Three phase fully isolated AC phase shift voltage regulator module 35A power regulator LSA-TH3P35Y
Three phase fully isolated AC phase shift voltage regulator module 35A power regulator LSA-TH3P35Y
Three phase fully isolated AC phase shift voltage regulator module 35A power regulator LSA-TH3P35Y
Three phase fully isolated AC phase shift voltage regulator module 35A power regulator LSA-TH3P35Y

Three phase fully isolated AC phase shift voltage regulator module 35A power regulator LSA-TH3P35Y

Price:   $72.35

  • Model: ic0A895
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)

Please Choose:

  • 5SNA1200G450300
  • 5SNA1200G450350
  • 5SNA1500E330300
  • 5SNA1500E330305
  • 5SNA1200G330300
(complete orders today,deliverd around 09/07/2024)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    Jacobs ladder model arc rising spark high voltage discharge student experimental principle explanation
    $67.28
    DC-DC 150W 300W300W 20A 400W Boost Constant Current Module Non-isolated Step-up Board LED Driver Converter Power Supply Board
    $3.78
    1Pcs RT18A01 RS485 Transceiver Wireless Repeater 485 Master-slave control 433M 868M FSK Uhf Module
    $10.23
    USB Mini Humidifier DIY Kits Mist Maker and Driver Circuit Board Fogger Atomization Film Atomizer Sheet Mini Oscillating Double
    $1.87
    • Details
    • Reviews
    • Tags
    • FAQ
    Condition:New
    Type:Logic ICs
    Dissipation Power:35A
    Model Number:LSA-TH3P35Y
    Supply Voltage:0-10V
    contact form:Conversion type


    Than the use of materials, than the quality of the pressure adjustment module is the best material on Taobao, the design is the most perfect.



    What is the reason?



    1 no external +12V DC power supply.Some products need to provide you with +12V power supply, and there are power precision requirements for you to use caused great inconvenience and annoyance. This product does not require the user to provide DC power supply.



    2 no external synchronous transformer (or other trigger module) is required for this product.Due to the reasonable design, the use of space for you to use, but also to simplify the installation and wiring. At the same time, less wiring also reduces the possibility of poor contact.



    3 control methods for the full COMpatibility.You can use potentiometer control, you can also use a variety of automatic signal control (such asFour-20mA, 0-5VDC, 0-10VDC, etc.), a module can be COMpetent for a variety of applications, control handy. This allows you to select a simple, easy to prepare, to avoid the loss caused by the wrong type selection.



    4 control accuracy is very high.Users usually ignore the observed accuracy of this parameter. Extremely narrow range of products, some adjustment, such as 4-20mA control, the actual range only 6-13mA (stunning); some even unable to output 0 or unable to output the maximum. Such immature products are worth pondering.



    FiveUsing imported ST high power silicon controlled silicon as the core component of the module.High quality products are not only the pursuit of the user, but also our reputation and life.



    6 this series has a close loop negative feedback function, to meet the needs of different levels of customer.Some customers need to have a negative feedback function of the voltage regulator module for very high requirements of industrial applications, for no suitable products and worry. Division I for this part of the high requirements of the customer specially developed thisSelf voltage negative feedback three-phase voltage regulator module, no external power supply, trigger module, the use of very convenient.Welcome users before and after sale to do technical exchanges with us!












    RoncoLSA-A series of integrated three phase voltage regulator module is designed with imported large scale integrated circuit,RCThe resistance capacitance absorbing circuit and the power circuit are equal to one, which can be adjusted automatically or manually to change the voltage on the load to adjust the three-phase output power. Under the control action of the input, the three phase can change the strong trigger pulse signal to control the internal controllable silicon and realize the three-phase load voltage.0VTo the full voltage of the power grid can be adjusted continuously.


















    Examples of product application:






    Heating:Electric furnace, injection molding equipment, thermoplastic molding, textile equipment, infrared heating, power supply distribution system, drying



    Electric machinery:Fan motor, water pump motor, injection molding machine, torque motor



    Lighting:Public lighting, industrial lighting, stage lighting



    Other:Transformer, inductance coil, electric welding, electroplating



    IMG_20180504_131308















    Product features:



    1, without external synchronous transformer, also need not external input +12V DC power supply.



    2, the input control end of the high voltage and main circuit between full isolation design, insulation medium pressure greater than 2000 VAC, the UL safety electronic components.



    3,The high power thyristor and low heat resistance copper ceramic bonding (DCB) are used in the low volume, stable performance and high reliability.



    4Comprehensive support for 4-20mA, 0-5Vdc, 0-10Vdc, 1-5Vdc, 0-10mA and other input automatic control mode, also can be used manually control. The input adjustment range is wide, the output regulation accuracy is high, the three phase symmetry is good, the anti-interference ability is strong.5Linear compensation function, the output characteristic curve is linear.



    6Smaller harmonic interference, the product has a built-in SCR protection circuit.



    7, product can adapt to the transformer inductive load or electric heating resistive load, the load delta shaped or Y-shaped connection can, Y-connection balanced three-phase load center do not have access to the N line.



    8Products are also suitable for small power three-phase torque motor speed, and the fan, pump, etc., can also be applied to the slow start of the AC motor.



    9There is a power indication.green light(input signal indicator.Red lightStatus indication ()Yellow light) three color indication.



    10,Products suitable for three-phase four wire circuit, AC 380V + 10%, frequency: 50Hz. Automatic identification of phase sequence, into line circuit R, S, T phase requirements. If the user needs to be used in other voltage, or zero line, can be customized to my company.






    The product has three color lights, the problem can be judged by the lights:



    green lightPower indicator light. If L and N (220V power) no electricity, the green light is not bright, this time should check whether the L and N are in good contact. Please pay special attention to N and L can not be connected to the anti.



    Red lightInput signal indicator. If the input signal is the smallest (or has not yet access control signal), the red light is not bright. The red light intensity represents the intensity of the input signal. The greater the control signal, the more bright red light, the voltage output value of the module is also greater.



    Yellow lightStatus indicator light. When the module output is zero, the yellow light is bright, and the yellow light is not bright when the output voltage is output.



    Yellow lightLight conditions have the following:



    1. Missed any control mode, the module output voltage is zero.



    Two There is a control signal, but the control signal is very small, at this time the module output voltage is zero.



    ThreeOver temperature alarm. If the temperature of the module itself has reached 75C, the module will automatically stop working. At this point should be promptly cut off the power supply, to strengthen the cooling and then continue to work.









    Product load output current levels and models are as follows:



    HTB1c9LTLXXXXXctXpXXq6xXFXXXr















    long105 xwide75 xhigh36mm




























    Full compatible input control mode



    Unique fully compatible input control mode to enable the product to0-5Vdc,0-10Vdc,4-20mA,1-5Vdc,0-10mAAnd other automatic methods are able to adapt, do not need special custom, can also be used to manually control the potentiometer.




    • 4-20mAcontrol mode:According to the icon, can accept the temperature control table, such as the 4-20mA analog signal, the module's internal 4-20mA terminal relative to the input impedance of COM is 250. When this method is used, the +5V end and the CONT end are suspended.


    • Manual control mode of potentiometer:According to the icon, the middle end of the potentiometer is connected to the module CONT end, and the other ends of the potentiometer are respectively connected to the module COM end and the +5V end. When the control side CONT from the 0-5Vdc change, the AC load voltage from 0 V to the maximum linear adjustable, CONT voltage is higher, the greater the module output. 5V voltage by the module itself produced, without the need for external supply, with only hand control potentiometer with and without it, the selected resistance value of the potentiometer 2-10K Omega between. In this way, the '4-20mA' end is suspended.


    • 0-5Vdccontrol mode:According to the icon, can accept the MCU and other 0-5Vdc analog signal, the input control of the positive pole connected to the CONT terminal, negative electrode connected to the COM terminal, the module internal CONT end of the input impedance is greater than 30K COM. When this method is used, the +5V and the '4-20mA' end is suspended.


    • 0-10Vdccontrol modeAccording to the icon, can accept 0-10Vdc and other analog signals, the module's internal 0-10Vdc end of the input impedance is greater than 15K COM. When using this method of "4-20mA" end suspended, +5V terminal and COM terminal short circuit, 0-10Vdc control signal from the 0-5Vdc control terminal via entering.


    • 0-10mAcontrol modeAccording to the icon, this method should be used in the module CONT and COM between the end of a 500 ohm, 1/2W resistance, when the input 0mA corresponds to the CONT 0Vdc, when the input 10mA corresponding to the CONT 5Vdc.



    Matters needing attention in control terminal:



    1, the function of the end of the relativecomEnd must be positive,comThe end of the negative electrode, such as the polarity of the module is connected to the main circuit output terminal may be out of control.






    Module 2, each side of the control characteristics are positive characteristic, control, and the higher the voltage, the output voltage of the module of high voltage main loop.






    3, at a time appropriate to use an input control, if more than two ways to use the same time, it is generally a strong input signal a major role. To use both manual and automatic, such as automatic4-20mAHand in hand0-5VFunction switch can be performed by a double throw switch.






    4If silicon controlled silicon in the module can be long time output large current (i.e. main circuit input voltage is very high, the output voltage is low), which may lead to serious heating of the module.



    5,Module has linear compensation function, input and output characteristic curve:






    The main circuit power output application circuit wiring



    ?



    1,Installation: wall mounted vertical installation, power supply for progress under the. When connecting the copper terminals to remove debris, tighten the screws, otherwise it will cause the terminal to heat and cause damage.






    2,Into the line of three-phase AC circuitR,S,TThe phase conductor thickness requirements, according to the actual use of the current selection.






    3,NThe wire is only used for internal control of the module.1Square fine wire,NBetween the line and the input control end for the isolation of insulation design.






    4,U,V,WOutput terminal can be connected380VacA shape or load220VacYShape load (no need to connectNLine).






    5,Over current protection: in the use of the process if the flow phenomenon, should first check the load with no short circuit, etc.. Can be in the moduleIncoming lineR,S,TEnd beforeInstall fast fuse, the specification can be according to the actual load current1.5Times matching.






    6,Model for LSA-TH3P35Y and above products should be installed radiator, there is enough heat radiation space between the cabinet and the other devices. When installing the heat should be evenly in the thermal grease product on the floor, the floor with good heat radiator.Model for LSA-TH3P70Y and above products should be installed 220V AC fan forced cooling.The heat dissipation effect is not only concerned with the actual use of the size of the current and the heat sink and ambient temperature (summer and winter), ventilation conditions (natural cooling, forced cooling air volume) and installation density and other factors related to. We can add the appropriate radiator and fan according to the actual load of the load.






    7,Module used in three-phase four wire circuit wiring diagram:












    8,ModularAutomatic identification of sequence,Incoming line of a circuitR,S,TThe phase requirements. Three phase output



    Voltage symmetry is good, normalThree phase output error is not more than 5V, if the deviation is a little



    Obviously, please check the three-phase lineR,S,TWhether the voltage is consistent,Whether the balance of three-phase load.






    1. Resistance load, the choice of voltage regulator module of the current level should be greater than or equal to3Load current rating.



    2 When the load is AC motor, the current level of the voltage regulator module must be greater than or equal to5-6Times the rated current of the motor.



    3 meetThe current rating of the voltage regulator module should be greater than or equal to the load of the electromagnet and the inductance coil.4Load current rating.



    4. meetWhen the capacitive load is, the current level of the voltage regulator module must be greater than5Load current rating.



    5. Transformer is greater than or equal to5Transformer primary rated current, special inductive, capacitive load should be based on the actual situation still need to enlarge the voltage regulator module of the current margin.



    High current voltage regulator module with optional optional radiator, radiator specific specifications please contact the shopkeeper.