MBus to Ethernet Modbus-TCP MODBUS-RTU can connect 500 meters Support meter protocol customized
MBus to Ethernet Modbus-TCP MODBUS-RTU can connect 500 meters Support meter protocol customized
MBus to Ethernet Modbus-TCP MODBUS-RTU can connect 500 meters Support meter protocol customized
MBus to Ethernet Modbus-TCP MODBUS-RTU can connect 500 meters Support meter protocol customized
MBus to Ethernet Modbus-TCP MODBUS-RTU can connect 500 meters Support meter protocol customized
MBus to Ethernet Modbus-TCP MODBUS-RTU can connect 500 meters Support meter protocol customized

MBus to Ethernet Modbus-TCP MODBUS-RTU can connect 500 meters Support meter protocol customized

Price:   $88.86

  • Model: ic0A083
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)

Please Choose:

  • orange
  • Red
  • WHITE
  • Blue
  • green
(complete orders today,deliverd around 26/04/2025)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    MAX6675 Module + K Type Thermocouple Thermocouple Senso Temperature Degrees Module for arduino
    $2.00
    1-2pcs 100%New NCV8843MNR2G NCV8843 DFN-18
    $1.90
    8-channel high-speed pulse counting frequency acquisition module 3-channel forward and reverse encoder to Ethernet Modbus TCP
    $159.65
    18650 lithium battery digital display charging module 5v2.4a 2A dual USB output band display booster module
    $1.73
    • Details
    • Reviews
    • Tags
    • FAQ
    Condition:New
    Type:Logic ICs

    1.2 Product introduction

    This is a high-performance dual converter with bus interface and communication protocol. On the bus interface, the M-BUS bus to Ethernet/RS485 is realized. In terms of communication protocol, CJ/T-188, European standard first-level address MBUS protocol, European standard second-level address MBUS protocol, and user-defined protocol to standard MODBUS-TCP or MODBUS-RTU are realized, and it also supports server and instrument communication Transparent transmission. The user can obtain the data of various MBUS meters connected to the converter by reading the registers with the MODBUS-TCP/MODBUS-RTU protocol through the Ethernet/RS485 interface. The converter realizes the conversion function of the physical layer and the protocol layer at the same time. Its built-in isolation circuit can effectively protect the equipment connected to the serial port;

    It has carried out multiple protection and filtering processing on the M-BUS end, which can provide stable, safe and strong anti-interference ability of M-BUS communication; it has been obtained in thousands of engineering practices and practical use.

    To wide acclaim.

    This converter is suitable for any MODBUS master station to read the data of M-BUS equipment. The converter uses the MODBUS-RTU protocol to support the reading of 100 pieces of instrument data. At the same time, the converter also supports the transparent transmission mode. The transparent transmission mode can realize the transparent transmission between the host and the M-BUS slave. The transparent transmission mode supports up to 500 Block meter.


    1.3 Product features

    ? DC 9V~24V wide voltage input

    ? High-power M-BUS host interface, which can support up to 500 standard loads

    ? Support devices of different manufacturers, different protocols and different serial port parameters to connect to the same converter

    ? Support transparent transmission function, which is convenient for the host to directly communicate with the instrument or on-site debugging

    ? Abundant indicator lights, the operating status of the equipment is clear at a glance

    ? Support on-site firmware design to facilitate on-site addition and modification of communication protocols

    ? Provide configuration software