Single high current discharge instrument 40A battery capacity detector measuring instrument electronic load instrument TEC12H
Single high current discharge instrument 40A battery capacity detector measuring instrument electronic load instrument TEC12H
Single high current discharge instrument 40A battery capacity detector measuring instrument electronic load instrument TEC12H
Single high current discharge instrument 40A battery capacity detector measuring instrument electronic load instrument TEC12H

Single high current discharge instrument 40A battery capacity detector measuring instrument electronic load instrument TEC12H

Price:   $61.21

  • Model: ic0A866
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)

Please Choose:

  • With bluetooth
  • Without bluetooth
  • With bluetooth
  • Without bluetooth
  • Without bluetooth
(complete orders today,deliverd around 24/04/2025)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    100% New IT8226E-192 IT8227E-256 IT8227E-192 IT8226E 192 IT8227E 256 QFN-128
    $11.88
    LilyPad LiPower Lithium Battery boost Power step up Battery Module 5V output
    $0.73
    100% New AM5200IAJ44HM BGA Chipset
    $19.40
    Raspberry Pi 3 CPU Fan Active Cooling Fan for Customized Acrylic Case Support raspberry pi model B Plus B+Raspbery Pi 2
    $0.73
    • Details
    • Reviews
    • Tags
    • FAQ
    Brand Name:icchipcn.com
    Condition:New
    Type:Logic ICs
    Model Number:TEC12H

    Brief description of the principle: TEC-12H battery discharge meter is also a battery capacity tester, which is designed for low-voltage single batteries, and the maximum discharge current is 40A. The instrument adopts the principle of closed-loop control, so that the discharge current reaches the set value and does not change with the voltage. The detector uses manganese copper resistors with low temperature drift for current sampling, and MOS tubes as current control devices, so that the controlled current can be within the error range of 0.5%. The MPU is used to control the entire circuit, including the display interface, adjustment buttons and timing. The timing of this tester is based on the product of current and time, which is used as the calculation of battery capacity.

    UI:

    ? Intuitive display: The tester uses two 4-digit digital tube displays, and the upper screen displays the measured voltage during operation. The lower screen can be switched to display capacity (AH), cut-off voltage (V), current (A), temperature (℃), and there are corresponding LED lights to indicate.

    ? Measured voltage: Displays the actual voltage of the battery under test or other power sources under test. Displayed units are volts.

    ? AH: Displays the capacity value. As the discharge process progresses, this value has been accumulated and stopped after the discharge is completed. The units shown are AH.

    ? Cut-off voltage: It is a parameter set by the user. When this voltage is reached, the detector will automatically stop discharging.

    ? Current: It is the discharge current of the detector.

    ? Temperature: It is the temperature of the heat sink of the detector, and the starting of the fan and the automatic control of the power are all based on this measurement temperature.

    Technical Features:

    ? It can be controlled by the control board, and it can be controlled by the RS485 bus without the control board.

    ? There are two options for the display screen: integrated in-line screen and external led screen. The external screen is more suitable for users to DIY.

    ? The maximum withstand voltage is 5V, and the maximum power is 175W.

    ? Maximum current: a single battery with a voltage above 2V can discharge up to 40A.

    ? It can work independently without the computer, and can also be controlled by the computer as the upper computer.

    ? There are 2 data interfaces: USB, RS485 (Modbus).

    ? Modbus (RTU) industrial bus, using RS485 interface, can realize the networking of up to 90 devices.

    ? Intelligent power limit, with over-temperature protection, anti-reverse protection function.

    ? With multiple protection functions, including: anti-reverse protection, over-temperature protection, maximum power limit, under-voltage protection.

    ? Power-off data storage function: If the power is off during the measurement process, the accumulated capacity can be automatically retained.

    ? Music alarm after the measurement, three music options: Beethoven Symphony No.9Are you sleepingKamata March, can also be set to mute.

    technical parameter:

    ? Power supply: 12Vdc (the actual required current is about 1.0A), and the power supply interface is 5.5/2.1mm.

    ? Current range: 1~40A.

    ? Current adjustment solution step size: the adjustment step size below 10A is 0.1A; the adjustment step size above 10A is 0.5A.

    ? Shutdown voltage adjustable range: 1.0V~5.0V. Adjustment step size 0.1V

    ? Maximum current error: 0.5%.

    ? Maximum voltage error: 0.2%+0.01V.

    ? Maximum timing error: 0.1%.

    ? Capacity detection maximum error: 0.6%.

    ? Weight: net weight 0.2kg;