizing

    IS-TM-485-O2-X-C-DC

    Product function customization

    17

    Three.Usage method

    The followingWIN10 64bit system is introduced as an example.

    1.Hardware preparation

    1.1 DC power supply(Not include):

    7~24V, 100mA above



    1.2 RS485 converter(Not include):

    Prepare a good quality.RS485 converter (preferably active RS485 converter), or other hardware with RS485 interface (touch screen, PLC, industrial computer or customer development hardware equipment), USB to RS485 converter or RS232 to RS485 converter can be, must ensure that the converter can send and receive data in two directions, some monitoring converter is single It is impossible to use communication. When buying, you must ask the seller clearly.


    One point threeDownload correspondingRS485If the driver of the converter is installed properly, make sure that the driver is installed correctly and that there is no yellow exclamation mark in front of the installed driver.


    aboutWIN10 64Bit system, installation:


    One point fourLook at the computer.O2MSlogans for earlier desktops or notebooksDB9For public equipment,O2MSlogans are generallyO2M1See through the following ways;

    Right click My computer- - >attribute- - >Device manager- - >Double click port (O2MandLPT)- > USB-SERIAL CH340 (O2M6)

    O2M 6That's what we need later.O2M Slogans;




    2,Hardware connection

    Connect the test cable reserved by the transmitter out of the factory to all the test equipment correctly, and pay attention to the cable core line not to be misconnected.

    red7~24V+

    Blue or blackGND

    yellowRS485 A/ (+)

    green RS485 B/ (-)