Condition:New
Type:Logic ICs
No.:JY-1412
Color classification:Control board + sensor control panel + sensor + matching power supply
working principle:Electronic temperature and humidity controller
power:250V10A
Temperature range of temperature control:100 C
baby patch welding, manual welding, welding weld to solve the lack of problems, more reliable product performance.Our latest design, digital display intelligent temperature and humidity controller / monitor, the whole network
The strongest performance, convenient operation, plastic greenhouse, greenhouse, incubator, Poultry house environmental temperature and humidity control choice. Note: there are two kinds of red and green color plate, do not accept the choice, random delivery.
***************************************************************** detailed list 1, a capacitive temperature and humidity sensor (plug has been produced, can be directly Plug in the control panel 2, intelligent temperature and humidity control board
***************************************************************** Functional properties
1 temperature measurement range -40--80 degrees C 2 humidity measurement range 0%RH--99.9%RH 3 temperature resolution of Zero point one degrees C, humidity resolution Zero point one%RH (control accuracy0.1)4.Memory protection function with power off parameters5 power input reverse connection protection, the controller does not work against, don't worry about the effect of burning equipment.6 temperature and Humidity Cycle display (with indicator light)7 dual path control relay, 10A/250V high power output (with instructions).8 can be combined in a total of 4 working modes: desiccant, heating; humidification, heating; desiccant, cooling; humidification, cooling. Really meet your control needs in a variety of situations.9. 5-24V wide supply voltage input: both USB 5V or industrial control of 24V, the controller with ease, really do the most widely applicable, no longer have to worry about power supply. Bright blue LED power indication, beautiful eye-catching.10 highlight 4 red digital display, clear and eye-catching, with degrees Celsius C symbol and humidity H symbol.10. The settings menu to maximize simplified, and retain the function of all, red, yellow, and green with 3 LED, human operation convenient, no longer have to remember the cumbersome code.11 each relay comes with a purple LED instructions, open and disconnect at a glance, easy to control the device operating state. 12 volume: 9.4CM*6.2CM*2CM First, product features1, has four kinds of working mode,
Desiccant, heat, humidity, heat, humidity, cooling; humidification, cooling2, can be detected at the same time temperature and humidity and display3, on the power automatically read set temperature, humidity, working mode and temperature and humidity difference4, two way 10A 250V quality relay control (can be used to control the external load, such as: heating, cooling)5, power off automatic storage settings parameters (MCU built-in EEPROM storage unit)6, humidityBack to the difference between the 0 settings, step 0.1% (0.0-50.0)7, the temperature back to the difference between the 0 settings, step into 0.1 degrees Celsius (0.0-50.0)8, the input voltage range of DC5-24V can be
Standard version of the temperature and humidity controller1.0SParameter table |
Channel number | Dual channel (sensor type AM2301) |
pattern | dehumidification/Refrigeration,dehumidification/heating,Once wet/refrigeration,Once wet/heating |
Humidity measurement range | 0 - 99.9%RH |
Temperature measurement range | -40 - 80 |
Temperature resolution | 0.1C |
Humidity resolution | 0.1%RH |
Output drive capability | 10A, 250VDouble way |
supply voltage | DC 0.5A 5-24V |
Display mode | Digital tubeZero point three sixInch,4position |
Auxiliary display module | Red yellow and greenLED, auxiliary indicator setting parameters |
Input mode | The touch of a button |
Auxiliary function | Each relay with purpleLEDIndication closure. State switch alarm |
Specification size | 94*62*20mm,80G. Locating hole88*56mm,M3mm |
Temperature and humidity controller wiring instructions:Power supply side: + is the positive, - is the negative, you can directly use DC power supply line. Connect the power line through the tube, flat right end can be used to dial. Need to support the DC power line of the motor below Output terminal:Two way relay output, the output interface is a graph label: the middle is the common end, the graph connection is normally closed, the other end is often open.
Reality show Back view: Power input terminal Set button and indicator light Output relay and instruction Relay output tin, a large current can be applied so as not to burn off the copper skin. More reliable performance
Boot process Connected to the power supply and equipment, you can power supply (5-24V)The parameters of the controller are automatically read by the controller.Then display the default humidity A value, red CH-A flashes 3 times (LED1).Then shows the default temperature B value, blue CH-B flashes 3 times (LED2).Finally shows the working mode, yellow MODE flashes 3 times (LED3).Temperature and humidity measurementTemperature and humidity turns display, 1: temperature display LED1, XX.XC bright, other out; 2: humidity display LED2, XX.XH bright, other out
Parameter setting methodPress SET key, red CH-A began flashing, the display is set to set humidity A, according to T-- T++ to set the required humidity A. Display template xx.xH Press the SET key again,Red CH-AStart flashing, the display is set to the humidity A back difference, according to T-- A to set the humidity T++ back difference. Display template x.x HThe temperature is set to complete, wait for 3S or press SET key to enter the humidity setting. Press SET key,Green CH-BStart flashing, the display screen to display the set temperature B, according to T-- T++ to set the required temperature B. Display template xx.xC Press the SET key again,Green CH-BStart flashing, the display set temperature B back to the difference, according to T-- T++ to set the temperature B back to the difference. Display template x.x L Humidity setting is complete, wait for 3S or press SET key to enter working mode to set.Press SET key,Yellow MODE start flashing, display work mode, according to T-- T++ to set the working mode Mode 1: heating / humidificationMode 2: heating / desiccantMode 3: refrigeration / humidificationMode 4: refrigeration / desiccant
Shown as X PP. All parameters can be automatically saved. Press the SET key to exit setup again,LED full out, showing the actual measurement of temperature and humidity, the system automatically save the settings of the parameters, began to enter the work of the corresponding mode of work. Special note:In the SET, T++, T-- key settings, 4S without any key action, the system automatically save the current settings of the parameters, and then show the measurement temperature and enter the corresponding work mode. Press the button, the key is automatically increased.
Five, working modeMode 1: heat / humidityWhen the temperature is lower than the set temperature A, the relay A closed with the lights A light. When the temperature > Settings temperature A temperature A+ return difference, the relay A off, the indicator light A out. When the humidity is lower than the set humidity B, the relay B closed with the lights B light. When the humidity > set humidity B+ humidity B return difference, the relay B off, the indicator light B out. Mode 2: heat / desiccantWhen the temperature is lower than the set temperature A, the relay A closed with the lights A light. When the temperature > Settings temperature A temperature A+ return difference, the relay A off, the indicator light A out. When the humidity is higher than the set humidity B, the relay B closed with the lights B light. When the humidity < sets humidity B - humidity B return difference, the relay B off, the indicator light B out. Mode 3: refrigeration / humidificationWhen the DS1 temperature is higher than the set temperature A, the relay A closed with the lights A lights. When the DS1 temperature < sets temperature A temperature A- return difference, the relay A off, indicating lamp A out. When the humidity is lower than the set humidity B, the relay B closed with the lights B light. When the humidity > set humidity B+ humidity B return difference, the relay B off, the indicator light B out. Mode 4: refrigeration / desiccantWhen the DS1 temperature is higher than the set temperature A, the relay A closed with the lights A lights. When the DS1 temperature < sets temperature A temperature A- return difference, the relay A off, indicating lamp A out. When the humidity is higher than the set humidity B, the relay B closed with the lights B light. When the humidity < sets humidity B - humidity B return difference, the relay B off, the indicator light B out.