Contactless three phase solid state relay TSR-25AA-S
Contactless three phase solid state relay TSR-25AA-S
Contactless three phase solid state relay TSR-25AA-S

Contactless three phase solid state relay TSR-25AA-S

Price:   $30.84

  • Model: ic0A394
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)
(complete orders today,deliverd around 25/04/2025)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    85pcs 10Types Integrated Circuit chip Assortment Kit,opamp,Single Precision Timer,pwm,Including:LM324 LM358 LM386 LM393 UA741..
    $6.99
    IC MIX3901 TSSOP24 DC2021+ Interface - serializer, solution series New original Not only sales and recycling chip 1PCS
    $1.00
    Original genuine patch ESP32-D0WDQ6 QFN48 WiFi&ampBluetooth two-in-one wireless transceiver chip
    $1.27
    Original genuine ESP32-PICO-D4 QFN-48 dual-core Wi-Fi&ampBluetooth MCU wireless transceiver chip
    $2.15
    • Details
    • Reviews
    • Tags
    • FAQ
    Type:Logic ICs
    Condition:New
    Model Number:TSR-25AA-S
    Application scope:solid state
    Contact load:25A
    Contact switching current:25
    Contact switching voltage:380
    contact form:Noncontact, normally open
    Rated current:25
    Rated voltage:380V
    Coil power supply:3-32VDC
    Coil power:10-20ma
    Rated voltage range of 3C:Below 36V

    Three phase solid state relay, three phase contactless relay, self contained buckle, self provided radiator, small size, replaceable contactor.

    TSR-25AA-S2


    This product
    Characteristic

    The photoelectric isolation between the control loop and the load loop.
    Silicon controlled output, zero current turn off.
    The voltage is over zero. Small size, with its own rail,
    Control signal is compatible with TTL logic; optional safety shield.
    Long square shape, epoxy resin encapsulation (module).
    The three phase start-up characteristics are consistent.
    Flame retardant engineering plastic shell, metal plate
    Wide range of applications: such as industrial electric stove, oven, water pump, motor, electrical switchgear, automatic control and so on.

    The following is the three phase contactless relay parameters:
    Model

    TSR-5AA-S TSR-10AA-S TSR-15AA-S TSR-25AA-S

    TSR-32AA-S TSR-40AA-S

    transport
    enter
    ginseng
    number
    control mode90-250VAC (Communication)
    Input current10-20MA
    Work instructionsLED
    Break timeLess than 10mS (millisecond)
    Reliable off voltageless than0.8VDC
    transport
    Out of
    ginseng
    number
    Output withstand voltageAC 380VAC
    Rated working current5A.10A.15A.25A.32A.40A
    VpkLess than 1.5V
    Minimum conduction current50MA
    Broken leakage currentLess than 10mA
    nature
    can
    ginseng
    number
    Dielectric Strength2500VAC1 minutes
    Insulation voltageMore than 2500V
    insulation resistanceMore than 100M Omega
    working temperature- 35~75 degrees centigrade
    Power frequency50/60HZ
    Heat dissipation condition/
    Safety factor of load currentThe resistive load is 2-4 times, and the inductive load is 3-5 times
    Shape size73.0L x 45.0W x 76.0H
    weight260g

    Items of attention to the selection of products:
    When choosing a product, there should be different allowance on the current grade depending on the nature of the load. The resistive load can be selected by 2-3 times load current. When the load is inductive or capacitive, it can be selected by 3-5 times load current.
    According to the relationship between load current and ambient temperature, when the ambient temperature is higher or the heat dissipation condition is not good enough. The current capacity should be increased. In order to prevent short-circuit of load in use, it is required to connect a fast breaker switch or a fast fuse in series with the corresponding product in the load circuit.
    When inductive load is applied, it should be connected to the output terminal and varistors to prevent damage to thyristors when overvoltage is applied. The selection of varistors (MOV): when 240V is selected, 430-470V is selected, when 440V is selected, 680-750V is selected, and 1100-1200V is selected when 660V files are selected.
    When installing, the radiator and the contact surface of the product must be smooth and clean, and a layer of heat conductive silicone grease is evenly coated on the surface of the radiator. Finally, the screw of the flat washer and spring washer is tightened and fixed.
    When the solid state relay works for the first time, the fixed screw should be tightened before its remaining temperature, so that the surface of the solid state relay floor and the radiator surface can be contacted closely to achieve the best heat dissipation effect.
    * the nominal current of different types of solid state relay is the nominal current at ambient temperature of 40 degrees, so the heat dissipation should be sufficient!!