Brand Name:icchipcn.com
Condition:New
Type:Voltage Regulator
Model Number:Voltmeter Ammeter
Supply Voltage:AC Ammeter
Dissipation Power:Ammeter
is_customized:Yes
Operating Temperature:LED Digital Display
Application:AC100-265V
Package:AC Voltmeter
Type:Ammeter Power Consumption
Description:
1. Electrical parameter measurement function (voltage, current, power, electricity quantity, timing, power factor, frequency, temperature)
2. Voltage alarm function (voltage alarm threshold, voltage display value and backlight flash, buzzer alarm prompt, 30 seconds)
3. Current alarm function (current alarm threshold, current display value and backlight flash, buzzer alarm prompt, 30 seconds)
4. Power failure data saving function
5. Backlight function
6. Timing function
7. Temperature function
Model 9050-6AL (20A) Model 9050-6AH (100A) Parameters and specifications:
Voltage:
Test range AC100-265V AC100-265V
Display format 100-265V 100-265V
Electric current:
Test range 0-20A 0-100A
Display format 0.01-19.9A 0.01-99.9A
Power:
Test range 0-1999kW 0-1999kW
Display format within 2kW 0.1-1999W 0.1-1999W
Display format above 2kW 2.00-10.00kW 2.00-50.0kW
Test range 0.1-1999KWh 0.1-1999KWh
Power:
Display format within 2KWh 0.1-1999Wh 0.1-1999Wh
Display format above 2KWh 2.00-1999KWh 2.00-1999KWh
Time range 0-199 hours 0-199 hours
Time:
Timing display format 199.59 hours/minute 199.59 hours/minute
Temperature detection range - 10 ° to 70 ° - 10 ° to 70 °
Frequency:
Display format - 10 ° to 70 ° - 10 ° to 70 °
Detection range 40Hz to 70Hz 40Hz to 70Hz
Display format 50Hz 50Hz
Power factor:
Detection range 0-1 0-1
Display format 0.01-1.00 0.01-1.00
1. Backlight control:
The backlight can be turned on or off by briefly pressing the key.
2. Voltage alarm setting:
Step 1: Press and hold the key for 3 seconds on the main page to enter the setting page (one sound of BI), and SET is displayed. Press and hold the key for another 3 seconds to enter the 00.0V voltage alarm setting (display the value saved for the last setting), and press the key briefly to switch submenus: such as reset of SET voltage, SET current, SET electricity, and SET timing; In the voltage alarm setting state, long press the key for 1.5 seconds and the first value of the voltage flashes to enter the voltage alarm setting state.
Step 2: Each short press of the key increases the value by one number, and then long press the key for 1.5 seconds to enter the second digit setting. Short press to change the value. After the voltage alarm value is set, long press the key for 3 seconds to save the value (the value is always on). At this time, short press the key to change the submenu setting page. If the key is not pressed within 6 seconds, It will automatically save the last value and return to the main page (the buzzer will sound BI to remind you to return to the main page).
3. Current alarm setting:
Step 1: On the main page, press and hold the key for 3 seconds to enter the setting page (one sound of BI), and the SET 00.0V voltage alarm setting is displayed (the value saved for the last setting is displayed). Short press the key to switch submenus: such as reset of SET voltage, SET current, SET electric quantity, and reset of SET timing; In the current alarm setting state, long press the key for 1.5 seconds and the first value of the voltage flashes to enter the current alarm setting state.
Step 2: Each short press of the key increases the value by one number, and then long press the key for 1.5 seconds to enter the second digit setting. Short press to change the value. After the current alarm value is set, long press the key for 3 seconds to save the value (the value is always on). At this time, short press the key to change the submenu setting page. If the key is not pressed within 6 seconds, It will automatically save the last value and return to the main page (the buzzer will sound BI to remind you to return to the main page).
4. Setting of electricity clearing:
Step 1: On the main page, press and hold the key for 3 seconds to enter the setting page (one sound of BI), and the SET 00.0V voltage alarm setting is displayed (the value saved for the last setting is displayed). Short press the key to switch submenus: such as reset of SET voltage, SET current, SET electric quantity, and reset of SET timing; In the state of electricity reset setting, long press the key for 1.5 seconds and the electricity value flashes, and then long press the key for 3 seconds to complete the electricity reset (the reset is always on when the BI is synchronized with the reset); At this time, you can briefly press the key to switch to the submenu setting page. If you do not press the key within 6 seconds, the last value will be saved automatically and return to the main page (the buzzer will sound BI to remind you to return to the main page).
5. Timing reset setting:
Step 1: On the main page, press and hold the key for 3 seconds to enter the setting page (one sound of BI), and the SET 00.0V voltage alarm setting is displayed (the value saved for the last setting is displayed). Short press the key to switch submenus: such as reset of SET voltage, SET current, SET electric quantity, and reset of SET timing; In the timing reset setting state, long press the key for 1.5 seconds and the timing value flashes, and then long press the key for 3 seconds to complete the timing reset (a sound of resetting and synchronizing BI, and the reset value is always on); At this time, you can briefly press the key to switch to the submenu setting page. If you do not press the key within 6 seconds, the last value will be saved automatically and return to the main page (the buzzer will sound BI to remind you to return to the main page).
Package Contents:
9050-6AL 20A meter head * 1
9050-6AH 20A meter * 1+transformer * 1
Only the above package content, other products are not included.
Note: Light shooting and different displays may cause the color of the item in the picture a little different from the real thing. The measurement allowed error is +/- 1-3cm.