Noise DB Decibel Noise Sensor Transmitter RS485 Modbus High Precision
Noise DB Decibel Noise Sensor Transmitter RS485 Modbus High Precision
Noise DB Decibel Noise Sensor Transmitter RS485 Modbus High Precision

Noise DB Decibel Noise Sensor Transmitter RS485 Modbus High Precision

Price:   $169.53

  • Model: ic0A2835
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)
(complete orders today,deliverd around 11/07/2024)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    10pcs 100% orginal new in stock M5L8279 M5L8279P-5 DIP40 feet in-line display interface chip
    $18.00
    5pcs 100% orginal new CS5528 CS5528ASZ CS5528-ASZ SSOP24 analog-to-digital converter chip
    $95.00
    10pcs 100% orginal new in stock INA188IDR INA188 SOIC8 zero drift rail-to-rail output instrumentation amplifier chip
    $16.01
    10pcs 100% orginal new in stock memory chip K6T1008C2E K6T1008C2E-GB70 SOP-32
    $11.47
    • Details
    • Reviews
    • Tags
    • FAQ
    Condition:New
    Type:Logic ICs


    Dust concentration transmitter



    A:High Precision(Without indicator and LCD screen)



    B:High Precision + indicator light



    C:High Precision + LCD screen



    D:High Precision + indicator light + 1-channel alarm



    E:High Precision + LCD screen + 1-channel alarm



    F:High Precision + LCD screen + 2-channel alarm



    O1CN011DKit3lrvpLJ7Cf_!!0-item_pic






    First, product introduction



    The transmitter core module noise sensor is a direct-reading noise decibel detection module developed by the original imported sound sensor. Multi-point calibration process, high detection accuracy and high sensitivity Unique stainless steel probes are individually packaged and designed to be easily embedded in other equipment or enclosures! The main control board circuit core device is completely shielded, not only beautiful and more anti-interference ability. Reserved a variety of output TTL / I2C, standard Modbus Rtu communication 485 interface optional, suitable for a variety of application integration.



    The noise transmitter is built with multiple protections such as lightning protection, anti-reverse connection and over-current. The product is fully interchangeable and is used to accurately measure soil temperature and humidity. The transmitter acts as a slave to transmit noise through the industrial universal interface RS485. The software was developed in full compliance with the standard MODBUS RTU serial communication protocol. It can be well compatible with WINCC, Kingview, Force Control, Kunlun Tongzhou, touch screen, PLC and other PC configuration software and hardware, as well as software or hardware developed by third parties according to the standard MODBUS RTU protocol. And optional LCD screen display measurement data, after the limit of the buzzer sound alarm prompt, after the limit of the alarm relay drive alarm device action and other functions. This transmitter can supply and communicate with only one 4-core communication cable to transmit sensor data remotely. It can save a lot of cables on the construction site, and the price advantage is very obvious.


    Application:


    Can be widely used in: noise monitors, detectors, automation control systems, environmental noise monitoring systems, industrial, plant and other places that need to be measured.


    Feature:



    Measuring range 30~120dB





    Frequency range 20Hz ~ 12.5kHz





    Output Type RS485





    Maximum error 0.5dB





    Working temperature -20 ° C ~ 70 ° C





    Relative humidity 25% to 90%





    Air pressure 65KPa ~ 108KPa





    Stability is less than 2% in use period





    Reaction time is less than 3s





    Protection level IP54





    Storage conditions -40~70°C (-40~158°F)





    Supply voltage: DC 7~24V, recommended: DC12V





    Maximum power consumption: 100mA@12V with LCD (0802)





    Display mode: LED indicator or LCD screen





    LCD screen specifications: LCD0802 8 characters * 2 lines





    Communication interface: RS485





    Communication protocol: MODBUS RTU





    Communication rate: Software settings, 2400, 4800, 9600, 19200, 38400, 115200, etc. Default 9600bps





    Data format: default 8N1 (1 bit start bit, 8 data bits, 1 stop bit, no parity)





    Communication mode: The transmitter acts as a MODBUS RTU slave station, and the master station (touch screen, PLC, host computer, etc.) uses the master-slave polling method to query the real-time data of the transmitter.





    Node address: 1~255, DIP switch or software setting





    Number of nodes: theoretically up to 128 transmitters on the same bus, the actual application takes up 1/2~2/3





    Transmission distance: 1000 meters (RS485 communication dedicated cable)





    The transmitter has been treated three times before leaving the factory to ensure long-term use under high temperature and high humidity special soil.





    Installation method: wall-mounted





    Product size: 115*80*40 mm


    Second, technical parameters


    Supply voltage: DC 7~24V, recommended: DC12V

    Maximum power consumption: 100mA@12V with LCD (0802)

    Display mode: LED indicator or LCD screen

    LCD screen specifications: LCD0802 8 characters * 2 lines

    Communication interface: RS485

    Communication protocol: MODBUS RTU

    Communication rate: Software settings, 2400, 4800, 9600, 19200, 38400, 115200, etc. Default 9600bps

    Data format: default 8N1 (1 bit start bit, 8 data bits, 1 stop bit, no parity)

    Communication mode: The transmitter acts as a MODBUS RTU slave station, and the master station (touch screen, PLC, host computer, etc.) uses the master-slave polling method to query the real-time data of the transmitter.

    Node address: 1~255, DIP switch or software setting

    Number of nodes: theoretically up to 128 transmitters on the same bus, the actual application takes up 1/2~2/3

    Transmission distance: 1000 meters (RS485 communication dedicated cable)

    The transmitter has been treated three times before leaving the factory to ensure long-term use under high temperature and high humidity special soil.

    Installation method: wall-mounted

    Product size: 115*80*40 mm







    Third, the method of use






    Hardware parts:





    First plug the network cable into the waterproof Ethernet interface of the product, and connect the other end to the computer or router, hub, switch, etc., then connect your own switching power supply or the power adapter of the product to the power cable, or directly connect the power adapter to the DC. Plug the plug into the reserved power hole of the product.





    Software parts:


    According to your own system, choose to install 32-bit or 64-bit software. Generally, you only need to install modbus poll software. The following takes the WIN10 64-bit system as an example.

    Click: I accept the terms of the license Agreement ---> Next ---> Next ---> Install ---> Next ---> Cancel the check box before Show Readme - ---> Finish

    After the above steps, the software installation is complete.
    11
    12
    13
    14
    15


    Power on the device. After a few seconds of product initialization, open the test file provided by the company, you can see the data collected by the transmitter, as shown below.
    20190819123230


    Modify the alarm value upper limit, lower limit, transmitter address, baud rate, check digit and other parameter methods to modify the transmitter address as an example





    1 Mouse directly double-click the desired transmitter address value, ie 1, the following interface pops up:


    16





    2 Modify the value behind 1 to the actual required value, the range 1~253, 254 is the universal query address, address 254, only suitable for the case where the bus has only one device. Here we set the value of 1 to 3, and then click the Send button, the address of the current device, you can change to 3, the device does not need to power off, the new value automatically takes effect.


    16





    In order to better understand and learn the MODBUS RTU/TCP protocol, click on the menu bar Display--->Communication, you will see the instructions from the computer to get the data and the data returned by the transmitter; TX is the command issued by the computer. RX is the data returned by the transmitter


    18






    Six, matters needing attention






    1. The transmitter is equipped with no test power supply and RS485 converter. If necessary, please contact the customer to purchase or purchase it yourself!





    2. The power supply voltage and output current used must meet the requirements, otherwise the product may be damaged or may not work properly.





    3. When connecting the transmitter cable, be careful not to connect it incorrectly, otherwise it may burn internal components or not work properly.





    4. Please use RS485 special cable as much as possible to improve transmission distance and stability.





    5. The transmitter station address setting must not be duplicated with other slave addresses.





    6. The transmitter has built-in 120Ω termination resistor. When the transmitter is at the end of the 485 bus, please close the S3 shorting sleeve.





    7, the transmitter slave station no more than 31, otherwise need to add RS485 bus bridge (relay), and the main station MODBUS RTU / TCP protocol, baud rate and other data formats must be consistent.





    8. The default communication baud rate is 9600bps and 8N1 data format when the product leaves the factory. If the user needs to modify the baud rate or data format, we provide the program software to modify it.