Type:Logic ICs
Condition:New
Model:PD3041-4AI4AO
Item:1
Color Classification:4 into 20mA + 4 out and the 10V or 20mA 4 20mA 4 into the 30V + 4 out
Renovation and construction content:Hydropower Engineering
4 communications test program interface :

4 into 30Vand 4 out and the 10V
4 into 20mAand 4 into the 10V
4into30Vand4out 20mA
4 out 10Vor 20mA
4 in 20mA and 4 out 20mA
please not what you choose above.
This style 4 analog inputs +4 analog output combination module ,
Is derived from independent functional modules to the same technical data , reference can be.
Combination of features if you do not , you can split the sale .
For example, the user only needs4AOThis is such a modelPD3041-4AO, Mask label "4AO" It will be the point on the black spot .
1 PD3041Main features
IsolationRS485Interface ,Modbus-RTU Agreement.
Power supply: DC8-30VRecommended12VPowered by.
Analog sampling accuracy :16Bit or18PositionAD.
Current output type:0-20mA (21mA MAX)The output voltage is the same as the supply voltage , load resistance does not exceed910Europe .
Voltage output type :0-5V,0-10VThe output current is less than3mA
2 Product Image

Interface as follows :
A:RS485 Serial CommunicationsA
B:RS485 Serial CommunicationsB
Power supplyV +: DC power positive
Power supplyGND: DC power supply negative common
AIN (x): Analog inputs
AOUT (x):Analog output terminal
3 Register information table and function code
3.1 Function code03H( Read)06H( Write )
Parameter setting register information table 10H-15HPermanent preservation ;16H-19HBrownout is lost when the power is0.
Word Address | Byte Location | Description | Parameter Description | Property |
10H | Low8Position | Communication Configuration Initial value:00 | BIT<7> Parameter protection0 =Shut down 1 =Open See Note BIT<6:5> Retention BIT<4:3>00 =No parity01 =Even parity10 =Odd parity (11 =Odd parity ) BIT<2:0>000 = 9,600,001 = 1,200,010 = 2,400,011 = 4,800,100 = 9600 101 = 14400110 = 19200Other combinations are not defined , in accordance with9600Deal with | RW |
High8Position | Mailing Address Initial value:01 | Setpoint range= 1To250 Address0Broadcast address ( If the value set for the communication program0Equivalent to1) | RW |
11H | | Retention | | RW |
12H | Low8Position | Article1Analog output control mode Initial value:00 | See note | RW |
High8Position | Retention | RW |
13H | | Article2Analog output control mode | RW |
14H | | Article3Analog output control mode | RW |
15H | | Article4Analog output control mode | RW |
16H | | Article1Analog output value | Voltage or current output value ,2Unsigned integer value in bytes is:uA,mV. When the module is powered up, the value is0. Therefore, the value must be written after power output will have . | RW |
17H | | Article2Analog output value | RW |
18H | | Article3Analog output value | RW |
19H | | Article4Analog output value | RW |
Notes :
0,4-255: Mode0Analog input and analog output no correspondence , belonging to an independent state. Analog output value can be set via the PC communication .
1: Follow-up mode1 ,This mode analog output value can not be set by the host computer via the communication . Output value of1 : 1Follows the input value changes .
Note that if the input and output types, such as input is0-20mA, The output is0-10VThen enter10mAWill cause the output value is10V, The input will not further increase the output variation .
2: Follow-up mode2This mode analog output value can not be set by the host computer via the communication .
Set output= yEnter the= x, According to this modey = (8 * x) / 5 + 4Conversion .
Purpose is tox = 0To10Converty = 4To20.
3: Follow-up mode3This mode analog output value can not be set by the host computer via the communication .
Set output= yEnter the= x, According to this modey = (5 * x) / 8 - 2.5Conversion .
Purpose is tox = 4To20Converty = 0To10.
The user is not specified, the function does not provide a model 2,3 ,
3.2 Function code03H( Reading )
Data register information table
This part of the address and data formats and " analog acquisition module ," the same , so you can use the " analog acquisition program " test .
Word Address | Description | Parameter Description | Property |
20H | Article1Channel analog input values | |