Refrigeration piece 19908 high power 40*40 24V8A high temperature 237 degree temperature difference of 69 degrees outlet condens
Refrigeration piece 19908 high power 40*40 24V8A high temperature 237 degree temperature difference of 69 degrees outlet condens
Refrigeration piece 19908 high power 40*40 24V8A high temperature 237 degree temperature difference of 69 degrees outlet condens
Refrigeration piece 19908 high power 40*40 24V8A high temperature 237 degree temperature difference of 69 degrees outlet condens

Refrigeration piece 19908 high power 40*40 24V8A high temperature 237 degree temperature difference of 69 degrees outlet condens

Price:   $23.55

  • Model: ic0A1792
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)

Please Choose:

  • With BT kits
  • Silver kits
  • BT Finished
  • Silver Finished
  • Black kits
  • Portable kits
  • Black finished
  • Portable Finished
(complete orders today,deliverd around 25/04/2025)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    1PCSlot RTL8111G 8111G QFN-32 Chipset 100% new imported original IC Chips fast delivery
    $3.50
    Single Chip Amplifier Pma-545g2 Pma-545g2 1.1-1.6ghz Original Genuine 1pcs
    $8.00
    1PCSlot LPC2214FBD144 LPC2214FBD14401 LPC2214FBD14401,5 IC MCU 1632B 128KB FLSH 144LQFP IC Chip New original
    $4.49
    New original CAP1203-1-SN-TR CAP1203 SOP-8 capacitive touch sensor chip
    $0.79
    • Details
    • Reviews
    • Tags
    • FAQ
    Color classification:white





    Direct sales, sHop for tHe factory opening ceremony, not for profit, only for the credibility, quality of the whole network is highest, more than 50 pieces of mail bag!

    Solemnly promise, as long as you find in other shops ofTaobao's refrigerator Beav electronic cooling with high quality, we are at the lowest price to sell taobao.com, please contact customer service! Seven days no reason to return!




    • Basic electrical performance index





























































    term order




    specialnaturevalue




    strip piece




    Maximum temperature difference current




    IMax




    8.0A




    Th=30C




    Maximum temperature difference voltage




    VMax




    24.6V




    Th=30C




    Maximum temperature difference




    DeltaTMax




    More than68C




    Qc=0T.h=30C




    Maximum cooling power




    QCmax




    111W




    DeltaT=0C, Th=30C




    Temperature range




    TR




    -60~200C








    Power supply wire




    UL1569 20AWG 105Standard tin plated wire,PVCInsulation leather, wire end peeling7.1mmLead solder at one end of the hot surface, lead length to the actual length of the assembly shop, also can be customized according to customer special requirements




    Bear assembly pressure




    98N/cm2




    Moisture and moisture treatment




    All around704Silicone rubber seal




    Storage condition




    ambient temperature-10C ~40The relative humidity is not more than80%Storage environment for ventilated and non corrosive gases










    Buyers notice:



    1 refrigeration slice is divided into cold, hot two sides. Refrigeration pieces are generally printed ascoldThe blank surface isheatNoodles



    2 refrigeration chip is generally loaded DC12V voltage (DC)!



    3 in the test of the refrigeration chip, there is no case of the radiator installed. Electricity can not exceed two seconds, otherwise it will burn. Responsible buyers themselves!






    A simple test method of cooling plate



    The operation method is: on the one hand pinch on both sides of the refrigerating sheet, on the other hand wire cooling pad on the two poles of the battery on the (According to the anode, the red black on cathode), if can feel a cold side heat, the cooling plate is good, can work normally.



    The use of cooling pad



    1 cooling plate working state is a cooling side heating, cooling plate in work must give the hot surface of good heat dissipation, no heat is strictly prohibited in the condition of electricity to the cooling plate more than 2 seconds, causing overheating burn buyers conceit. Through the electric refrigerating plate heat exchange when the hot and cold sides must be restored to room temperature (usually more than 5 minutes) can be broken, otherwise easy to cause line damage and the ceramic panel cooling plate.



    2 cooling plate is used as cooling, the red to the black power anode, the cathode of a power supply, switching power supply requires the use of ripple coefficient is less than 10%. The ceramic panel which is generally welded with a wire is a hot surface. If the red line of the cathode of a power supply, the black wire to the positive power supply, is the hot and cold face adjustable cooling plate.



    Not installed 3 radiator cooling plate heat surface, do not connect the power supply; bad heat surface heat will lead to high temperature than the hot surface of the cooling plate limit temperature of 100 degrees, resulting in overheating burn out cooling plate. Because the cooling plate is cooled by cold and hot surface temperature, so the heat surface temperature is lower, the surface temperature is lower, the cooling effect is better.



    The 4 is composed of two cooling plate ceramic panel and semiconductor material with low melting point solder combination, the intensity is not high, belongs to brittle materials, the user must ask gently, do not bump, but not fell from a height, to avoid the damage caused by the rupture of ceramic panel.



    Understanding cooling plate



    The naming rules of cooling plate type is composed of six parts. For example TEC1-12706



    The first part: TE thermoelectric module, is the abbreviation of Thermo-Electric English;



    The second part: structure category cooling plate, ceramic type cooling plate commonly used(The temperature difference electric component section area is larger than1mm2) by C, a small ceramic type thermoelectric module (also known as micro electric refrigeration componentsThermoelectric element is less than or equal to the cross-sectional area1mm2S said, there is a metal structure with M said;



    The third part: refrigeration sheet layers (Series), represented by a digital Arabia refrigeration piece from 1 layers to 6 layers ranging from more layers, the greater difference in temperature.



    The fourth part: logarithmic cooling plate galvanic (number of P and N nodes), represented by the three Arabia figures, as of 127.



    The fifth part: cooling plate allowed maximum temperature value of the current, represented by the two Arabia numbers, such as 06 6A current, the current limiting current in the load voltage limit is the best cooling condition, the temperature rises when the refrigeration component will lead to decline in value of current.



    The sixth part: the outer surface of the cooling plate, with no more than two bits English letters. Non metallization layer does not mean that one side of the metallization layer with T, the two sides of the metallization layer with TT.



    The practical application of the cooling plate



    In practical application, the 127 series (i.e. the number of 127 pairs of galvanic) voltage of the cooling plate general loading is 12V. For example: TEC1-12706, *0.12 logarithmic limit voltage for 127*0.12 = 15.4V thermocouple, normal working voltage is about 78% 15.4*78%=12V limit voltage, working current under normal operating voltage is about 78% of the maximum allowable current value is 6*78% = 4.7A, the voltage is low, current with low heat radiator cooling plate surface the higher the temperature, the current is low; the refrigerating sheet maximum cooling power = maximum allowable current value of galvanic log * *0.07=127*6*0.07 = 53W; cooling plate in the practical application of the temperature difference and the utilization rate of about 60% to 70% of the theoretical value, the heat cooling plate is the cooling plate power and cooling pad cooling capacity and so, if the heating cooling plate utilization rate of over 100%.