Dissipation Power:W
Operating Temperature:C
Supply Voltage:V
Type:Logic ICs
Condition:New
Application:0
First, an overview:
DJL-C352High and low liquid level controllerNon contact type liquid level sensor can be used in conjunction with DJL-Y25, can also be combined with other floating ball liquid level sensor used to achieve the liquid level of a container is too little by the liquid level sensor low liquid level alarm signal emitted when the pump starts automatically with the liquid level, the liquid level reaches a certain height high level sensor sends a signal to the pump automatically stops working, so as to realize the automatic level of container control function. The controller self protection ability with the pump to stop pumping air detection, high overflow detection, flush timeout detection; manual mode control can control various pumps, can also control the water pump automatic mode; multiple output mode, a load output control power up to 1600W, all the way alarm output control up to800W, there are normally open relay output, but also to exchange110Vor220VOutput. The controller function set is complete, suitable for a wide range of applications.
Two, characteristics:
1The compatibility and the use of a variety of liquid level sensor input control;
TwoAnd protection ability, with waterproof protection and water pump idle overflow detection with output.4Hours overtime pumping alarm;
ThreeRelay output, can be applied to a variety of load control;
FourControl of diversification, can be manual or automatic mode control pump;
FiveThe installation is simple and convenient, and can be positioned and installed with screws, and can also be installed in the electric box;
Three, electrical parameters:
Model | DJL-C352 | Name | C352Automatic controller for high and low liquid level |
input voltage | AC100V-220V,50/60Hz |
working voltage | DC12V |
Operating current | The working current is less than or equal to110 mAStatic current consumption is less than or equal.20mA |
Load power | 1.6KWThe following (overload or for three-phase water pump need to install AC contactor) |
Alarm output | 800W (resistive load) normally open normally closed output |
Output mode | Relay normally open normally closed or ACAC110V/220Vtwo types2Select one output |
Input signal | Low signal input; High input; The pump idling detection signal input; Overflow alarm signal input; |
Induced head interface voltage | DC 12V |
working temperature | -10~75C |
Outline dimension | 115*90*40 |
Signal input and relay output:
Input signal | Load output | | Alarm signal state | Alarm output |
Down to 0, high as0 | Normally open and close, normally closed. | Robin ring | Down to 0, high as1 | Normally open and close, normally closed. |
Down to 1, high as0 | Normally open and close, normally closed. | High overflow to 1 | Normally open and close, normally closed. |
Down to 1, high as1 | Normally open, normally closed | Alarm state, load output: normally open, normally closed (relay off state, load off to protect) |
Down to 1, high as0 | Normally open, normally closed |
Water detection is 0When, | Normally open, normally closed (relay off state, load off to protect) |
Four, basic functions:
1.Automatic control of water level:The water level is lower than the low position induction probe, the automatic start water pump, the water level rises to the high position, the automatic closing the water pump.
2.Stop the pump idle time delay:After startup, such as the detection of water supply pipe, the delay3~5Minutes to close the pump. In the process of pumping water, such as the flow of water3Seconds or more, then immediately shut off the pump.
ThreeAutomatic tracking of water source:Idling after the pump stops every two hours to start a water pump, water pump until the full stop.
FourPump timeout protection:Continuous automatic pumping more than5Automatic stop pump. Work indicator light flashes quickly, can pressK2Key to stop, or automatic delay recovery.
FiveManual automatic switching:The controller is started by default into the automatic mode of operation.K1Key to switch the working mode, the red light is automatic mode, the red light is used as the manual mode.
6.Non contact inductive probe: Non contact capacitive sensing technology and dedicated induction control chip design, the probe has a durable, strong anti-interference ability, sensitive, not in contact with liquid, corrosion resistance, safety and environmental protection without pollution.