Model Number:EAZY-V3
Type:Logic ICs
Condition:New
Relay Type:Electromagnetic relays
Applicable:Appliances with relay
Can choose:12V and 24V,default 12V


EAZY-V3 voltage relays , digital DC voltage detection, control relay output, limit 0-99.9V adjustable voltage can be set to exceed the upper limit relay, broken below the lower limit can also be set lower than limit relay, higher than the upper limit disconnect switch can be used as a voltage detection , battery over-voltage protection , charge and discharge time use .
The relay control board isSingle -mode voltage detection controlIf you need to add delay function voltage detector combination , as well as multi-function mode , you can select shop EAZY-RL VT2.3 version , more powerful .item.taobao.com/item.htm?spm=686.1000925.1000774.36.62BSJI&id=16640484933
The relay load contacts have three contacts ( one group conversion ) : common point , normally closed , normally open ,Contact Maximum current 10A ( AC 277V DC 30V)When the relay is not energized , the relay is released , the common point and normally closed switched on , when the relay coil is energized relay, common and normally open points will be connected . Relay contact is equivalent to the switch, the wiring should be in series with the load power circuit , not short-circuit the power supply connection .
Negative and negative power supply voltage detection input is common ground connectedIf the detected voltage and power is the same power , voltage detection of negative line may not be connected .
Features a simple operation, the operator shall set the following picture formats manual . Save the following captions , or download an electronic version of the specification :pan.baidu.com/s/1mgG8lzM.
English manual download EAZY-V3 Controller User's Manual:pan.baidu.com/s/1hqnAcb6

1 .Performance Parameters
Voltage detection display range : 0 ~ 99.9V voltage detection error : 0.1V;
Power supply : DC 10 ~ 16V (5V version working power for DC5 ~ 9V);
Operating Current : Standby average 16mA / 12V, relay timely 45mA / when 12V, digital tube off standby current 6mA / 12V;
Relay parameters: a set of conversion ( normally open normally closed )
Contact load :10A/ 277VAC 10A / 30 DC Note maximum 30V 10A DC load
Mechanical Durability: > 10 million times
Electrical Durability: > 100,000 times (10A-250VAC)
Working temperature : -40 ~ 85
Plug -in digital control, digital control can be set to automatically turn off (0 ~ 9 Min);
Timely relay automatically starts counting by the minute , 0~999 minutes cycle.
Setting parameters can be powered down to save for 30 years


20,140,708 new version of the date of shipment timing function , that is, when the relay timely start time, the default display digital detection voltage , short press the ENTER key to toggle the display of the relay continued pull- minute time (0-999Min increments ) , when the relay when released, the time to stop and hold the display , clear weight again when the relay pulls in accounting, timekeeping cleared long press ETNER button for three seconds or heavy power relay board . This feature can be used to charge or discharge the battery time ( note the use of an external relay non- constant load discharge discharge discharge ) .

Control the charging and load circuit switching , negative total , the switching positive