Analog input and output modules 0-20mA analog capture current and voltage generator 485
Analog input and output modules 0-20mA analog capture current and voltage generator 485

Analog input and output modules 0-20mA analog capture current and voltage generator 485

Price:   $50.00

  • Model: ic0A4656
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)
(complete orders today,deliverd around 24/04/2025)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    2pcslot TEC1-12705 Thermoelectric Cooler Peltier 12705 12V 5A Peltier Cells
    $8.98
    Temperature and humidity sensors, air temperature and humidity, protective cover, SHT10 sht20, high humidity of flue cured tobac
    $18.65
    AD828 Dynamic Microphone Stereo Front Amplifier Board Audio Amplifier Module DIY Audio Modification Accessories
    $1.12
    HY-SRF05 SRF05 Ultrasonic Distance Sensor Module 5Pin DC 5V for Arduino Replace SR04 Electronic Brick Compatible Interface
    $1.12
    • Details
    • Reviews
    • Tags
    • FAQ
    Type:Logic ICs
    Condition:New
    Model:PD3041-4AI4AO
    Item:1
    Color Classification:4 into 20mA + 4 out and the 10V or 20mA 4 20mA 4 into the 30V + 4 out
    Renovation and construction content:Hydropower Engineering

    4 communications test program interface :


    4 into 30Vand 4 out and the 10V

    4 into 20mAand 4 into the 10V

    4into30Vand4out 20mA

    4 out 10Vor 20mA

    4 in 20mA and 4 out 20mA

    please not what you choose above.

    This style 4 analog inputs +4 analog output combination module ,

    Is derived from independent functional modules to the same technical data , reference can be.

    Combination of features if you do not , you can split the sale .

    For example, the user only needs4AOThis is such a modelPD3041-4AO, Mask label "4AO" It will be the point on the black spot .

    1 PD3041Main features

    IsolationRS485Interface ,Modbus-RTU Agreement.

    Power supply: DC8-30VRecommended12VPowered by.

    Analog sampling accuracy :16Bit or18PositionAD.

    Current output type:0-20mA (21mA MAX)The output voltage is the same as the supply voltage , load resistance does not exceed910Europe .

    Voltage output type :0-5V,0-10VThe output current is less than3mA

    2 Product Image


    Interface as follows :

    A:RS485 Serial CommunicationsA

    B:RS485 Serial CommunicationsB

    Power supplyV +: DC power positive

    Power supplyGND: DC power supply negative common

    AIN (x): Analog inputs

    AOUT (x):Analog output terminal

    3 Register information table and function code

    3.1 Function code03H( Read)06H( Write )

    Parameter setting register information table 10H-15HPermanent preservation ;16H-19HBrownout is lost when the power is0.

    Word Address

    Byte

    Location

    Description

    Parameter Description

    Property

    10H

    Low8Position

    Communication Configuration

    Initial value:00

    BIT<7> Parameter protection0 =Shut down 1 =Open See Note

    BIT<6:5> Retention

    BIT<4:3>00 =No parity01 =Even parity10 =Odd parity (11 =Odd parity )

    BIT<2:0>000 = 9,600,001 = 1,200,010 = 2,400,011 = 4,800,100 = 9600

    101 = 14400110 = 19200Other combinations are not defined , in accordance with9600Deal with

    RW

    High8Position

    Mailing Address

    Initial value:01

    Setpoint range= 1To250

    Address0Broadcast address ( If the value set for the communication program0Equivalent to1)

    RW

    11H

    Retention

    RW

    12H

    Low8Position

    Article1Analog output control mode

    Initial value:00

    See note

    RW

    High8Position

    Retention

    RW

    13H

    Article2Analog output control mode

    RW

    14H

    Article3Analog output control mode

    RW

    15H

    Article4Analog output control mode

    RW

    16H

    Article1Analog output value

    Voltage or current output value ,2Unsigned integer value in bytes is:uA,mV.

    When the module is powered up, the value is0. Therefore, the value must be written after power output will have .

    RW

    17H

    Article2Analog output value

    RW

    18H

    Article3Analog output value

    RW

    19H

    Article4Analog output value

    RW

    Notes :

    0,4-255: Mode0Analog input and analog output no correspondence , belonging to an independent state. Analog output value can be set via the PC communication .

    1: Follow-up mode1 ,This mode analog output value can not be set by the host computer via the communication . Output value of1 : 1Follows the input value changes .

    Note that if the input and output types, such as input is0-20mA, The output is0-10VThen enter10mAWill cause the output value is10V, The input will not further increase the output variation .

    2: Follow-up mode2This mode analog output value can not be set by the host computer via the communication .

    Set output= yEnter the= x, According to this modey = (8 * x) / 5 + 4Conversion .

    Purpose is tox = 0To10Converty = 4To20.

    3: Follow-up mode3This mode analog output value can not be set by the host computer via the communication .

    Set output= yEnter the= x, According to this modey = (5 * x) / 8 - 2.5Conversion .

    Purpose is tox = 4To20Converty = 0To10.

    The user is not specified, the function does not provide a model 2,3 ,

    3.2 Function code03H( Reading )

    Data register information table

    This part of the address and data formats and " analog acquisition module ," the same , so you can use the " analog acquisition program " test .

    Word Address

    Description

    Parameter Description

    Property

    20H

    Article1Channel analog input values