Brand Name:icchipcn.com
Condition:New
Type:Logic ICs
?Please note what you require when order:
? 8?Types of thermocouples (J,K, T,E, R,S,B,N,none)?
4?types?Thermal resistance (PT100,PT1000,CU50,CU100,none)
2?types?Current input (+20mA,4~20mA,none)
2?types?Voltage input (±1V,±5V/10V,none)
MB8ARTEightThe high precision mixed signal acquisition module can collect analog data.+20mA,4-20mA,+15mV,+100mV,+1V)EightKind of thermocouple(J/K/T/E/R/S/B/N),2Platinum resistance (PT100,PT1000,CU50,CU100Many other signals, and can be combined with each input channel signal type.The collected analog signal data is isolated.RS485Interface output; module adoptionModbus-RTUCommunication can be adapted toPLC,DCSAnd various configuration software.
Signal input, CPU, power input andRS485 communication electrical signals are isolated from each other, effectively suppressing all kinds of serial mode and common mode interference, ensuring the accuracy of data, but also ensuring the reliable work of the module.
MB8ARTThe module is mainly used for temperature acquisition and application of various analog input signal types. It can be widely used in iron and steel smelting, metal heat treatment, chemical industry, metallurgy, glass processing, injection temperature control, tobacco, medicine, automation equipment and so on.
- Characteristic
8Road mixed signal input (thermocouple, platinum resistance and analog).The input signal types of channels can be set according to their needs..
The thermocouple, thermal resistance andFour-20mA input have the function of detection and break detection, which is convenient for on-site debugging and maintenance.
Full differential input, and each channel is isolated from each other.
High precision signal acquisition: high precisionTwo4 bit AD and voltage reference, voltage reference temperature coefficient 10PPM/ centigrade.
Independent high precision cold end compensation with accuracy of + 0.5 C.
Safety: signal collection, signal output, power supply, RS485 communication and electrical signals are isolated from each other.
Adopting the standard Modbus-RTU protocol, the RS485 communication signal output interface adopts over voltage and over current double protection.
The input signal type and communication format can be set by software.
Power input polarity protection and overvoltage protection.
Technical indicators
project | parameter |
AI Signal input | OneInput channel: 8 way differential input.Inter channel isolation TwoIsolation voltage between channels:Three00V ThreeInput signal type: 8?Types of thermocouples (J,K, T,E, R,S,B,N) 4?types?Thermal resistance (PT100,PT1000,CU50,CU100) 2?types?Current input (+20mA,4~20mA) 2?types?Voltage input (+15mV,+100mV,+1V) FourSetting mode: through software setting, current input also needs jumpers on short circuit board. FiveScan cycle: 8 channels are collected every 500mS. SixADResolution: 24 bits. SevenSignal acquisition circuit and power input isolation voltage protection: 1000V |
RS485 Communication output | OneCommunication protocol: Standard MODBUS-RTU. TwoCommunication distance: 9600bps 1200 meters. ThreeCommunication medium: ordinary twisted pair, greater than or equal to 0.5mm2. FourInterface type: isolated RS485 communication, and the output interface adopts over voltage and over current double protection. FiveBaud rate: 1200BPS, 2400bps, 4800bps, 9600bps, 19200bps, 38400bps 57600bps, 115200bps. 6. Check bit: no check, parity check, odd check. SevenData bits and stop bits: 8 bit data bits and 1 bit stop bits, these two parameters are not adjustable. EightPower input and RS485 circuit isolation voltage protection: 1000V. NineSetting mode: module address, baud rate, parity bit can be set by software. |
Module size | OneSingle module size: L104mm * H72mm * H26mm TwoTerminal and guide box dimensions: L124mm * W72mm * H45mm |
Installation method | Standard 35mm DIN guide rail installation |
work environment | OneTemperature: -10 ~ +55 C TwoHumidity: 35 to 85% (no condensation) |
Working power supply | 1Power supply voltage: 10V to 30V wide range of power supply, polarity protection with power supply 2Power consumption: less than 2W |
measurement accuracy | Input type | measuring range | Display resolution | accuracy |
Thermocouple | J(-200 ~ 1200 C) | 0.1C | 0.4 degrees centigrade |
K(-200 ~ 1370 C) |
T(-200 ~ 400 C) |
E(-200 ~ 950 C) |
R(-20 ~ 1750 C) | 0.6 degrees centigrade |
S(-20 ~ 1750 C) |
B(600~1800 degrees Celsius) |
N(-250 ~ 1300 C) | 0.4 degrees centigrade |
Cold end compensation | -2080 degrees centigrade | 0.1Centigrade | <1 degrees centigrade |
Thermal resistance | PT100(-200 ~ 850 C) | 0.1Centigrade | + 0.1FS |
PT100(-200 ~ 850 C) | 0.1Centigrade | + 0.1FS |
CU50(-50 ~ 150 C) | 0.1Centigrade | + 0.1FS |
CU100(-50 to 150 degrees Celsius) | 0.1Centigrade | + 0.1FS |
Current input | + 20mA and 4 ~ 20mA | 0.001mA | + 0.1FS |
Voltage input | + 15mV | 0.001mV | + 0.1FS |
+ 100mV | 0.01mV | + 0.1FS |
+ 1V | 0.0001V | + 0.1FS |
- Product appearance, terminal definition and status indication
Product appearance

Terminal definition
Q1: What Is Your Product Warranty?
A: We Guarantee Our Product Is Fit For Its Normal User Purposes And Is Free From Defects In Materials Or Workmanship.
Q2: What Is Your Company Policy On Defective Goods?
A: Our Company Keep Items Quality For A Long Time. If There Are Any Defective Goods Due To
Production Defects Or Transportation Problem, Please Contact Us. Our Customer Service Team Will Provide Immediate Response To
Complaints. We Will Try Our Best To Give You A Good Resolve Way.
Q3: What Is Your MOQ (minimum Order Quantity)?
A: Generally Our Moq Is No Limited. Please Have More Discussion With Us If Your Combination Of Models Is Complicated.
Q4:how About Getting Samples From You?
A: We Will Send You The Samples After We Receive The Payment For Samples. The Buyer Shall Afford The Shipping Cost. Please Have A
Confirm With Us Which Shipping Way Do You Want.
Q5:about The Shipment: What Type Of Shipment Will You Use?
A: We Usually Ship The Products By Express(delivery It To Your Door) Or By Air Freight To Your Nearest Airport, Shipping Days:3-7
Working Days Depend On Destination;if The Order Quantity Is Large, We May Ship By Sea Container And The Best Ship Way Is By Sea,
Shipping Days: Over 20 Working Days Depend On Destination Port.
Q6:what Packing Do You Use?
A: Neutral Package With Airbag Or Customized Package.
Q7:how Much Are The Shipping Cost?
A:shipping Cost Is Charged By The Package's Weight And Related To The Shipping Methods You Choose And Your Destination.
Q8:how To Order?
Step1.Click (Add to Cart) Buy Directly On The Product Page, Or Add To Shopping Cart And Settle Together, Pay With Paypal,
Need your information, such as full name,country, city, detail address, post code, tax number ...
Step2. We Will Delivery by EMS POST, FedEx or DHL Within
3-5 Working Days After Payment Confirmed.
Setp3. Confirm Us Receipt of Products.