FY2300FY6300 dual channel DDS function arbitrary waveform signal generator signal source frequency count
FY2300FY6300 dual channel DDS function arbitrary waveform signal generator signal source frequency count
FY2300FY6300 dual channel DDS function arbitrary waveform signal generator signal source frequency count
FY2300FY6300 dual channel DDS function arbitrary waveform signal generator signal source frequency count

FY2300FY6300 dual channel DDS function arbitrary waveform signal generator signal source frequency count

Price:   $154.65

  • Model: ic0A757
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)

Please Choose:

  • Indicator
  • Indicator 1 ch alarm
  • LCD
  • LCD 1 ch alarm
(complete orders today,deliverd around 26/04/2025)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    5S 21V 4.2V Balance Function Protection Board 68mA 5S Li-ion Lipo Battery Lithium 18650 Batteries Balanced 3S 4S 5S 6S 7S 8S
    $1.18
    ESP32 ESP32S For Wemos For Raspberry Pi 18650 Battery Charge Shield Board V3 Micro USB Port Type-A USB 0.5A For Arduino Charge
    $2.18
    40PCS MINGYUANDINGYE Dupont Line 1020cm Male to Male + Female to Male and Female to Female Jumper Wire Dupont Cable
    $0.80
    TDA2030 Module Power Supply TDA2030 Audio Amplifier Board Module TDA2030A 6-12V Single
    $0.64
    • Details
    • Reviews
    • Tags
    • FAQ
    Condition:New
    Type:Logic ICs
    Freight number:FY6300/FY2300
    Decoration and construction contents:Installation engineering

    The main differences between FY6300 andFY2300 are as follows:

    1. The highest output frequency of FY6300 series sinusoidal wave can reach 60MHz (FY6300-60M), and the highest output frequency of square wave can reach 25MHz.The detailed parameter index can refer to the corresponding parameter list of different models.

    2, add AM, FM, PM, ASK, FSK, PSK, VCO modulation function!

    3, the FY6300 series sampling rate is upgraded to 250MSa/s, and the output profile of the HF signal is clearer.

    4. FY6300 series uses 14-bit high-speed DA integrated circuit (performance far exceeds the DA scheme built by resistance network). When 5V output, the waveform step is as low as 0.3mV.

    5, FY6300 series of each waveform storage depth upgrade to 8192*14bits, high precision restore signal details;

    6, the FY6300 phase resolution can reach 0.01 degrees, and users can control the delay of the two signals more accurately.

    7, FY6300 series duty cycle adjustment accuracy can reach 0.01%.The time of rising and falling edges of square wave can be adjusted. When setting the output of square wave, pressing the F4 button can switch between duty cycle and setting the time of rising and falling edge, so that the instrument can be used more widely.

    8. FY6300 series adopts a new power supply design scheme, which eliminates the malpractice of hand-held instrument power supply noise interfering with small amplitude signals. (10mV's small signal still has the perfect signal characteristic).



    FY2300A series of dual-channel function/arbitrary waveform generator is a portable, high performance, high cost performance, multi-function signal generator, which integrates functions of function signal generator, arbitrary waveform generator, pulse signal generator, frequency sweeper, counter and frequency meter. The instrument uses large-scale FPGA integrated circuit and high-speed MCU microprocessor. The internal circuit uses high-precision active crystal oscillator as the reference, and the signal stability is high. The surface mount technology greatly improves the anti-interference and service life of the instrument. The instrument has completely independent dual DDS signal and TTL level output. It not only presets 31 common waveform signals for users, but also provides 16 groups of custom waveform storage space for users. This instrument achieves the perfect combination of easy-to-use, excellent technical indicators and many functional characteristics in signal generation, waveform scanning, parameter measurement and use. It can help users accomplish their tasks faster. It is an ideal test and measurement equipment for electronic engineers, electronic laboratories, production lines, teaching and scientific research.

    FY2300Series of dual-channel function/arbitrary waveform generators have humanized keyboard layout and instructions, providing users with an intuitive operation interface. The display interface is a 2.4 inch TFT color LCD screen with 320*240 high resolution. It can display all parameters of two channels at the same time and prompt the current button function. The shortcut key greatly simplifies the complex operation process and greatly enhances the operability of the instrument. Users do not have to spend a lot of time learning and familiar with the operation of the instrument, so they can use it skillfully.

    Reminder:In order to better integrate product line, some product naming rules are adjusted. The name of FY2300A is now adjusted to FY2300. Please know!



    1, internal circuit display


    2, display interface

    Our productsAMulti function interface:Each function has an independent interface, the display content is more abundant, the user operation is more intuitive, and the key reuse is greatly reduced. (for example: scan function interface. It can display all the information of scanning object, starting frequency, scanning time and scanning mode in one interface at the same time. Users can operate intuitively and observe the current scanning working state.

    3. Waveform reappearance function

    Our effect:The industry creates the waveform reappearance function.All waveforms output by the instrument can be displayed on the signal generator, including not only 31 preset waveforms, but also user-defined waveforms, which can be separated from the oscilloscope to a certain extent.Example: through the waveform drawing window of FY2300 PC, a waveform is drawn manually to download the instrument output.

    We all know the most important parameters of a signal: waveform, frequency, amplitude and offset. These are the most basic and closely related to hardware.

    1. About offset level:In many situations of debugging circuit, the bias signal needs to be adjusted arbitrarily. For example, debugging comparator circuit, a DC component needs to be superimposed on a small signal, and the value of the DC component is arbitrary (for example, the peak value of the signal is 0.5V, the DC component needs to be superimposed on 2V).

    Our bias: it can be adjusted anywhere from -10V to +10V.

    2, about small signal:Our 10mV and 5mV small signal


    With our FYV2000 series or FPA1000 series power amplifiers, the signal can output more than 20W undistorted power signal stably in the DC-3MHz bandwidth, and the maximum output power of FPA1016 can reach 60W.

    Multi function PC software:With arbitrary waveform editing function, it can edit arbitrary waveform on PC and download it to the instrument and output waveform. All functional parameters of the instrument support upper computer software control, and communication protocol is open, which makes your secondary development very simple. The upper computer software interface is as follows:

    Multifunctional handheldportableAnd other advantages:It only needs a mobile power supply to work outdoors for a long time, realizing the function of desktop signal source with the smallest body..


    Warm reminder: FY2300 series signal generator and FY6300 series signal generator parameters are different, the following are listed in two series of product parameters indicators, there is no clear place you can contact us at any time!



    The parameters of FY2300 series signal generator are as follows:










    1.CH1 channel output10KHzSine wave,CH2 channel outputs 10KHz triangle wave.Instrument outputOscillographmeasureFrequency is exactly the same. In fact, we have done accurate on-line calibration, which can make the frequency output exactly the same.



    2, CH1 channelOutput frequency is100KHz,Fang Bo with a duty ratio of 20%;CH2passagewayoutput100KHz,Duty cycle80% of Fang Bo;Duty cycle in square wave modeOptional settingsIn order to generate a pulse wave with adjustable duty ratio, the precision of adjustment is accurate to 0.1%.


    3.CH1 channelThe output 1MHz amplitude is4V, offset sine wave of 6V.;CH2passagewayoutput1MHzAmplitude is4V, offset sine wave of -6V.(output signal bias level can be adjusted between -10V and +10V).


    4, CH1Channel outputSmall signal with a magnitude of 100mV.CH2 channel small output signal of 50mV



    5, CH1Channel outputAmplitude is10mVSmall signal,CH2 channel small output signal of 5mV




    6. In the square wave output state,Adjust bias level,The instrument can output digital signals.At the same time, the amplitude of the digital signal can also be adjusted.instrumentYou can export 1.2V.,1.5V, 1.8V, 3.3V,5V,10Vetc.Arbitrary range of 0~10VCMOS level.As shown in the following figure:The CH1 channel output amplitude is 5V COMS level, and the CH2 channel output amplitude is 10V COMS level.


    7.Burst burst output function:Three trigger modes, manual trigger, internal CH2 trigger and external trigger, can make the local machine output 1 ~ 1048575 arbitrary pulse train, pulse train type, and external trigger.Number of pulsesThe trigger mode can be set by users.


    8. Cymometer function: It has five measurement modes: frequency measurement, period measurement, positive pulse width measurement, negative pulse width measurement and duty cycle measurement. The five measurement modes can be carried out simultaneously and displayed in real time. Gate time 1S, 10S, 100S three optional. The maximum frequency of the instrument can reach 100MHz, and the minimum measuring frequency is 0.01Hz.

    Examples are:

    (1),measureFY3200SOutput of series signal sourceFrequency1KHzThe duty cycle is25% square wave signal,Gate time selection1S,The measurement results are shown in the following figure:

    The measured frequency is 1000Hz (gate time is 100S, and the result is accurate to 0.01Hz).

    Measurement signal cycleDisplay as1000000nsThe frequency and the cycle of our instruments are two different ways of measurement. The minimum frequency can be measured.0.01Hz, the maximum cycle is measured to 20S.)

    The positive pulse time of the square wave with duty ratio of 25% is measured, and the measured result is 2500.00ns

    The negative pulse time of the square wave with duty ratio of 25% is measured, and the measurement result is 75000.0ns

    Measuring the duty cycle of the square wave, the result is 25%.


    (2)measure0.02Fang Bo of Hz,Gate time selection100S,measurement result0.02Hz, not bad at all.


    9.Counterfunction:It has two coupling measurement methods of DC and AC, which can effectively solve the problem of inaccurate counting of AC coupling.Can pressStart keyCount.Pause keyYou can pause the count.Clear zero keyCan be cleared and counted again.. In counting state, the instrument can also measure signal cycle, pulse width and duty cycle at the same time. As shown in the following figure:


    10.Two or more machines can achieve multi machine synchronization through the TTL_IO port.The phase of each output waveform is 0-359 degree adjustable.. Example: Two instruments work at the same time, one instrument synchronizes with the other instrument, and outputs four sinusoidal waves with the same frequency and 90 degrees of phase difference at the same time.



    11, CH1 channeloutputSine wave with frequency of 10MHz



    12, CH1 channel output frequency of 20MHz sine wave.



    13, CH2 channel output1MHz, sine wave of 20V amplitude.

    14, CH1 channel output10KHz literSawtooth wave,CH2 channel output 10KHzdropSawtooth wave



    15. The tracking function of the instrument can be realized.Two channel waveform, frequency, amplitude, offsetandDuty cycleSynchronization of parameters, each physical quantity can be set independently or canceled. Example: when the waveform, frequency, amplitude and offset are synchronized, the instrument is adjusted.CH1 channelWaveform, frequency, amplitude and bias parameter.CH2The corresponding parameters of the channel also change synchronously. The following figure showsThe CH1 channel and CH2 channel output frequency is 10KHz, the amplitude is 10V, and the bias is 0V.The phase difference is 90 degrees.Sine wave.



    16.CH1 channelandCH2 channelAt the same time, the output frequency is10KHz,The phase difference is 180 degrees.The square wave signal,When driving modules such as IGBT, it is sometimes necessary to drive rectangular pulse wave with adjustable duty cycle, which is opposite to each other. The maximum output range of this machine is 10V, the output impedance is 50ohm, and even the gate G of VMOS power transistor can be directly driven. Whether it can be directly driven depends on the specific conditions.



    17. The Li Shayu figure with a phase difference of 180 degrees shows that the figure is a very stable straight line.



    18. By adjusting the output parameters of the two channels of the instrument, different Lishayu graphs can be realized, as shown in the following figure:






    1931162048*12bits