STY-380D75G three-phase fully isolated AC voltage regulator module TB-3 4-20MA control
STY-380D75G three-phase fully isolated AC voltage regulator module TB-3 4-20MA control
STY-380D75G three-phase fully isolated AC voltage regulator module TB-3 4-20MA control

STY-380D75G three-phase fully isolated AC voltage regulator module TB-3 4-20MA control

Price:   $128.20

  • Model: ic0A4484
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)
(complete orders today,deliverd around 25/04/2025)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    (5piece)100% New NCP81226 NCP81226MNTXG QFN-52
    $8.40
    100% New CD3215C00ZQZR CD3215C00 CD3215COO CD3215 BGA
    $8.20
    5PCS G4PC40KD IRG4PC40KD TO-247
    $7.19
    DC 12-16V High Voltage Arc Ignition Mode for Ignition Cigarette Lighter
    $9.63
    • Details
    • Reviews
    • Tags
    • FAQ
    Condition:New
    Type:Logic ICs
    Model Number:STY-380D75G

    Model: STY-380D75G with TB-3 4-20MA control


    Three-phase AC voltage regulator module STY-380D75E / STY-380D75F / STY-380D75G / STY-380D75H


    The last digit of the model is the input control signal type, E means 0-5V; F means 0-10V; G means 4-20mA; H means 1-5V.


    The fully isolated three-phase AC voltage regulating module (hereinafter referred to as the three-phase voltage regulating module) integrates three-phase electrical phase detection, phase shifting circuit, trigger circuit and three sets of anti-parallel one-way thyristors. With the support of the phase synchronous transformer module (model TB-3) (the synchronous transformer is also used to provide the internal working power supply of the three-phase voltage regulating module), it can automatically control or The external potentiometer is manually controlled to achieve stepless adjustment of the three-phase load voltage from tens of V to the full voltage of the grid by changing the conduction angle of the thyristor.


    The model of the three-phase voltage regulator module is STY-380Dccc, where STY represents the three-phase voltage regulator module, 380 represents the use on the 380VAC three-phase power grid, and the box behind D represents the current level (a set of anti-parallel unidirectional thyristors). current level). The last digit of the model is the input control signal type, E means 0-5V; F means 0-10V; G means 4-20mA; H means 1-5V.


    Model list



    Note: The last digit of the model is the input control signal type, E means 0-5V; F means 0-10V; G means 4-20mA; H means 1-5V.


    Size:104*74*32mm

    Performance parameter:

    E serial

    F?serial

    G?serial

    H?serial

    Input range

    0~5V

    0~10V

    4~20mA

    1~5V

    Input resistance

    >30KΩ

    >30KΩ

    250Ω

    >30KΩ

    Valid input range

    0.75~4.75V

    1.5~9.5V

    5~19mA

    1.25~4.75V

    Phase shift angle range

    150°~0°

    150°~0°

    150°~0°

    150°~0°



    Application:

    12 is the output, the corresponding random solid-state relay output, the voltage level is 380VAC, can be used on the grid less than 420Vac. According to the different internal controllable silicon of the module, it is also divided into common type, enhanced type and half-wave type. The half-wave type is a one-way thyristor as an output contact, which only regulates the positive half cycle of the AC voltage (the anode of the unidirectional thyristor of the module is connected to the 1st end, and the cathode is connected to the 2nd end).34 is the module's internal synchronous transformer primary, divided into 220VAC and 380VAC two specifications: 220VAC module allows the use of the grid in the 165-240VAC range, 380VAC module allows the use of the grid on the 285-420VAC, 34 not the same name .COM is the internal ground, CON is the control end, and the +5V end is internally generated, and only the power supply unit is used for manual control. The strong part of 1234 and the weak part of +5V, CON, and COM are fully isolated.

    E serial

    F serial

    G serial

    H serial

    Input range

    0~5V

    0~10V

    4~20mA

    1~5V

    Input resistance

    >30KΩ

    >30KΩ

    250Ω

    >30KΩ

    Valid input range

    0.75~4.75V

    1.5~9.5V

    5~19mA

    1.25~4.75V

    Phase shift angle range

    150°~0°

    150°~0°

    150°~0°

    150°~0°

    Selection guide:

    Half wave type

    For electric shock airport

    Oridinary

    Low current module or dv/dt requirements for lower occasions

    Normal type

    High current module or dv/dt requires higher occasions

    220V

    220V loop load

    380V

    380V loop load (ie, using two live wires to load)

    Current capacity selection

    ①?For resistive load, the current rating of the SSR should be greater than or equal to 2 times the rated current of the load.

    ②When the load is an AC motor, the current rating of the SSR must be greater than or equal to 6-7 times the rated motor current.

    ③When the AC electromagnet, intermediate relay line protection, and inductor coil are loaded, the current rating of the SSR should be greater than or equal to 4 times the rated current of the load.

    ④For power compensation capacitors, the current rating of the SSR must be greater than 5 times the rated current of the load.

    ⑤The transformer is required to be greater than or equal to 5 times the primary rated current of the transformer. For special inductive and capacitive loads, the current margin of the SSR must be amplified according to actual experience.


    Precautions:

    1. If the voltage applied to the load by?①②?is inconsistent with the voltage of?③④, please declare the voltage of the two, our company can customize for the user, but the phase must be the same, and 34 must be 220VAC or 380VAC, 50HZ Voltage level. There are no polarity in?①②?or?③④?rooms. For example, a rated voltage of a load is 36VAC (220V power grid is stepped down by a transformer). If a single-phase voltage regulator module of 75A is selected, the module of model TY-H36D75P-220 can be customized to our company,?①②?of which are connected in series with the load. Received 36V grid,?③④?feet connected to 220V grid.2. CON must be positive for COM. If the polarity is opposite, the output is out of control (fully open or fully closed). When the control terminal CON changes from 0-5V, the voltage on the AC load is adjustable from 0 volts to the maximum value (for resistive loads). Where CON is in the fully closed region at 0-0.75V, the output of the module is reliably turned off; CON is adjustable in the range of 0.75V-4.75V, that is, the conduction angle α is from 150 as the control voltage increases. The linearity decreases from ° to 0°, and the voltage on the AC load increases from tens of volts to the maximum value; when CON is about 4.75V-5V, it is the fully open region, and the voltage on the AC load is the maximum value.3. The input impedance of the E, F, and H series CON to COM is greater than 30KΩ, and the input impedance of the G series CON to COM is 250Ω. The +5V voltage signal is only available to the manual potentiometer. It is not used for it. The potentiometer used is between 2-10KΩ.4. The speed regulation of single-phase AC asynchronous motor should generally adopt frequency converter. Only soft characteristic load such as fan and pump motor, or torque motor can be adjusted by voltage regulation.5. Three single-phase voltage regulator modules cannot be used to regulate three-phase loads on a three-phase power grid (see three-phase voltage regulation).6. The insulation voltage between the weak current part, the strong electric part and the module bottom plate is greater than 2000VAC.7. The heat output of the whole module is calculated by the actual current amperage of the load by 1.5 watts/ampere. The radiator can be selected with E-40, F-70, F-100 and G series.8. Please refer to the single-phase AC solid state relay for the selection and protection of the current level.9. If the load has high linearity and voltage regulation requirements, please increase the voltage negative feedback module.