Battery inspector 32 way 0-30V 60V 160V 260V 500V analog data acquisition module RS485 MODBUS RTU

Battery inspector 32 way 0-30V 60V 160V 260V 500V analog data acquisition module RS485 MODBUS RTU

Price:   $64.98

  • Model: ic0A1272
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)
(complete orders today,deliverd around 26/04/2025)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    DT01 Rail Type Digital Thermostat High-precision Digital Display Temperature Controller Module NTC 10K Probe Cable 18B20 Sensor
    $13.40
    9-in-1 All-metal Extruder Set for 3D printer MK-8 Extruder Feeder 1m Tube Low Friction Pipe Cutter 3D Printer Accessories
    $13.42
    Creative dual 7-segment symmetrical spectrum light professional audio analyzer music level indicator LED acrylic jump light VU
    $142.35
    Micro Temperature Controller ZFX-W3003 Thermostat Thermoregulator Heating and Cooling Intelligent Incubator Water Temp Regulator
    $14.08
    • Details
    • Reviews
    • Tags
    • FAQ
    Type:Logic ICs
    Condition:New
    Model:PD3058-PLC32V
    Decoration and construction contents:Installation engineering

    OneSummary

    This style of 32 way analog input module.It is derived from the 12 module, which is actually the increase in the number of channels.

    The relevant technical parameters are the same. Standard SixteenbitADchip.

    The sampling GND is completely isolated from the three terminals of power supply and communication.

    Common specifications are as follows:The divider resistor has been integrated inside the module.

    Range specification

    application area

    Divider resistance ratio ADFullness

    Actual measurement range

    5V

    5VInternal voltage measurement

    82K:3.24K 256MV

    -3VLeft and right+5.8V

    10V

    10VInternal voltage measurement

    150K:3.24K 256mV

    -7VLeft and right+12V

    30V

    30VInternal voltage measurement

    390K:3.24K 256mV

    -20VLeft and right+31V

    60V

    60VInternal voltage measurement

    787K:3.24K 256mV

    -40VLeft and right+62V

    160V

    120VInternal voltage measurement

    2.2M:3.24K 256mV

    -110V reach +173

    260V

    12VBattery18Series voltage216VThe highest260V

    3.3M:3.24K 256mV

    -120V reach +260V

    500V

    12VBattery24Series voltage288VThe highest350V

    3.3M:3.24K 512mV

    -240V reach +521V

    ThreeModule interface

    Power Supply(+,-)Power supply8V-30VThe positive and negative poles. The power supply has reverse connection protection.

    The two(+)It's linked together, two.(-)They are linked together.

    (A,B)meet485AA,B.

    GNDVoltage: common terminal, internally connected with (power supply)-)

    IN1-IN32Voltage input

    The indicator lights are always bright and will flash when communicating.

    5 Module application technology

    5.1 MODBUSagreed interpretation

    Please refer to "V2.4Single-phase three phaseLEDLCDThe general instruction of instrumentMODBUSThe introduction.

    We can use the test tools provided by us to view the collected data. The following figure.

    Test access-12Vand+12V.


    A higher resolution can be obtained by selecting the appropriate decimal number according to different ranges.. The following chart is for fuel cells.32road2VModule of range.

    The test voltage of the user is-0.5V-+2Between V, precision error is required.2mVWithin.

    So choose4The decimal number is very accurate and the error can be controlled.0.2mVWithin.


    Voltage detection scheme for series battery

    Because there is such a problem in series sampling, for example,IN1=1.000VIN2=2.123VIN3=2.987VIn fact,

    Battery voltage is: battery.1=1.000VBattery2=2.123-1.000=1.123VBattery3=2.987-2.123=0.865V.

    Users can subtract the collected data themselves to get effective data, which is a bit troublesome, so we provide a set of difference registers.

    Specially complete this subtraction operation.


    For example, a series battery is the following channel register.60HStart data selection3A decimal number.


    To get the voltage of each battery, read the difference register.80HStart data selection3A decimal number.

    Modscan32test Symbolic integer register


    Modbuss pooltest Symbolic integer register


    Word address

    describe

    Word address

    describe

    80H

    The first1Road input value

    90H

    (17road-The first16Input value)

    81H

    (2road-The first1Input value)

    91H

    Principle same

    82H

    (3road-The first2Input value)

    92H

    Principle same

    83H

    Principle same

    93H

    Principle same

    84H

    Principle same

    94H

    Principle same

    85H

    Principle same

    95H

    Principle same

    86H

    Principle same

    96H

    Principle same

    87H

    Principle same

    97H

    Principle same

    88H

    Principle same

    98H

    Principle same

    89H

    Principle same

    99H

    Principle same

    8AH

    Principle same

    9AH

    Principle same

    8BH

    Principle same

    9BH

    Principle same

    8CH

    Principle same

    9CH

    Principle same