RS485 temperature and humidity transmitter SHT30 SHT31 MODBUS temperature and humidity sensor dew point temperature

RS485 temperature and humidity transmitter SHT30 SHT31 MODBUS temperature and humidity sensor dew point temperature

Price:   $40.32

  • Model: ic0A272
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)

Please Choose:

  • Khaki
  • orange
  • Maroon
  • Green Jade
  • Wheat
  • Red
  • WHITE
  • Grey
  • Blue
  • green
  • Black
  • Yellow
  • purple
  • Pink
  • Beige
(complete orders today,deliverd around 26/04/2025)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    SMD chip resistor 1% 0201 0402 0603 0805 1206 1210 1812 2010 2512 0R 0.01R 0.1R 1R 10R 100R 1K 10K 100K 1M 10M 100M 100PCSLOT
    $20.00
    100pcs 0201 Resistor 5% 0R ~10M 120W Chip SMD 0 1 10 100 150 220 330 ohm 1K 2.2K 4.7K 10K 100K 0R 1R 10R 100R 150R 220R 330R 1M
    $0.21
    60 Values x 20Pcs SMD 0603 Resistors Assorted Set 1200 Pcs 0ohm - 10M Ohm 110 Watt 1% High Precision Film Chip Resistance Kit
    $8.55
    100Pcs 0805 SMD 14W 0R ~ 10M chip resistor 5% 0.1R 0.28R 10R 100R 220R 330R 470R 1K 4.7K 10K 47K 100K 0 0.82 10 100 330 470 ohm
    $0.64
    • Details
    • Reviews
    • Tags
    • FAQ
    Condition:New
    Type:Logic ICs


    Voltage: 7-24VDC Sensor: SHT30/SHT31



    With display:



    O1CN01TXrAmW1o7ZRUg1Z99_!!105515178



    Without display:









    In the high temperature test, the temperature and humidity of the constant temperature and humidity experiment box (the figure below) are compared with the sensor readings (the figure above), and the results are consistent.






    Standard MODBUS communication format, 8-bit DIP switch on the board to set the communication address and baud rate, MODBUS function code 04 to read the data, readable: humidity value + temperature value + dew point temperature value 3 values.



    Example sending: (01)+(04)+(00 00)+(00 03)+(B0 0B)

    Sensor address + function code + register first address + number of read bytes + CRC16 check

    Return: (01)+(04)+(06)+(02 03)+(01 30)+(00 C0)+(24 D2)

    Sensor address + function code + number of returned bytes + humidity + temperature + dew point temperature + CRC16 check

    Humidity (0203) hexadecimal data converted to decimal is 515, the actual humidity is 51.5%;

    Temperature (0130) hexadecimal data is converted to decimal 304, the actual temperature is 30.4 degrees Celsius;



    The dew point temperature (00C0) hexadecimal data is converted to decimal 192, and the actual dew point temperature is 19.2 degrees Celsius;

    Modified to be compatible with 03 04 function code at the request of customers;