Condition:New
Type:Logic ICs
Original authentic Tyco relay EV200AAANA
Due to EV200relaySmall size, contact current is quite high, therefore suitable for batteryswitchBackup DCVoltageThe power control circuit, protection and security applications. The built-incoilSave the device in the 12Vdc, only 1.7W to maintain power, so the backward EMF limit to zero voltage. The coil connection can be realized through the connector jumper or optional. Optional auxiliary contacts can be used to monitor the electrical contact position. The life of the mechanical EV200relay for the 1 million time, the normal operating temperature range of -40 to 85 DEG C. These relays meet CE requirements for EC applications, they also comply with the AIAG QS9000 index, through the United States and Canada UL E208033 document authentication. Dimensions: 2.58 "x 3.17" x 2.85 "tall
Due to EV200relaySmall size, contact current is quite high, therefore suitable for batteryswitchBackup DCVoltageThe power control circuit, protection and security applications. The built-incoilSave the device in the 12Vdc, only 1.7W to maintain power, so the backward EMF limit to zero voltage. The coil connection can be realized through the connector jumper or optional. Optional auxiliary contacts can be used to monitor the electrical contact position. The life of the mechanical EV200 relay for the 1 million time, the normal operating temperature range of -40 to 85 DEG C. These relays meet CE requirements for EC applications, they also comply with the AIAG QS9000 index, through the United States and Canada UL E208033 document authentication. Dimensions: 2.58 "x 3.17" x 2.85 "tall
Main purpose: electric vehicle / ship / industrial equipment / test equipment for high power / mining machinery / power equipment / environmental control / light electric vehicle, electric vehicles, electric commercial vehicles, electric off-road vehicles, electric buses etc.
EV200 seriesThe following is the specific model
EV200AAANA
EV200ADANA
EV200ADANA
EV200HAANA
9-1618389-5
EV200HDANA
EV200HJANA
EV200HRANA
EV200A1XXA03
EV200AAACA02
EV200AAAJA01
EV200AXANA02
EV200B5ANA
EV200BAANA
EV200GAANA
EV200HRANA02
EV200P4ANA
seriesSeries | LEV100/200 | EV200 | EV250 | EV500 | K61/81 |
modelType | LEV100 (200): A4LEV100 (200): A5LEV100 (200): A6LEV100 (200): H4LEV100 (200): H5LEV100 (200): H6 | EV200AA---EV200AD---EV200AJ---EV200HA---EV200HD---EV200HJ--- | EV250-1AEV250-1BEV250-2AEV250-2BEV250-5A | EV500-4AEV500-4BEV500-5AEV500-5B | K61A---K61B---K61C---K81C--- |
Safety certificationAgency Approval | - | | - | - | - |
contact formContact Form | A= normally openH= normally open + auxiliary contactsA=Normally OpenH=Normally Open with Aux. Contacts | - | 4= auxiliary contact5= assistantcontact4=No Aux. Contacts5=with Aux. Contacts | A=SPST-NOB=SPST-NCC=SPDT |
RatedVoltageRated Operating Voltage | 12-900 VDC | 12-900 VDC | 28-1800VDC | 28-1800VDC | 10KV/ K6125KV/ K81 |
Continuous carryingelectric currentContinuous (Carry) Current, Typical | 500Amps 65 C | 500Amps 85 C | 400Amps500Amps/6 minutes | 600A270VDC, 85 C1600A/10 seconds | 6AmpsDC/60Hz |
Disconnect current 320VDCBreak Currents | 2000Amps | 2000Amps | 2500Amps | 3300Amps | - |
Typical / maximum contact resistanceContact Resistance,Typ./ Max. | 0.2 200A M. | 0.2 200A M. | 0.0003. | 0.0002. | 0.05 / 0.5. |
Mechanical lifeMechanical Life | 100000 times | 1000000 times | - | - | - |
auxiliarycontactThe maximum contact currentAux. Contact Current Max. | 2A30VDC3A125VAC | 2A30VDC3A125VAC | - | - | - |
The minimum contact current of auxiliary contactsAux. Contact Current, Min. | 100mA8V | 100mA8V | - | - | - |
auxiliarycontactMaximum contact resistanceAux. Contact Resistance Max. | 0.41730VDC0.150125VAC | 0.41730VDC0.150125VAC | - | - | - |
insulationresistance500VDCInsulation Resistance | 100 M. | 100 M. | 100 M. | 100 M. | - |
temperature rangeOperating AmbientTemperature | -40 ~ 65 C | -40 ~ 85 C | -40 ~ 85 C | -40 ~ 85 C | -55 ~ 85 C |
The nominal weight (kg)Weight, Typical | Zero point six zero | Zero point four three | 0.7 kg / 0.8 kg | 1.53kg | - |
coildataCoilOperatingVoltage | nominalVoltageCoil Voltage | 4=12VDC5=24VDC6=48VDC | A=9-36VDCD=32-95VDCJ=48-95VDC | A=12VDCB=24VDC | A=12VDCB=24VDC | 2=12VDC3=26.5VDC5=115VDC |
VoltageRangeVoltage(will operate) | 9.6-13.2VDC19.2-26.9VDC38.4-52.8VDC | A=9-36VDCD=32-95VDCJ=48-95VDC | - | - | - |
The maximum voltageVoltage Max. | 15VDC30VDC60VDC | 36VDC95VDC95VDC | - | - | - |
The maximum pick upVoltagePickup (close)Voltage Max. | 9.6VDC19.2VDC38.4VDC | 9VDC32VDC48VDC | -1A/B: 8.3/ 16.6VDC-2A/B: 9/ 18VDC-5A: 9VDC | 9.9VDC19.7VDC | 8VDC16VDC80VDC |
installationMounting Terminals | Bottom / sideBottom/ Side | bottomBottom | pc boardPC Board |
Connection modeTerminal Options | Bolt / leadMale 10mm * M8 Threaded Terminals/ Wires | BoltMale 10mm * M8 Threaded Terminals | Lead wire, pinWires/ Pin Terminals |
high pressuredirectContactorWidely used in power supply:
1,Police vehicles and artillery control unit
Armored vehicles, artillery and tanks, amphibious vehicles, supply trucks, * * bulldozer, dump truck, crane equipment and services
2,Aviation, aerospace, space station distribution equipment and ground towing vehicle
3,Sea ship/Ships and underwater equipment (DCPower)
4,Hybrid vehicle-Truck, bus, rail vehicle
The power cut off, auxiliary power connection, and diesel heaterDCconnect