High precision hydrogen sulfide H2S sensor transmitter RS485 Modbus digital buzzer relay
High precision hydrogen sulfide H2S sensor transmitter RS485 Modbus digital buzzer relay
High precision hydrogen sulfide H2S sensor transmitter RS485 Modbus digital buzzer relay
High precision hydrogen sulfide H2S sensor transmitter RS485 Modbus digital buzzer relay

High precision hydrogen sulfide H2S sensor transmitter RS485 Modbus digital buzzer relay

Price:   $115.18

  • Model: ic0A3352
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)
(complete orders today,deliverd around 11/07/2024)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    GY-521 MPU-6050 MPU6050 Module 3 Axis gyro sensors+ 3 Axis Accelerometer Module
    $1.37
    Conversion board for for Raspberry Pi to HUB75 for Raspberry Pi GPIO controlled RGB LED display
    $1.81
    1 Set OV2640 2.0 MP Mega Pixels 14'' CMOS Image Sensor SCCB Interface Camera Module Electronic Integrated Module
    $1.36
    CT14 Micro 4.2 Stereo for Bluetooth Power Amplifier Board Module 5VF 5W+5W Mini with Charging Port for Refitting Idle Sound Box
    $1.18
    • Details
    • Reviews
    • Tags
    • FAQ
    Condition:New
    Type:Logic ICs


    High-precision hydrogen sulfide H2S sensor transmitter RS485 Modbus digital buzzer relay



    A:High-precision



    B:High-precision + indicator light



    C:High-precision + LCD screen



    D:High-precision + indicator light + 1-channel alarm



    E:High-precision + indicator light + 2-channel alarm



    F:High-precision + LCD screen + 1-channel alarm



    G:High-precision + LCD screen + 2-channel alarm



    H:Add stainless steel bellows



    O1CN01JRdvCx1DKiuMN4Bw8_!!0-item_pic






    First, product introduction



    The transmitter has built-in multiple protection against lightning, anti-reverse, over-current, etc. The product is fully interchangeable and is used to accurately measure the concentration of hydrogen sulfide. The transmitter acts as a slave to transmit the air pressure through the industrial universal interface RS485. The software was developed in full compliance with the standard MODBUS RTU serial communication protocol. It can be well compatible with WINCC, Kingview, Force Control, Kunlun Tongzhou, touch screen, PLC and other PC configuration software and hardware, as well as software or hardware developed by third parties according to the standard MODBUS RTU protocol. And optional LCD screen display measurement data, after the limit of the buzzer sound alarm prompt, after the limit of the alarm relay drive alarm device action and other functions. This transmitter can supply and communicate with only one 4-core communication cable to transmit sensor data remotely. It can save a lot of cables on the construction site, and the price advantage is very obvious.



    Second, technical parameters



    Project|parameter


    Detection gas|hydrogen sulfide (H2S)


    Range|0~100ppm


    Maximum measurement limit | 500ppm


    Sensitivity|(0.8±0.15) uA/ppm


    Resolution 0.1ppm


    Response time (T90)|<30S


    Bias |0mV


    Load resistance (recommended)|10Ω


    Repeatability|<2% out


    Stability (/month|<2%


    Output linearity | linear


    Zero drift (-20 ° C ~ 40 ° C) | ≤ 0.2ppm


    Temperature range | -20 ° C ~ 50 ° C


    Humidity range|15%-90%RH


    Pressure range|standard atmospheric pressure ±10%





    Range can be customized









    Working temperature: -20~60°C, @5~95%RH





    Storage temperature: -25~80°C





    Supply voltage: DC 7~24V, recommended: DC12V





    Maximum power consumption: 100mA@12V with LCD (0802)





    Display mode: LED indicator or LCD screen





    LCD screen specifications: LCD0802 8 characters * 2 lines





    Communication interface: RS485





    Communication protocol: MODBUS RTU





    Communication rate: Software settings, 2400, 4800, 9600, 19200, 38400, 115200, etc. Default 9600bps





    Data format: default 8N1 (1 bit start bit, 8 data bits, 1 stop bit, no parity)





    Communication mode: The transmitter acts as a MODBUS RTU slave station, and the master station (touch screen, PLC, host computer, etc.) uses the master-slave polling method to query the real-time data of the transmitter.





    Node address: 1~255, DIP switch or software setting





    Number of nodes: theoretically up to 128 transmitters on the same bus, the actual application takes up 1/2~2/3





    Transmission distance: 1000 meters (RS485 communication dedicated cable)





    The transmitter has been treated three times before leaving the factory to ensure long-term use under high temperature and high humidity special soil.





    Installation method: wall-mounted





    Product size: 115*80*40 mm








    Third, the method of use






    Hardware parts:





    First plug the network cable into the waterproof Ethernet interface of the product, and connect the other end to the computer or router, hub, switch, etc., then connect your own switching power supply or the power adapter of the product to the power cable, or directly connect the power adapter to the DC. Plug the plug into the reserved power hole of the product.





    Software parts:


    According to your own system, choose to install 32-bit or 64-bit software. Generally, you only need to install modbus poll software. The following takes the WIN10 64-bit system as an example.

    Click: I accept the terms of the license Agreement ---> Next ---> Next ---> Install ---> Next ---> Cancel the check box before Show Readme - ---> Finish

    After the above steps, the software installation is complete.
    11
    12
    13
    14
    15


    Power on the device. After a few seconds of product initialization, open the test file provided by the company, you can see the data collected by the transmitter, as shown below.
    20190819123230


    Modify the alarm value upper limit, lower limit, transmitter address, baud rate, check digit and other parameter methods to modify the transmitter address as an example





    1 Mouse directly double-click the desired transmitter address value, ie 1, the following interface pops up:


    16





    2 Modify the value behind 1 to the actual required value, the range 1~253, 254 is the universal query address, address 254, only suitable for the case where the bus has only one device. Here we set the value of 1 to 3, and then click the Send button, the address of the current device, you can change to 3, the device does not need to power off, the new value automatically takes effect.


    16





    In order to better understand and learn the MODBUS RTU/TCP protocol, click on the menu bar Display--->Communication, you will see the instructions from the computer to get the data and the data returned by the transmitter; TX is the command issued by the computer. RX is the data returned by the transmitter


    18






    Six, matters needing attention






    1. The transmitter is equipped with no test power supply and RS485 converter. If necessary, please contact the customer to purchase or purchase it yourself!





    2. The power supply voltage and output current used must meet the requirements, otherwise the product may be damaged or may not work properly.





    3. When connecting the transmitter cable, be careful not to connect it incorrectly, otherwise it may burn internal components or not work properly.





    4. Please use RS485 special cable as much as possible to improve transmission distance and stability.





    5. The transmitter station address setting must not be duplicated with other slave addresses.





    6. The transmitter has built-in 120Ω termination resistor. When the transmitter is at the end of the 485 bus, please close the S3 shorting sleeve.





    7, the transmitter slave station no more than 31, otherwise need to add RS485 bus bridge (relay), and the main station MODBUS RTU / TCP protocol, baud rate and other data formats must be consistent.





    8. The default communication baud rate is 9600bps and 8N1 data format when the product leaves the factory. If the user needs to modify the baud rate or data format, we provide the program software to modify it.