Temperature humidity ammonia gas hydrogen sulfide 4-in-1 sensor network transmitter detector online monitoring RJ45 Modbus TCP
Temperature humidity ammonia gas hydrogen sulfide 4-in-1 sensor network transmitter detector online monitoring RJ45 Modbus TCP
Temperature humidity ammonia gas hydrogen sulfide 4-in-1 sensor network transmitter detector online monitoring RJ45 Modbus TCP

Temperature humidity ammonia gas hydrogen sulfide 4-in-1 sensor network transmitter detector online monitoring RJ45 Modbus TCP

Price:   $244.97

  • Model: ic0A4723
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)
(complete orders today,deliverd around 25/04/2025)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    1pcs USB mini discharge load resistor 2A1A With switch 1A Green led, 2A Red led
    $0.74
    Triple Shield For WeMos D1 Mini Dua Sided Perf Board For Arduino Compatible
    $0.74
    20CM SMA Connector Cable Female to uFLu.FLIPXIPEX RF Or NO Connector Coax Adapter Assembly RG178 Pigtail Cable 1.13mm
    $0.74
    RGB pickup level light quasi glow tube clock rhythm light gift ornament WalnutBeech Base
    $112.98
    • Details
    • Reviews
    • Tags
    • FAQ
    Condition:New
    Type:Logic ICs

    Please note need RS485 or RJ45 input,when order.


    Product specification selection :

    A: High precisionB: High precision + indicatorC: High precision + 1 channel alarmD: High precision + indicator light +1 channelalarmE: High precision + LCD screenF: High precision + LCD screen +1 channelalarm

    First, product introduction

    Public toilets are urban public service infrastructure, and public toilets are safe and clean and directly affect the comfort of the city. As a world power, the toilet revolution has set off a national upsurge. The first-tier cities in the north and the north have successively proposed smart public toilets, and the smart public toilets are the direction of the toilet revolutionary road.This product is officially developed in this context based on data transmission technology of IoT technology, accurate measurement of high-precision sensors, and rapid sensing of changes in environmental parameters. According to the needs of different customers, different types and quantities of sensors, different display modes, alarm modes, communication methods, etc. can be selected. It can also display data to computers, touch screens, LED screens, cloud platforms, etc. as needed.This product has multiple protections such as lightning protection, anti-reverse connection, over-voltage, over-current and under-voltage. The product is fully interchangeable and is used to accurately measure the ambient temperature, ambient humidity, ammonia concentration, hydrogen sulfide concentration and other values. This product is output as a slave via a waterproof Ethernet RJ45 interface. The software is developed in full compliance with the standard MODBUS RTU/TCP/TCP communication protocol. Can be well compatible with WINCC, Kingview, Force Control, Kunlun Tongzhou, touch screen, PLC, cloud platform and other PC configuration software and hardware, as well as third-party software developed according to the standard MODBUS RTU/TCP/TCP protocol. Or hardware. And optional LCD screen display measurement data, after the limit of the buzzer sound alarm prompt, after the limit of the alarm relay drive alarm device action and other functions. This transmitter can be easily connected to the network equipment in the field for easy integration.Can be widely used in: intelligent public toilets, landfills, basement environmental monitoring, environmental monitoring of waste recycling plants, and other occasions requiring ambient temperature and humidity, odor, odor.In addition, products of different functions and different applications can be customized according to the technical requirements of the manufacturer.

    Second, technical parameters

    Air temperature and humidity sensorAir temperature measurement range: -40~80°CAir dew point temperature range: -40~80°CAir temperature measurement accuracy: ±0.3 °CAir temperature resolution: 0.1 °CAir temperature drift: <±0.04°C/yearAir humidity measurement range: 0~100RH%Air humidity measurement accuracy: ±2RH%@25°C (20%RH to 80%RH)Air humidity resolution: 0.1% RHAir humidity hysteresis: ±1% RHAir humidity drift: <±0.5%RH/yearWorking environment: -20~60°C, 5~95% RH

    Ammonia Sensor & Hydrogen Sulfide Sensor

    Ammonia Sensor:

    Project|parameterDetection gas|Ammonia gas (NH3)Range|0~50ppmMaximum measurement limit 200ppmSensitivity|(0.10±0.05) wA/ppmResolution|0.5ppmResponse time (To)|≤90sBias |OmVLoad resistance (recommended)|10QRepeatability|<10? Out of valueStability (/month)|<10%Output linearity | linear|Zero drift (-20°C~40°C)|-3~10ppmTemperature range | -20 ° C ~ 50 ° CHumidity range|15%-90%Rh, no condensationPressure range|standard atmospheric pressure ±10%

    Hydrogen Sulfide Sensor:

    Project|parameterDetection gas|hydrogen sulfide (H2S)Range 0~100ppmMaximum measurement limit 500ppmSensitivity (0.8±0.15) wA/ppmResolution|0.1ppmResponse time (Ts0)|<30SBias omVLoad resistance (recommended) 109Repeatability|<2% output valueStability (/month)|<2%Output linearity | linearZero drift (-20 ° C ~ 40 ° C) | ≤ 0.2ppmTemperature range 20 ° C ~ 50 ° CHumidity range|15%-90%RHPressure range|standard atmospheric pressure ±10%Supply voltage: 7~26VDC, in addition to 5V or other voltage specifications.Maximum power consumption: 500mA@12V with LCD (0802)Display mode: LCD0802 LCD screenLCD screen specifications: LCD0802 8 characters * 2 linesCommunication interface: RS485/Ethernet RJ45 interfaceCommunication protocol: MODBUS RTU/TCPCommunication rate: Software settings, 2400, 4800, 9600, 19200, 38400, 115200, etc. Default 9600bpsData format: default 8N1 (1 bit start bit, 8 data bits, 1 stop bit, no parity)Communication mode: The transmitter acts as a MODBUS RTU/TCP slave station, and the master station (touch screen, PLC, host computer, etc.) uses the master-slave polling method to query the real-time data of the transmitter.Device address: 1~253, software settings.Number of devices: theoretically up to 128 transmitters on the same bus, the actual application takes up 1/2~2/3Transmission distance: 1000 meters (RS485 communication dedicated cable)This product has been treated with three anti-prevention treatments before leaving the factory to ensure long-term use in high temperature, high humidity, high dust and corrosive gas environment.Installation method: wall-mountedProduct size: 125mm*100mm*52mm

    Third, the method of use

    Hardware parts:First plug the network cable into the waterproof Ethernet interface of the product, and connect the other end to the computer or router, hub, switch, etc., then connect your own switching power supply or the power adapter of the product to the power cable, or directly connect the power adapter to the DC. Plug the plug into the reserved power hole of the product.

    Software parts:

    According to your own system, choose to install 32-bit or 64-bit software. Generally, you only need to install modbus poll software. The following takes the WIN10 64-bit system as an example.Click: I accept the terms of the license Agreement ---> Next ---> Next ---> Install ---> Next ---> Cancel the check box before Show Readme - ---> FinishAfter the above steps, the software installation is complete.




    Power on the device. After a few seconds of product initialization, open the test file provided by the company, you can see the data collected by the transmitter, as shown below.
    Modify the alarm value upper limit, lower limit, transmitter address, baud rate, check digit and other parameter methods to modify the transmitter address as an example1 Mouse directly double-click the desired transmitter address value, ie 1, the following interface pops up:
    2 Modify the value behind 1 to the actual required value, the range 1~253, 254 is the universal query address, address 254, only suitable for the case where the bus has only one device. Here we set the value of 1 to 3, and then click the Send button, the address of the current device, you can change to 3, the device does not need to power off, the new value automatically takes effect.
    In order to better understand and learn the MODBUS RTU/TCP protocol, click on the menu bar Display--->Communication, you will see the instructions from the computer to get the data and the data returned by the transmitter; TX is the command issued by the computer. RX is the data returned by the transmitter

    Six, matters needing attention

    1. The transmitter is equipped with no test power supply and RS485 converter. If necessary, please contact the customer to purchase or purchase it yourself!2. The power supply voltage and output current used must meet the requirements, otherwise the product may be damaged or may not work properly.3. When connecting the transmitter cable, be careful not to connect it incorrectly, otherwise it may burn internal components or not work properly.4. Please use RS485 special cable as much as possible to improve transmission distance and stability.5. The transmitter station address setting must not be duplicated with other slave addresses.6. The transmitter has built-in 120Ω termination resistor. When the transmitter is at the end of the 485 bus, please close the S3 shorting sleeve.7, the transmitter slave station no more than 31, otherwise need to add RS485 bus bridge (relay), and the main station MODBUS RTU / TCP protocol, baud rate and other data formats must be consistent.8. The default communication baud rate is 9600bps and 8N1 data format when the product leaves the factory. If the user needs to modify the baud rate or data format, we provide the program software to modify it.