DC 5V Real time Timing Delay Timer Relay Module Switch Control Clock Synchronization Multiple mode control Wiring diagram
DC 5V Real time Timing Delay Timer Relay Module Switch Control Clock Synchronization Multiple mode control Wiring diagram
DC 5V Real time Timing Delay Timer Relay Module Switch Control Clock Synchronization Multiple mode control Wiring diagram
DC 5V Real time Timing Delay Timer Relay Module Switch Control Clock Synchronization Multiple mode control Wiring diagram

DC 5V Real time Timing Delay Timer Relay Module Switch Control Clock Synchronization Multiple mode control Wiring diagram

Price:   $3.20

  • Model: icchipcn0007304
  • Shipping Weight: 0.1kg
  • 9999 Units in Stock

(0 reviews)
(complete orders today,deliverd around 26/04/2025)
  • Shipping time
    Shipping Worldwide.About 5-15 days.
  • means of transportation
    EMS,DHL,FEDEX,HK Post
  • Payment
    Paypal,T T,
  • Email us
    [email protected]
  • New Products
    10PCS K2129 2SK2129 TO-220F 800V 3A
    $4.50
    DC 12V PWM Speed Controller Fan Speed governor 4 Wire Computer Temperature control Switch For PC CPU Cooler Fan Alarm STK IC
    $5.21
    100%New ALC3240 ALC3241 ALC3242 ALC3245 ALC3246 ALC3248 ALC3661 ALC5672 QFN
    $4.00
    Load cell digital signal conversion device PLC MCU computer 485 communication High-speed AD module
    $98.96
    • Details
    • Reviews
    • Tags
    • FAQ
    Brand Name:icchipcn.com
    Condition:New
    Type:Voltage Regulator
    Application:Computer
    Supply Voltage:1
    Dissipation Power:1
    is_customized:Yes
    Description:
    Real-time relay timing and clock synchronization time control delay 24H timing 5 time periodsProduct Highlights:Wide voltage power supply 5.0V ~ 60V;
    A mode can be set for multiple time periods, can reach 5 time periods;
    With a buzzer alarm function.Mode introduction:OPE: relay closing time point, CLE: relay off time point
    Time period: PE-1 ~ PE-5 5 time periods (OPE to CLE is a time period)
    ----: function shieldingP-1: The relay closes or outputs pulses every day to the OPE time point, and the relay turns off or outputs pulses to the CLE time point.P-2: set the day, to the OPE time point when the relay closed or output pulse, to the CLE time point when the relay disconnect / or output pulseP-3: set the date of the month, to the OPE time point when the relay closed or output pulse, to the CLE time point when the relay is off or output pulseP-4: Set the date 1 to date 2, start every day at the OPE time point, end to the CLE time point, relay action or output pulseP-5: As with P-4, only the month can not be setFirst, how to set the time In the time to run the interface, press the DOWN button for a while:Step 1: Select the time period: PE-1 ~ PE-5 Press UP and DOWN to select;Step 2: Press the SET key to select the mode: P-1 ~ P-5 (Set this time period to the corresponding mode) by pressing the UP and DOWN keys. ("----" means to block this time period)Note: Each time period can be repeated from the "----", P-1 ~ P-5 one of the optional; For example,you can let five time periods at the same time work in the P-1 mode, or let Time period 1 work in P-1 mode, time period 2 work in P-2 mode and so on.Step 3: After the mode selection is finished, press the SET key to enter the time period setting interface, set the interface in the time period, press the SET key to switch the parameter, "OPE" start time point, "CLE" end point, "dAE" date information;Step 4: After setting the parameters to exit the settings, press the SET button for 2 seconds to release, automatically check whether the parameter settings are legal, legal to save the parameters, return to the time to run the interface; if the parameter is wrong, "ERR" reminder (for example, stop time or Date <= start time or date), return to the parameter setting interface;
    Additional features: Each "time period" can be set individuallyIn the specific parameter setting interface (after the second step), press the STOP button to switch the output mode:OUT1: Start time point turns on the relay, the end time is off the relayOUT2: Outputs 1S pulse to start or end timeIn the specific parameter setting interface (after the second step), press the STOP button for a while to switch the ringing mode:BLL0: Ring disableBLL1: Ring enableNote: When the bell rings, press any button to stop the ringSTOP key function expansion:
    Relay enable mode:1. ON: enable relay on;2. OFF: Do not turn on the relay, it is always off;
    Press the STOP button on the time display interface to switch between ON and OFF, the current status will flash, and then return to the main interface. (This function is the emergency stop function, press once to close the closed relay)After the relay is disabled, the product can be used as an alarm clock.Sleep mode:1. C-P sleep mode: within five minutes, without any operation, the digital tube automatically shut down the display, the program normal operation;2. O-d normal mode: digital tube is always open display;
    Press the STOP button for a while after 2 seconds to release, to achieve C-P and O-d state of the switch, the current state will flash, and then return to the main interface.