RS485 infrared carbon dioxide, CO2, illuminance, temperature, humidity, sensor, controller four in one

RS485 infrared carbon dioxide, CO2, illuminance, temperature, humidity, sensor, controller four in one

Price:   $283.86

  • Model: ic0A928
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)

Please Choose:

  • orange
  • Red
  • WHITE
  • Blue
(complete orders today,deliverd around 26/04/2025)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    50pcs 2010 5% 34W SMD Chip Resistor resistors 0R - 10M 0 10 100 220 470 ohm 0R 10R 100R 220R 470R 1K 2.2K 4.7K 10K 100K 1M 10M
    $0.93
    1PCS AT24C01A AT24C01A-10SU-2.7 SOP8 New Original Storage Chip
    $0.20
    100pcs 1206 50V SMD Thick Chip Multilayer Ceramic Capacitor 10pF- 100uF 10NF 100NF 1UF 2.2UF 4.7UF 10UF 22UF 47UF 100UF 22PF
    $1.85
    10pcslot Chip tantalum capacitor 6V 1000UF 6.3V E type 7343 108J bile capacitor bile capacitor yellow polarity
    $4.28
    • Details
    • Reviews
    • Tags
    • FAQ
    Type:Logic ICs
    Condition:New
    Color classification:white

    Product features

    YS9565B carbon dioxide, light intensity, temperature and humidity, the four in one sensor is RS485 bus type sensor. It is a special sensor for agricultural greenhouse designed for environmental monitoring in the process of agricultural production. The instrument can continuously monitor 4 environmental parameters, such as carbon dioxide gas concentration, light intensity and ambient temperature and humidity, and convert them into MODBUS-RTU standard RS485 signals and transmit them to associated equipment. The sensor can be equipped with off limits sound and light alarm equipment.

    1And CO2 sensors are adoptedDual channelDetection of carbon dioxide non dispersive infrared gas detection technology concentration, has high measurement accuracy, good repeatability, wide measuring range, long service life, no other background gases (CH4, H2S, SO2, N2, O2) effect etc..

    2The high performance single-chip microcomputer and high integration digital circuit are adopted in the design of the sensor. The structure is simple, the performance is reliable, and the debugging and maintenance are convenient.

    3The sensor can be continuously detectedCarbon dioxide, light intensity, temperature, humidityYou can also use the out of gauge alarm output function.

    4The sensor is designed with low power consumption and long distance.

    5The outer shell of the sensor is designed with high strength and strong shock resistance.

    Use note

    1.The built-in CO2 sensors are part of the deviceDual channelNon dispersive infrared carbon dioxide sensors require full ohmic heating to achieve good service conditions. We recommend that you preheat for at least 3 minutes.

    2.The product is used in the greenhouse, the mushroom house, the environment, the air quality control multi-function detection device. Carbon dioxide concentrationIlluminance, temperature, humidityFor detection of carbon dioxide gas sensitive components, the concentration range was 0~5000ppmThe illuminance is 0~65535LuxAnd the temperature is -40~+120CThe humidity is 0 ~ 100%RH.

    technical parameter

    Serial number

    parameter

    Technical index

    1

    Protection level

    IP63

    2

    Carbon dioxidemeasuring range

    0~ 5000 PPM

    3

    Carbon dioxidemeasurement accuracy

    + 100 PPM

    4

    Range of temperature measurement

    -40~+120C

    5

    Temperature measurement accuracy

    0.5 DEG C

    6

    Range of moisture measurement

    0~ 100%RH

    7

    Humidity measurement accuracy

    + 4.5%RH

    8

    Illuminancemeasuring range

    0~65535 lux (can be customized 0-20luxRange)

    9

    Illuminancemeasurement accuracy

    + 3%FS (25 DEG C)

    10

    output signal

    Mod bus RS485

    11

    baud rate

    9600

    12

    Power supply

    DC7-36V

    13

    Power waste

    < 4W

    14

    Out of gauge output

    Alarm or relay control (custom-made)

    15

    Working environment temperature

    -30C~ +85 degrees centigrade

    16

    Working environment humidity

    0~ 100%RH

    17

    size

    153*90*55mm

    Installation size