Analog input and output analog signal acquisition 0-20mA current 0-10V voltage generator 485
Analog input and output analog signal acquisition 0-20mA current 0-10V voltage generator 485

Analog input and output analog signal acquisition 0-20mA current 0-10V voltage generator 485

Price:   $50.00

  • Model: ic0A284
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)
(complete orders today,deliverd around 25/04/2025)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    RCWL-0515 12-15m long distance 2.7g microwave detection module is suitable for garage lampUV lamp
    $0.63
    DC5V DS18B20 Digital Temperature Sensor Module
    $0.63
    Blue Red Green Yellow Colorful Color HTTM Series Capacitive Touch Switch Button Module
    $0.63
    123467S Single 12.6V Lithium Battery Capacity Indicator Module Blue Display Electric Vehicle Battery Power Tester Li-ion
    $0.80
    • Details
    • Reviews
    • Tags
    • FAQ
    Condition:New
    Type:Logic ICs
    Model:PD3041-4AI4AO
    No.:1
    Color classification:4-20mA input 0-10V output
    Decoration and construction content:Hydropower project

    As long as the output, please note that 4-20mA input 0-10V output, of the 20mA+4 4 into the 10V out of the 30V+4 4 into the 20mA out of the 30V+4 other specifications, please note that 4 into the 20mA out of the 20mA+4 4 into the 10V+4 out of 10V

    This style 4 road analog quantity input +4 analog output module,

    Is derived from the independent function of the module, and related technical parameters of the same, can refer to.

    If you do not need a combination function, you can split the sale.

    For example, users only need4AOThis is the model.PD3041-4AOMask label"4AO"Will be lit by black spots.

    1 PD3041Main characteristics

    quarantineRS485InterfaceModbus-RTU Agreement.

    Power supply: DC8-30V

    Analog sampling precision:16Or18positionAD.

    Analog output accuracy: 4 independent 12 or 14 bit DA.

    Current output type:0-20MA (MAX 21mA), the output voltage is the same as the supply voltage, and the load resistance is not more than910Europe.

    Voltage output type:0-5V,0-10V, the output current is not more than 5MA (finite flow short circuit protection)

    2 product picture


    The interface is as follows:

    A:RS485 Serial communicationA

    B:RS485 Serial communicationB

    Power SupplyV+DC power supply cathode

    Power SupplyGNDDC power supply negative pole, common end

    AIN (x)Analog input terminal

    AOUT (x):Analog output

    3 Register information table and function code

    3.1 Function code03H(read),06H(write)

    Parameter setting register information table 10H-15HPermanent preservation;16H-19HPower down is lost when the power is on.0.

    Word address

    byte

    position

    describe

    Parameter description

    attribute

    10H

    low8position

    Communication configuration

    Initial value:00

    BIT<7> Parameter protection function= 0Close = 1open See note

    BIT<6:5> Retain

    BIT<4:3>00=No verification01=Parity check10=Odd parity check (11=Odd parity check

    BIT<2:0>001=1200 010=2400 011=4800 100=9600 000=9600

    110=19200 101=14400Other combinations are not defined, in accordance with9600Handle

    RW

    high8position

    Postal address

    Initial value:01

    Set value range=1reachTwo hundred and fifty

    address0For a broadcast address (if the communication program is set to the value of the0, equivalent to1)

    RW

    11H

    Retain

    RW

    12H

    low8position

    No.1Road analog output control mode

    Initial value:00

    See note II

    RW

    high8position

    Retain

    RW

    13H

    No.2Road analog output control mode

    RW

    14H

    No.3Road analog output control mode

    RW

    15H

    No.4Road analog output control mode

    RW

    16H

    No.1Road analog output value

    Voltage or current output value,2Byte unsigned integer, numeric unit is:UA,MV.

    When the module is powered on, the value is0. Therefore, the power must be written before the output value will have output.

    RW

    17H

    No.2Road analog output value

    RW

    18H

    No.3Road analog output value

    RW

    19H

    No.4Road analog output value

    RW

    Comment ii:

    0,4-255Mode0, there is no corresponding relationship between analog input and analog output. The analog output value can be set up by the host computer through the communication.

    1Follow mode1,The analog output value of this mode can not be set up by the host computer through the communication. Output value is1:1Follow the input values change.

    Note that if the input and output types are different, for example, the input is0-20mA, the output is0-10V, then enter10mAWill cause the output value to be10V, input and then improve the output will not change.

    2Follow mode2The analog output value of this mode can not be set up by the host computer.

    Set output=y, input=x, this mode is in accordance withY= (8 * x) /5 + 4, conversion.

    The purpose is toX=0reach10convert toY=4reach20.

    3Follow mode3The analog output value of this mode can not be set up by the host computer.

    Set output=y, input=x, this mode is in accordance withY= (5 * x) /8 - 2.5, conversion.

    The purpose is toX=4reach20convert toY=0reach10.

    3.3 Function code10H(write continuous register)

    16H-19HRegister supportMODBUSThe10HCommand. The significance of this function lies in:

    Use06HCommand setting4An output, it should be written separately4Time, and use10HCommand can be written at once4One output.

    3.2 Function code03H(read)

    Data register information table

    This part of the address and data format and the "analog acquisition module" the same, so you can use the "analog acquisition program" test.

    Word address

    describe

    Parameter description

    attribute

    20H

    No.1Analog input value

    Value as32positionFloatType, standardIEEE-754Floating point format.

    Numerical unit for:mA,V.

    R

    22H

    No.2Analog input value

    R

    24H

    No.3Analog input value

    R

    26H

    No.4Analog input value

    R

    28H-3EH

    Retention, read value as0

    R

    40H

    No.1Digital output code

    Value as32Bit unsigned long integer(signed int long).

    R

    42H

    No.2Digital output code

    R

    44H

    No.3Digital output code

    R

    46H

    No.4Digital output code

    R

    48H-5EH

    Retention, read value as0

    R

    60H

    No.1Analog input value

    Value for symbolic integer,-32768 - 32767Unit for:UA,MV. For example:25432Express25432 (uA,MV)Amount to25.432 (mA,V)

    R