Price:   $27.88

  • Model: ic0A547
  • Shipping Weight: 0.2kg
  • 9999 Units in Stock

(0 reviews)

Please Choose:

  • standard
  • Optical isolated
(complete orders today,deliverd around 11/07/2024)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    G12 thread electronic probe filter temperature and humidity sensor protective cover protective sleeve SHT10 SHT11 SHT15 SHT75
    $46.58
    XL4015 TO2635A 180 kHz 36V Buck DC to DC Converter
    $0.44
    Making 0.1X400 shares high frequency line multi strand wire USTC litz wire
    $34.65
    Pluggable ATTINY Development Board For ATtiny13AATtiny25ATtiny45ATtiny85 Programming Editor Micro Usb Power Connector
    $4.41
    • Details
    • Reviews
    • Tags
    • FAQ
    Dissipation Power:W
    Operating Temperature:C
    Supply Voltage:V
    Type:Logic ICs
    Condition:New
    Application:0

    A,Summary:

    XKC-C352High and low liquid level controllerCan andXCK-Y26Non contact typeThe liquid level sensor with the use, can also be combined with other floating ball liquid level sensor used to achieve the liquid level of a container is too little by the liquid level sensor low liquid level alarm signal emitted when the pump starts automatically with the liquid level, the liquid level reaches a certain height high level sensor signal automatically stops the pump work, so as to realize the container liquid level automatic control function.The controller self protection ability with the pump to stop pumping air detection, high overflow detection, flush timeout detection; manual mode control can control various pumps, can also control the water pump automatic mode; multiple output mode, a load output control power up to1600W, all the way alarm output control up to800W, there are normally open relay output, but also to exchange110Vor220VOutput. The controller function set is complete, suitable for a wide range of applications.

    Two,Characteristic:

    1The compatibility and the use of a variety of liquid level sensor input control;

    2And protection ability, with waterproof protection and water pump idle overflow detection with output.4Hours overtime pumping alarm;

    ThreeRelay output, can be applied to a variety of load control;

    4Control of diversification, can be manual or automatic mode control pump;

    FiveThe installation is simple and convenient, and can be positioned and installed with screws, and can also be installed in the electric box;

    ThreeElectrical parameters:

    Model

    XKC-C352V2

    Name

    C352Automatic controller for high and low liquid level

    inputVoltage

    AC100V-220V,50/60Hz

    working voltage

    DC12V

    Operating current

    The working current is less than or equal to110 mAStatic current consumption is less than or equal.20mA

    Load power

    1.6KWThe following (overload or for three-phase water pump need to install AC contactor)

    Alarm output

    800W(resistive load) normally open normally closed output

    Output mode

    Relay normally open normally closed or ACAC110V/220Vtwo types2Select one output

    Input signal

    Low signal input;

    High induction signal transmission;

    Induced head interface voltage

    DC 12V

    working temperature

    -10~75C

    Outline dimension

    115*90*40

    Signal input and relay output:

    Input signal

    Load output

    Alarm signal state

    Alarm output

    Low order0, high as0

    Normally open and close, normally closed.

    Robin

    ring

    Low order0, high as1

    Normally open and close, normally closed.

    Low order1, high as0

    Normally open and close, normally closed.

    High overflow1

    Normally open and close, normally closed.

    Low order1, high as1

    Normally open, normally closed

    Call the policeState,Load output: normally open, normally closed

    (relay off state, load off to protect)

    Low order1, high as0

    Normally open, normally closed

    Four,Basic function introduction:

    1.Automatic control of water level:The water level is lower than the low position induction probe, the automatic start water pump, the water level rises to the high position, the automatic closing the water pump.

    2.Pump timeout protection:Continuous automatic pumping more than5Automatic stop pump. Work indicator light flashes quickly, can pressK2Key to stop, or automatic delay recovery.

    3.Manual automatic switching:The controller is started by default into the automatic mode of operation.K1Key to switch the working mode, the red light is automatic mode, the red light is used as the manual mode.

    4.Non contact inductive probe: Non contact capacitive sensing technology and dedicated induction control chip design, the probe has a durable, strong anti-interference ability, sensitive, not in contact with liquid, corrosion resistance, safety and environmental protection without pollution.