Single-phase AC voltage isolation transmitter signal conversion module 0-380VAC to 0-10VDC card
Single-phase AC voltage isolation transmitter signal conversion module 0-380VAC to 0-10VDC card

Single-phase AC voltage isolation transmitter signal conversion module 0-380VAC to 0-10VDC card

Price:   $37.62

  • Model: ic0A1268
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)

Please Choose:

Option
(complete orders today,deliverd around 26/04/2025)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    Water leakage sensor, rail type immersion controller, relay switch output
    $23.78
    Beetle Leonardo USB ATMEGA32U4 Mini Development Board
    $5.60
    Making 0.15X60 shares high frequency transformer line wire wire stock litz USTC
    $21.16
    ADS1232 1232 24 bit ultra low noise to digital converter ADS1232IPWR
    $5.60
    • Details
    • Reviews
    • Tags
    • FAQ
    Condition:New
    Type:Logic ICs
    Model Number:KB-44


    1


    Main technical specifications
    AC voltage signal isolation transmitter
    The AC voltage signals of various equipment on the site are transmitted through isolation, and the DC current or voltage signals are output to the control system or other unit combination instruments. Signal isolation can effectively eliminate ground backflow, and solve industrial field interference and signal conversion transmission and matching problems.
    This is a one-in-one AC voltage signal input isolator. The isolator uses an independent DC power supply, and the power supply-input-output is isolated. Standard 35mmDIN rail card installation.
    Power supply
    Power supply voltage: 24VDC ± 10%
    Current consumption: <80mA (with 24VDC power supply)
    Power loss: <2W (when 24VDC power supply)
    Input
    Input current: 0 ~ 10VAC, or other specified voltage signal
    Voltage input impedance: 100K
    Output
    Output current: 4 ~ 20mA; other specified currents
    Output voltage: 1 ~ 5V; other specified voltages
    Allowable load of current output: ≤500Ω
    Voltage output load current: ≤5mA
    Output ripple: <20mV p-p
    (Note: the current output ripple is measured under the condition of 250Q resistance)
    Comprehensive main technical parameters
    Standard accuracy: ± 1% F.S
    Temperature drift: ± 0.015% / ℃
    Response time: <0.1s (10 ~ 90%)
    Settling time: ≤1s
    Influence of power supply change: <± 0.1% (allowable voltage range)
    Isolation withstand voltage: 2500VDC / min
    Insulation resistance:> 100MΩ
    Output ripple: ≤20mV / Vp_p
    Working environment temperature: -10 ~ 50 ℃
    Working environment humidity: ≤85RH%
    Storage environment temperature: -30 ~ 60 ℃
    Dimensions: width 16.6 × height 105 × depth 65 (mm)
    Material: Flame retardant ABS + PC
    Dust-proof design: Yes

    2
    3
    Application, terminal wiring diagram
    Cooperate with other unit instrumentation applications.
    Suitable for connected field devices: two-wire transmitter.
    Terminal wiring: single-core or multi-core cable with a cross-sectional area of 0.2 to 1.5 mm2, which is screwed tightly.
    4