Atmospheric pressure, temperature and humidity, 3 in 1 high-precision transmitter, air pressure detector RS485 MODBUS-RTU
Atmospheric pressure, temperature and humidity, 3 in 1 high-precision transmitter, air pressure detector RS485 MODBUS-RTU
Atmospheric pressure, temperature and humidity, 3 in 1 high-precision transmitter, air pressure detector RS485 MODBUS-RTU

Atmospheric pressure, temperature and humidity, 3 in 1 high-precision transmitter, air pressure detector RS485 MODBUS-RTU

Price:   $93.28

  • Model: ic0A722
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)

Please Choose:

Option
(complete orders today,deliverd around 25/04/2025)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    50pcslot IRG4PC30U G4PC30U IGBT TO-247
    $45.00
    Automotive water fuel HHO high current, constant current controller to enhance power, fuel-saving components are required
    $94.98
    1-5pcs 100% New ISL9238CHRTZ ISL9238CH 9238CH QFN
    $51.90
    TPA3118D2 Digital Audio Amplifier Board Dual Channel 45Wx2 Stereo HIFI Speaker Volume Control Sound Board High Power Subwoofer
    $4.32
    • Details
    • Reviews
    • Tags
    • FAQ
    Condition:New
    Type:Logic ICs


    Atmospheric pressure temperature and humidity 3 in 1 high precision transmitter Air pressure detector RS485 MODBUS-RTU



    A:Simple type(Without indicator and LCD screen)



    B:Simple type + indicator light



    C:Simple type + LCD screen



    D:Simple type + indicator light + 1-channel alarm



    E:Simple type + LCD screen + 1-channel alarm



    TB286fsqd0opuFjSZFxXXaDNVXa_!!383990198



    First, product introduction



    The transmitter core module air pressure sensor is a high-precision, small-volume, ultra-low-power pressure sensor that can be used in mobile devices. It has excellent performance, absolute accuracy of 0.03hPa, and low power consumption. Only 3μA, it is powered by a powerful 8-pin ceramic leadless chip carrier (LCC) ultra-thin package that can be directly connected to various microprocessors via the I2C bus.


    Main features of the air pressure module:

    Pressure range: 300~1100hPa (90m~-500m above sea level)





    Low power consumption: 5μA in standard mode





    High precision: in low power mode, the resolution is 0.06hPa (0.5m)





    In high linear mode, the resolution is 0.03hPa (0.25m)





    Temperature output





    Temperature compensation





    Lead-free, RoHS compliant





    MSL 1 reaction time: 7.5ms





    Standby current: 0.1μA





    No external clock circuit required





    The air pressure transmitter has built-in multiple protections such as lightning protection, anti-reverse connection and over-current. The product is fully interchangeable and is used to accurately measure soil temperature and humidity. The transmitter acts as a slave to transmit the air pressure through the industrial universal interface RS485. The software was developed in full compliance with the standard MODBUS RTU serial communication protocol. It can be well compatible with WINCC, Kingview, Force Control, Kunlun Tongzhou, touch screen, PLC and other PC configuration software and hardware, as well as software or hardware developed by third parties according to the standard MODBUS RTU protocol. And optional LCD screen display measurement data, after the limit of the buzzer sound alarm prompt, after the limit of the alarm relay drive alarm device action and other functions. This transmitter can supply and communicate with only one 4-core communication cable to transmit sensor data remotely. It can save a lot of cables on the construction site, and the price advantage is very obvious.



    Applications:

    Can be widely used in:





    GPS precision navigation (dead reckoning, upper and lower bridge detection, etc.), indoor and outdoor navigation, leisure, sports and medical health monitoring, weather forecasting, vertical speed indication (rising/sinking speed), fan power control, weather station air pressure monitor , detectors, automatic control systems, environmental pressure monitoring systems, aircraft altimetry systems, industrial, plant and other places that need to be measured.




    Second, technical parameters


    Supply voltage: DC 7~24V, recommended: DC12V

    Maximum power consumption: 100mA@12V with LCD (0802)

    Display mode: LED indicator or LCD screen

    LCD screen specifications: LCD0802 8 characters * 2 lines

    Communication interface: RS485

    Communication protocol: MODBUS RTU

    Communication rate: Software settings, 2400, 4800, 9600, 19200, 38400, 115200, etc. Default 9600bps

    Data format: default 8N1 (1 bit start bit, 8 data bits, 1 stop bit, no parity)

    Communication mode: The transmitter acts as a MODBUS RTU slave station, and the master station (touch screen, PLC, host computer, etc.) uses the master-slave polling method to query the real-time data of the transmitter.

    Node address: 1~255, DIP switch or software setting

    Number of nodes: theoretically up to 128 transmitters on the same bus, the actual application takes up 1/2~2/3

    Transmission distance: 1000 meters (RS485 communication dedicated cable)

    The transmitter has been treated three times before leaving the factory to ensure long-term use under high temperature and high humidity special soil.

    Installation method: wall-mounted

    Product size: 115*80*40 mm







    Third, the method of use






    Hardware parts:





    First plug the network cable into the waterproof Ethernet interface of the product, and connect the other end to the computer or router, hub, switch, etc., then connect your own switching power supply or the power adapter of the product to the power cable, or directly connect the power adapter to the DC. Plug the plug into the reserved power hole of the product.





    Software parts:


    According to your own system, choose to install 32-bit or 64-bit software. Generally, you only need to install modbus poll software. The following takes the WIN10 64-bit system as an example.

    Click: I accept the terms of the license Agreement ---> Next ---> Next ---> Install ---> Next ---> Cancel the check box before Show Readme - ---> Finish

    After the above steps, the software installation is complete.
    11
    12
    13
    14
    15


    Power on the device. After a few seconds of product initialization, open the test file provided by the company, you can see the data collected by the transmitter, as shown below.
    20190819123230


    Modify the alarm value upper limit, lower limit, transmitter address, baud rate, check digit and other parameter methods to modify the transmitter address as an example





    1 Mouse directly double-click the desired transmitter address value, ie 1, the following interface pops up:


    16





    2 Modify the value behind 1 to the actual required value, the range 1~253, 254 is the universal query address, address 254, only suitable for the case where the bus has only one device. Here we set the value of 1 to 3, and then click the Send button, the address of the current device, you can change to 3, the device does not need to power off, the new value automatically takes effect.


    16





    In order to better understand and learn the MODBUS RTU/TCP protocol, click on the menu bar Display--->Communication, you will see the instructions from the computer to get the data and the data returned by the transmitter; TX is the command issued by the computer. RX is the data returned by the transmitter


    18






    Six, matters needing attention






    1. The transmitter is equipped with no test power supply and RS485 converter. If necessary, please contact the customer to purchase or purchase it yourself!





    2. The power supply voltage and output current used must meet the requirements, otherwise the product may be damaged or may not work properly.





    3. When connecting the transmitter cable, be careful not to connect it incorrectly, otherwise it may burn internal components or not work properly.





    4. Please use RS485 special cable as much as possible to improve transmission distance and stability.





    5. The transmitter station address setting must not be duplicated with other slave addresses.





    6. The transmitter has built-in 120Ω termination resistor. When the transmitter is at the end of the 485 bus, please close the S3 shorting sleeve.





    7, the transmitter slave station no more than 31, otherwise need to add RS485 bus bridge (relay), and the main station MODBUS RTU / TCP protocol, baud rate and other data formats must be consistent.





    8. The default communication baud rate is 9600bps and 8N1 data format when the product leaves the factory. If the user needs to modify the baud rate or data format, we provide the program software to modify it.