Sewage treatment plant level sensor liquid level monitoring sensor probe level water level switch
Sewage treatment plant level sensor liquid level monitoring sensor probe level water level switch
Sewage treatment plant level sensor liquid level monitoring sensor probe level water level switch
Sewage treatment plant level sensor liquid level monitoring sensor probe level water level switch

Sewage treatment plant level sensor liquid level monitoring sensor probe level water level switch

Price:   $9.55

  • Model: ic0A1518
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)

Please Choose:

  • 0-5V
  • 0-20mA
  • 4-20mA
  • 0-10V
  • 0-75mV
(complete orders today,deliverd around 25/04/2025)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    Freeshipping 6 level 7 level electromagnetic gun ABS pipe high voltage with display and Steel ball
    $149.09
    LCD 16x4 1604 Character LCD Display Module LCM Blue Blacklight 5V for Arduino
    $3.79
    XH-M164 NE5532 Stereo Pre-amp Preamplifier Tone Board Audio 4 Channels Amplifier Module 4CH CH Control Circuit Telephone Preamp
    $3.79
    100% New uP9026Q uP9025P QFN
    $8.88
    • Details
    • Reviews
    • Tags
    • FAQ
    Dissipation Power:W
    Model Number:XKC-Y25-T12V
    Operating Temperature:C
    Supply Voltage:V
    Type:Logic ICs
    Condition:New
    Application:0

    First, product overview

    Non contact type liquid level sensor (hereinafter referred to as the intelligent liquid level sensor) using advanced signal processing technology and high-speed signal processing chip, break through the influence of the wall thickness, the height of the liquid level in the sealed container real non contact detection. The liquid level sensor (probe) is installed in the upper and lower part of the outer wall of the tested container (high and low liquid level), and the non metal container does not need to open the hole, and the installation is simple and does not affect the production. The liquid level can be realized on the high pressure sealed container of toxic substances, acid and alkali and other liquids were detected. The liquid level sensor has no special requirements for the material of the liquid medium and the container, and can be widely used.

    Intelligent non-contact liquid level sensor is divided into four kinds of signal output interface, which are high and low level output interface, NPNOutput interface,PNP output interface,RS485Interface, respectively, corresponding to the four models:(please note that the customer to buy a good thank you!)

    High and low level output interface - type:XKC-Y25-T12V (default)

    NPNOutput interface model:XKC-Y25-NO (NPN)

    PNP output interface - model:XKC-Y25-NO (PNP)

    RS485Interface model:Y25-RS485 XKC-


    Two, product characteristics

    N non-contact liquid level sensor, suitable for non metal container without direct contact with the liquid, will not be affected by the corrosion of acid alkali and other corrosive liquids, no scale or other debris impact.

    N intelligent liquid level adjustment and level memory function, liquid level display mode, can realize multi point series connection; can support high and low level output,NPNOutput, PNP output,RS485Data signal output (type selection and manufacturers can be described).

    N detection accuracy and stability, can be detected boiling water level.

    N pure electronic circuit structure, non mechanical working mode, stable performance and durability.

    N high stability, high sensitivity, strong interference ability, not subject to external electromagnetic interference, for the power frequency interference and common mode interference to do special processing, in order to be compatible with all the5~24VThe power adapter

    N strong compatibility, through a variety of non-metallic materials, such as containers, such as plastic, glass, ceramics and other containers, sensing distance up to12mmAbove; liquid, powder, particulate matter can be detected.

    N open collector output, wide voltage range (5~24V), suitable for connecting all kinds of circuit and product application.

    Three, working principle

    The intelligent non-contact liquid level sensor is induction capacitor use of water to detect whether liquid exists, no liquid in proximity sensor, the sensor because of distributed capacitance, so the inductor to exist certain static capacitance, when the liquid level rises close to the sensor, the parasitic capacitance will be coupled to the static liquid the capacitance, the capacitance sensor value becomes large, the change of the capacitance signal input to the controlICSignal conversion, the variation of the capacitance will change into a signal, and then by a certain algorithm to detect and judge the change degree, when the change exceeds a certain threshold that the liquid level reaches the induction point.

    Four, product parameters

    entry name

    parameter

    Input voltageInVCC)

    5~24 V DC

    Current consumption

    5mA

    Output voltage (Gao Dianping)

    InVCC

    Output voltage (low level)

    0V

    Output current

    1~50mA

    response time

    500mS

    Working environment temperature

    0~100C

    Induction thickness (sensitivity) range

    0~20mm

    communication

    RS485

    humidity

    5%~100%

    Texture of material

    ABS

    Waterproof property

    IP67


    undefined


    undefined