Three-phase electric energy acquisition module, electric energy acquisition module, three-phase electric parameters acquisition
Three-phase electric energy acquisition module, electric energy acquisition module, three-phase electric parameters acquisition
Three-phase electric energy acquisition module, electric energy acquisition module, three-phase electric parameters acquisition

Three-phase electric energy acquisition module, electric energy acquisition module, three-phase electric parameters acquisition

Price:   $83.54

  • Model: ic0A186
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)
(complete orders today,deliverd around 26/04/2025)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    TEC1-03108 TEC1-03108T200 20*20 3V8A refrigeration temperature of 200 degrees large temperature difference of cooling plate
    $13.85
    6 way PLC amplifier board isolation board 2 NPN package into the PNP out of the band module
    $12.23
    1.8 inch TFT LCD Module LCD Screen SPI serial 51 drivers 4 IO driver TFT Resolution 128*160 TFT interface 1.8 inch
    $2.10
    Original authentic relay EV200AAANA 1618002-7
    $29.65
    • Details
    • Reviews
    • Tags
    • FAQ
    Condition:New
    Type:Logic ICs


    Introduction to three-phase full energy parameter acquisition module



    Model: PD8073 - (xK) (xB)

    I. Overview

    Designed and manufactured for the power monitoring needs of power distribution systems. Using high-precision energy ASIC chip, it can measure active, reactive, apparent, voltage, current, frequency, power factor, four-quadrant 21st harmonic energy, double pulse output, phase sequence detection and so on. Equipped with RS485 communication interface for remote operation.

    The data type bit is a 32-bit floating point number, no conversion is required, and the MCU, Kingview, and PLC can be used directly.

    Optional alarm output, optocoupler isolated output, used to connect PLC, microcontroller. The photoelectric isolation bi-directional thyristor output can directly drive the AC contactor and has a zero-crossing trigger function.

    The module can directly replace the conventional power transmitter and is suitable for the energy efficiency management of the incoming line cabinet, generator set and base station. Can be connected to PLC, Kingview. Provide a sample of the Kingview 6.53 project.

    Everyone:
    Our advantage. We are not afraid of the goods.
    1: The power supply can be AC85-265 DC10-30V DC24-72V AC85-450V. Maybe you have to ask, why are you so many choices? The DC24-72V is used in the communication base station because the backup battery is 48V; the AC100-450V is used for phase voltage supply (no zero line), and the generally designed switching power supply cannot withstand it.

    2: Using a dedicated power chip, 24-bit sampling (floating point). Other manufacturers are generally 16-bit samples (integer).

    3: The sampling speed is fast, sampling once every cycle, 50 times per second.

    4: The data type is 32-bit floating point number, without any conversion, MCU, Kingview, PLC can be used directly. The data format of many other manufacturers is shaping, and the different variables are set to different decimal points. This is very troublesome when using Kingview and PLC. It requires different variables to be converted according to the decimal point. In short, a lot of calculations are needed.

    5: The electric energy is not lost and is permanently stored. No matter how the power-off test is conducted, there will be no loss or data confusion. Some manufacturers' products are cleared after the power is turned off. Some of them frequently lose power, and the data is confusing, and the power becomes amazing.

    5: There is phase detection function.

    6: Optical isolation 485 interface, the interface can resist AC380V access for 2 minutes without damage. Other manufacturers do not have this protection design.

    7: Optional 1 channel alarm output, 8A600V bidirectional thyristor or optocoupler output. Alarm or transmission output, all set according to the percentage of the range, the parameter structure is completely unified. The alarm output has a “hysteresis parameter” setting. His meaning is: for example, UA range 220V, upper limit alarm point 110.0%, hysteresis 5.0%, delay 2 seconds, then the action will be as follows: continuous greater than 242V for more than 2 seconds, The alarm is output; once the alarm occurs, the voltage is lower than 242-11=231V, the alarm is released.

    8: Powerful, almost all power parameters are available. The ratio of PT and CT, including electrical energy, can be processed by the meter, and the obtained data is the actual data of electricity consumption. You can also choose not to multiply.
    All other manufacturers, if the data type is a 16-bit integer, can not complete the multiplication function. For example: If CT = 120 times. 65535 stands for 65.535A, then 5A x 120=600A, which is not represented by a 16-bit integer. and so. Many manufacturers have said in the manual: to users to take their own. This also means that if the variable IA is defined in the configuration king, it is an integer type, but the actual IA is equal to (communication integer value) /1000 * CT (ratio). Ladies and gentlemen: A lot of variables have to be done this way. Very tired. For PLC multi-chip microcomputer. And we use standard floating point numbers, as long as the definition of IA is FLOAT. For details, please refer to the "Instrument King King 6.53 Project File" and "Instrument MODBUS Quick Application Guide" provided by us.

    9: Independent property rights, you can modify the program for you, and compatible with any existing system. You can guarantee that you can directly replace other manufacturers' equipment without modifying the main control program.



    Can be specified to be compatible: (requires instructions when ordering)
    1: "Jizhida" RemoDAQ-807X series register address, and is compatible with RemoDAQ-8000-9000 Series Utility software.
    The specific models are: 8073S, 8073L, 8073/B, 8073N/W
    2: "Li Chuang" EDA9011X, EDA9033X series register address, and is compatible with "E series product testing software".
    The specific models are: 9011 (A, D, E, G), 9033 (A, C), 9033_ power base can be set, 9033_ loss of pressure reported,
    9033E(C), 9033G, 9033G, 9033K, 9033 (Shida Ruifan custom)



    Second, product specifications

    PD8073 - (xK)

    Size: 35mm rail mounting



    Third, the measurement function





    Real-time data:









































































    Real-time data




    Symbol




    3-phase voltage




    UA、UB、UC




    3-phase current




    IA、IB、IC




    3-phase instantaneous active power




    PA、PB、PC




    Total active power




    PS




    3-phase instantaneous reactive power




    QA、QB、QC




    Total reactive power




    QS




    3-phase instantaneous apparent power




    SA、SB、SC




    Total apparent power




    SS




    3-phase power factor




    PFA、PFB、PFC




    Total power factor




    PFS




    3-phase phase angle




    ¢A、¢B、¢C




    Three-wire voltage




    Uab、Ubc、Uca




    Grid frequency




    F




    Voltage reverse phase sequence indication




    Ubca




    Capacitive and emotional indication




    RCLED、RLLED










    Energy data:










































    Energy data




    Symbol




    Total active and total reactive energy




    EP、EQ




    Total positive and negative active energy




    EPPS、EPNS




    Total positive and negative reactive energy




    EQPS、EQNS




    A, B, C phase positive active energy




    EPPA、EPPB、EPPC




    A, B, C reverse active energy




    EPNA、EPNB、EPNC




    A, B, C phase positive reactive energy




    EQPA、EQPB、EQPC




    A, B, C reverse reactive energy




    EQNA、EQNB、EQNC














































    Optional function:


















    Alarm outputK




    optionalDO1




    Transmitting outputB




    optionalAO1





    Fourth, other technical parameters

    Accuracy level

    Accuracy class, start performance, creep control, pulse group characteristics:

    Meet the relevant requirements of GB/T17883, GB/T17215, GB/T 17882.

    Instantaneous amount: ±0.5%

    Frequency: ±0.06Hz

    Power factor: ±0.001PF

    Power error: +0.1 - +0.2 (can be pre-adjusted according to user requirements)

    Technical performance

    Pulse constant: specific to specifications

    Voltage specifications: 220V, 57.7V, 380V, 100V, 500, 700V

    Current specifications: 5A, 30A, 60A, 120A, 250A, 400A, 1000A

    Switching output: optocoupler isolated output or opto-isolated, bidirectional thyristor output (8A 600V).

    Switch output object: Any one of the instantaneous quantities can be specified as an output object.

    Communication module: isolated RS485

    Voltage impedance: 2200K – 3300K (varies with voltage specifications)

    Current access mode: transformer access.

    Linearity range: 2 times the voltage range and 2 times the current range

    Isolation withstand voltage: greater than 2KV between all isolated ports

    Working environment: temperature -32 ° C -70 ° C relative humidity less than 90% non-corrosive gas

    Working power supply: Optional power supply type: AC 85V-265V (default type) / DC 8V-30V (specify when ordering) /DC 32-72V (communication base station 48V power supply) / AC100-450V (phase power supply)

    Real-time clock function: Bring your own lithium battery, no loss after 5 years of power failure

    Total power consumption: less than 1W